1SDA063070R1 ABB T7L 1600 PR332/P-LSI 1600 A 4-Pole MCCB

1SDA063070R1 ABB T7L 1600 PR332/P-LSI 1600 A 4-Pole MCCB

ABB 1SDA063070R1 T7L 1600 is a 1600 A four-pole fixed moulded case circuit breaker with a PR332/P-LSI electronic trip unit and 120 kA breaking capacity at 380–415 V AC for high-current low-voltage power distribution.

SKU: 1SDA063070R1MPN: 1SDA063070R1
Price
List Price £19,425.16 ex VAT
Your Price (ex VAT) Save 25%
£14,568.87 25% OFF
You save £4,856.29 per unit
Manufacturer Lead Time Estimated Delivery 10 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £14,568.87
Trade pricing is personalised to your account

Manufacturer Lead Time

£14,568.87

Why Choose the ABB 1SDA063070R1 T7L 1600 Circuit Breaker?

The ABB 1SDA063070R1, extended product type T7L 1600 PR332/P LSI In=1600A 4p F F, is a high-performance moulded case circuit breaker (MCCB) designed for protection and switching in demanding low-voltage electrical distribution systems. Part of the ABB SACE Tmax T7 series, it combines a 1600 A rated uninterrupted current, four-pole construction and a PR332/P-LSI electronic trip unit.

The PR332/P-LSI electronic release provides long-time overload, short-time delayed short-circuit and instantaneous short-circuit protection. This combination enables protection characteristics to be coordinated with downstream circuits while providing rapid interruption of severe faults, making the breaker suitable for high-current incomers, feeders and distribution circuits.

The T7L 1600 provides a rated ultimate short-circuit breaking capacity of 120 kA at 380–415 V AC and operates at voltages up to 690 V AC. This version is supplied as a fixed four-pole breaker with front terminals, providing a robust solution for industrial switchboards, infrastructure and high-capacity power distribution assemblies.

Key Advantages

  • High-performance ABB SACE Tmax T7L moulded case circuit breaker for demanding low-voltage power distribution.
  • 1600 A rated uninterrupted current for high-current electrical systems.
  • Four-pole construction for three-phase four-wire distribution applications.
  • 120 kA ultimate breaking capacity at 380–415 V AC for networks with high prospective fault currents.
  • Advanced PR332/P-LSI electronic trip unit for configurable overload and short-circuit protection.
  • Long-time, short-time delayed and instantaneous protection functions support effective protection coordination.
  • 20 kA for 1 s short-time withstand current supports selective distribution system design.
  • Fixed configuration with front terminals for integration into low-voltage switchboards and distribution assemblies.

Key Features

  • ABB SACE Tmax T7L 1600 series MCCB.
  • 1600 A rated uninterrupted current.
  • Four-pole construction.
  • PR332/P-LSI electronic release.
  • Long-time overload protection.
  • Short-time delayed short-circuit protection.
  • Instantaneous short-circuit protection.
  • 120 kA Icu at 380–415 V AC.
  • Breaking capacity up to 200 kA at 220–230 V AC.
  • 690 V AC rated operational voltage.
  • 1000 V rated insulation voltage.
  • 8 kV rated impulse withstand voltage.
  • 20 kA for 1 s rated short-time withstand current.
  • Fixed circuit breaker installation.
  • Front terminals for main circuit connections.

Selective Protection for High-Current Power Distribution

Moulded case circuit breakers such as the ABB Tmax T7L protect low-voltage electrical distribution systems against excessive currents caused by overload and short-circuit conditions. The four-pole construction makes the 1SDA063070R1 suitable for three-phase four-wire distribution systems where four-pole switching is required.

The PR332/P-LSI electronic trip unit combines long-time overload protection with short-time delayed and instantaneous short-circuit protection. Together with the 120 kA breaking capacity at 380–415 V AC and 20 kA for 1 s short-time withstand capability, the breaker is well suited to high-current networks where protection coordination and dependable fault interruption are important.

Typical Applications

  • Main and sub-main low-voltage distribution boards.
  • Three-phase four-wire electrical distribution systems.
  • Industrial switchboards and power distribution assemblies.
  • Main incomers and high-current feeder circuits.
  • Manufacturing and process plants.
  • Commercial and infrastructure power distribution.
  • Transformer secondary and feeder protection.
  • Electrical networks requiring coordinated short-time and instantaneous protection.
  • Installations with high prospective short-circuit currents.

Technical Specifications

Series SACE Tmax T7
ABB product group 310511-T-Max T4 - T8
Order code 1SDA063070R1
EAN 8015644656195
Product type Moulded case circuit breaker (MCCB)
Breaker type T7L 1600
Rated uninterrupted current (Iu) 1600 A
Number of poles 4
Trip unit PR332/P-LSI electronic release
Release type Electronic
Protection functions Long-time overload, short-time delayed short-circuit and instantaneous short-circuit protection
Rated operational voltage 690 V AC
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 8 kV
Ultimate breaking capacity (Icu) at 220–230 V AC 200 kA
Ultimate breaking capacity (Icu) at 380–415 V AC 120 kA
Ultimate breaking capacity (Icu) at 440 V AC 100 kA
Ultimate breaking capacity (Icu) at 500 V AC 85 kA
Ultimate breaking capacity (Icu) at 690 V AC 50 kA
Service breaking capacity (Ics) at 220–230 V AC 200 kA
Service breaking capacity (Ics) at 380–415 V AC 120 kA
Service breaking capacity (Ics) at 440 V AC 100 kA
Service breaking capacity (Ics) at 500 V AC 64 kA
Service breaking capacity (Ics) at 690 V AC 37.5 kA
Rated short-time withstand current (Icw) 20 kA for 1 s
Power loss at rated conditions 77 W per pole
Installation version Fixed
Terminal position Front
Standard IEC

Frequently Asked Questions

What is the ABB 1SDA063070R1 used for?

The ABB 1SDA063070R1 is a 1600 A four-pole moulded case circuit breaker designed for switching and protection of high-current low-voltage electrical distribution circuits against overload and short-circuit conditions.

What is the current rating of the ABB T7L 1600 1SDA063070R1?

The circuit breaker has a rated uninterrupted current of 1600 A, making it suitable for high-capacity incomers, feeders and power distribution circuits.

What breaking capacity does the ABB T7L 1600 1SDA063070R1 provide?

The breaker provides a rated ultimate short-circuit breaking capacity of 120 kA at 380–415 V AC, with a capacity of up to 200 kA at 220–230 V AC.

What trip unit is fitted to the ABB 1SDA063070R1?

The breaker is fitted with an ABB PR332/P-LSI electronic trip unit, providing long-time overload, short-time delayed short-circuit and instantaneous short-circuit protection.

Is the ABB 1SDA063070R1 a four-pole circuit breaker?

Yes. The 1SDA063070R1 is a four-pole fixed circuit breaker with front terminals, making it suitable for high-current three-phase four-wire power distribution systems requiring four-pole switching.

Trusted by Electrical Professionals Worldwide

ABB SACE Tmax moulded case circuit breakers are widely used in industrial, commercial and infrastructure power distribution systems where dependable electronic protection, high breaking capacity and configurable protection characteristics are required.