1SDA063064R1 ABB T7L 1600 PR332/P LSIRc In=1600A 3p Moulded Case Circuit Breaker

1SDA063064R1 ABB T7L 1600 PR332/P LSIRc In=1600A 3p Moulded Case Circuit Breaker

ABB T7L 1600 PR332/P LSIRc circuit breaker, a 1600 A three pole Tmax T moulded case circuit breaker designed for reliable low voltage electrical distribution protection.

SKU: 1SDA063064R1MPN: 1SDA063064R1
Price
List Price £16,921.60 ex VAT
Your Price (ex VAT) Save 25%
£12,691.20 25% OFF
You save £4,230.40 per unit
Manufacturer Lead Time Estimated Delivery 10 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £12,691.20
Trade pricing is personalised to your account

Manufacturer Lead Time

£12,691.20

Why Choose the ABB T7L 1600 PR332/P LSIRc In=1600A 3p Moulded Case Circuit Breaker?

The ABB T7L 1600 PR332/P LSIRc In=1600A 3p is a high-performance moulded case circuit breaker (MCCB) designed for reliable protection and switching in demanding low-voltage electrical distribution systems. Part of the advanced ABB SACE Tmax T7 series, this three-pole circuit breaker combines robust construction with the electronic PR332/P-LSIRc trip unit for comprehensive long-time, short-time, instantaneous and residual current protection.

Developed for industrial and infrastructure power applications, the T7L 1600 provides accurate protection adjustment, dependable circuit interruption and reliable operation in complex electrical installations. The advanced electronic release supports improved fault detection and selective coordination within modern distribution networks.

With a rated current of 1600 A, a three-pole configuration and a rated operational voltage of 690 V AC, the ABB T7L 1600 PR332/P LSIRc is suitable for high-capacity electrical systems requiring advanced protection and dependable short-circuit performance.

Key Advantages

  • 1600 A rated current capacity for high-power low-voltage distribution systems.
  • ABB Tmax T7 MCCB technology for dependable industrial circuit protection.
  • PR332/P-LSIRc electronic trip unit providing long-time, short-time, instantaneous and residual current protection.
  • Three-pole configuration for three-phase electrical distribution applications.
  • Advanced electronic protection improves system safety and coordination.
  • Reliable ABB construction for long service life and consistent operation.

Key Features

  • ABB SACE Tmax T7 series moulded case circuit breaker.
  • 1600 A rated uninterrupted current.
  • Three-pole (3P) configuration.
  • PR332/P-LSIRc electronic release.
  • Long-time (L), short-time (S), instantaneous (I) and residual current (Rc) protection functions.
  • Advanced electronic settings for selective protection coordination.
  • Designed for industrial low-voltage electrical distribution applications.
  • Compact MCCB construction for switchboard installation.

Reliable Protection for Industrial Power Distribution

Moulded case circuit breakers such as the ABB T7L 1600 protect electrical installations by monitoring current conditions and disconnecting circuits during overload, short-circuit or residual current fault events. This helps safeguard cables, switchgear and connected equipment from electrical damage.

The Tmax T7 platform combines compact MCCB construction with advanced electronic protection technology. The PR332/P-LSIRc release provides accurate fault monitoring and supports reliable coordination within modern industrial distribution networks.

Typical Applications

  • Industrial power distribution switchboards.
  • Main incomer and feeder protection systems.
  • Manufacturing plants and production facilities.
  • Motor control centres and electrical panels.
  • Transformer and generator protection applications.
  • Commercial and infrastructure electrical systems.

Technical Specifications

Series SACE Tmax T7
Order code 1SDA063064R1
Product type Moulded case circuit breaker
Rated current (In) 1600 A
Number of poles 3P
Rated operational voltage 690 V AC
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 8 kV
Trip unit PR332/P-LSIRc electronic release
Protection functions Long-time, short-time, instantaneous and residual current protection
Mounting version Fixed
Terminal connection Front terminals
Protection rating IP20

Frequently Asked Questions

What is the ABB T7L 1600 PR332/P LSIRc used for?

This ABB Tmax T7 circuit breaker is used for protecting and switching high-capacity low-voltage electrical distribution systems.

What is the rated current of this circuit breaker?

The ABB T7L 1600 PR332/P LSIRc has a rated current of 1600 A.

How many poles does the ABB T7L 1600 have?

The circuit breaker has a three-pole (3P) configuration for three-phase electrical distribution applications.

Which trip unit is installed on this breaker?

The breaker is fitted with the PR332/P-LSIRc electronic trip unit, providing long-time, short-time, instantaneous and residual current protection functions.

Where is the ABB T7L 1600 typically installed?

The T7L 1600 is typically installed in industrial switchboards, distribution panels and high-capacity electrical power systems.

Trusted by Electrical Engineers Worldwide

ABB Tmax T circuit breakers are widely used in industrial and commercial power systems to provide reliable protection, efficient switching and dependable electrical distribution management.