1sda063015r1  t7s 1600 pr332/p lsig in=1600a 3 pole abb mccb

1sda063015r1 t7s 1600 pr332/p lsig in=1600a 3 pole abb mccb

ABB 1SDA063015R1 Tmax T7S 1600 moulded case circuit breaker with PR332/P LSIG electronic release, 1600 A rated current, fixed three-pole construction and front terminals for industrial low-voltage circuit protection.

SKU: 1SDA063015R1Alt SKU: T7S 1600 PR332/P LSIG In=1600A 3p F F MMPN: 1SDA063015R1
Price
List Price £13,399.41 ex VAT
Your Price (ex VAT) Save 25%
£10,049.56 25% OFF
You save £3,349.85 per unit
Manufacturer Lead Time Estimated Delivery 10 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £10,049.56
Trade pricing is personalised to your account

Manufacturer Lead Time

£10,049.56

Why Choose the ABB 1SDA063015R1 Tmax T7S 1600 MCCB?

The ABB 1SDA063015R1 is a high-performance Tmax T7S 1600 moulded case circuit breaker designed for reliable protection in low-voltage power distribution systems. As part of the proven ABB SACE Tmax T circuit breaker range, it provides robust circuit protection for industrial switchgear, commercial distribution boards and high-current electrical installations.

This circuit breaker is supplied as a fixed three-pole MCCB with front terminals, a stored energy operating mechanism and a PR332/P LSIG electronic release. The LSIG protection functions provide long-time, short-time, instantaneous and earth fault protection, supporting accurate fault discrimination and improved system safety.

With a rated uninterrupted current of 1600 A and a rated operational voltage of up to 690 V AC, the ABB 1SDA063015R1 is ideal for main incomers, feeder circuits, motor control centres and high-capacity switchboards requiring dependable protection and strong short-circuit performance.

Key Advantages

  • High-capacity ABB Tmax T7S moulded case circuit breaker for industrial power protection.
  • 1600 A rated current suitable for main distribution and feeder circuits.
  • Three-pole fixed construction for low-voltage switchgear systems.
  • PR332/P LSIG electronic trip unit for adjustable overload, short-circuit and earth fault protection.
  • Front terminal design for straightforward switchboard installation.
  • Stored energy operating mechanism for reliable switching performance.

Key Features

  • ABB SACE Tmax T7S circuit breaker series.
  • 1600 A rated uninterrupted current.
  • 3-pole moulded case circuit breaker.
  • Fixed installation version.
  • Front terminal connection type.
  • PR332/P LSIG electronic release.
  • Rated operational voltage up to 690 V AC.
  • Short-circuit performance level S.

Reliable Protection for High-Current Electrical Systems

Moulded case circuit breakers such as the ABB Tmax T7S 1600 are used to protect electrical installations against overloads, short circuits and earth faults. The ABB 1SDA063015R1 combines a robust high-current breaker frame with electronic protection, helping improve safety, continuity and fault discrimination in low-voltage distribution networks.

The PR332/P LSIG electronic trip unit provides adjustable long-time, short-time, instantaneous and earth fault protection functions. This makes the MCCB suitable for systems where selective coordination, accurate protection settings and reliable circuit isolation are required.

Typical Applications

  • Main low-voltage distribution boards.
  • Industrial switchgear and panel building.
  • Feeder circuit protection.
  • Motor control centres and process plants.
  • Commercial building power distribution.
  • Infrastructure, utilities and energy systems.

Technical Specifications

Tick the specs you need, then view products that match.

Current 1600 A
Phase Three Phase
Poles 3-pole
Device Type MCCB
Breaking Capacity 50 kA
Trip Unit Electronic
Manufacturer ABB
Series SACE Tmax T
Model T7S 1600 PR332/P LSIG In=1600A 3p F F M
Product ID 1SDA063015R1
Product type Moulded case circuit breaker
Rated current 1600 A
Rated uninterrupted current 1600 A
Number of poles 3P
Release PR332/P LSIG
Release type Electronic / solid-state
Protection functions LSIG
Installation type Fixed
Terminal type Front terminals
Rated operational voltage 690 V AC
Rated insulation voltage 1000 V
Rated impulse withstand voltage 8 kV
Rated service short-circuit breaking capacity 50 kA at 415 V AC
Rated ultimate short-circuit breaking capacity 50 kA at 415 V AC
Rated short-time withstand current 20 kA for 1 s
Electrical durability 2000 cycles
Mechanical durability 10000 cycles
Short-circuit performance level S
Standards IEC
Dimensions (H × W × D) approx. 268 × 210 × 178 mm
Weight approx. 11 kg
EAN 8015644655648

Frequently Asked Questions

What is the ABB 1SDA063015R1 used for?

The ABB 1SDA063015R1 is used to protect high-current low-voltage electrical circuits against overloads, short circuits and earth faults in industrial and commercial power distribution systems.

What current rating does this circuit breaker have?

This ABB Tmax T7S circuit breaker has a rated current of 1600 A.

What trip unit is fitted to this MCCB?

The breaker is fitted with a PR332/P LSIG electronic release, providing long-time, short-time, instantaneous and earth fault protection functions.

How many poles does the ABB 1SDA063015R1 have?

The ABB 1SDA063015R1 is a three-pole moulded case circuit breaker.

Where is this circuit breaker typically installed?

It is typically installed in low-voltage switchboards, main distribution panels, feeder circuits, motor control centres and industrial electrical cabinets.

Trusted by Electrical Engineers Worldwide

ABB Tmax T moulded case circuit breakers are widely used by electrical engineers, panel builders and industrial facilities to deliver safe, reliable and efficient low-voltage circuit protection.