ABB 1SDA063009R1 SACE Tmax T7S 1600A four-pole moulded case circuit breaker with PR332/P-LSIG electronic trip unit for industrial low voltage power distribution.

SKU: 1SDA063009R1Alt SKU: T7S 1600 PR231/P I In=1600A 3p F F MMPN: 1SDA063009R1
Price
List Price £10,769.31 ex VAT
Your Price (ex VAT) Save 25%
£8,076.98 25% OFF
You save £2,692.33 per unit
Manufacturer Lead Time Estimated Delivery 10 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £8,076.98
Trade pricing is personalised to your account

Manufacturer Lead Time

£8,076.98

Why Choose the ABB 1SDA063009R1 Tmax T7S Moulded Case Circuit Breaker?

The ABB 1SDA063009R1 is a heavy-duty Tmax T7S moulded case circuit breaker (MCCB) designed for dependable protection of industrial low voltage power distribution systems. As part of the proven ABB SACE Tmax T7 series, this fixed four-pole circuit breaker is ideal for high-current switchboards, feeder circuits, transformer protection, generator installations and demanding industrial power distribution applications.

This model incorporates the advanced PR332/P-LSIG electronic trip unit, providing long-time, short-time, instantaneous and earth fault protection. The intelligent electronic release enables accurate fault detection, enhanced selectivity and dependable protection, helping maximise electrical system uptime while improving installation safety.

With a rated current of 1600 A, rated operational voltage up to 690 V AC and a fixed four-pole design with front terminals, the ABB 1SDA063009R1 delivers reliable protection for high-capacity industrial electrical systems.

Key Advantages

  • Heavy-duty ABB Tmax T7S moulded case circuit breaker.
  • 1600 A rated current for demanding industrial power systems.
  • PR332/P-LSIG electronic trip unit with comprehensive protection.
  • Four-pole fixed configuration with front terminals.
  • Long-time, short-time, instantaneous and earth fault protection.
  • High interrupting capacity for industrial installations.
  • Reliable lever operating mechanism.
  • Suitable for switchboards, feeders, transformers and generator protection.

Key Features

  • ABB SACE Tmax T7S series.
  • 1600 A rated uninterrupted current.
  • Four-pole MCCB.
  • PR332/P-LSIG electronic release.
  • Fixed execution with front terminals.
  • Rated operational voltage up to 690 V AC.
  • Rated insulation voltage of 1000 V.
  • Rated impulse withstand voltage of 8 kV.
  • Manufactured to IEC 60947-2.

Reliable Protection for Industrial Power Distribution

The ABB Tmax T7S range provides dependable protection against overloads, short circuits and earth faults while supporting reliable operation of industrial electrical infrastructure. The PR332/P-LSIG trip unit enables advanced protection coordination for improved selectivity and reduced downtime.

Its robust four-pole construction and front terminal arrangement make it suitable for installation within industrial switchboards, motor control centres and main distribution assemblies where dependable protection is essential.

Typical Applications

  • Main low voltage distribution boards.
  • Industrial switchboards.
  • Power distribution panels.
  • Transformer protection.
  • Generator protection.
  • Manufacturing facilities.
  • Commercial buildings.
  • Infrastructure and utilities.

Technical Specifications

Tick the specs you need, then view products that match.

Current 1600 A
Phase Three Phase
Poles 4-pole
Device Type MCCB
Breaking Capacity 85 kA
Trip Unit Electronic
Manufacturer ABB
Series SACE Tmax T7S
Part number 1SDA063009R1
Extended product type T7S 1600 PR332/P LSIG In=1600A 4p F F
Product type Moulded Case Circuit Breaker
Rated current (In) 1600 A
Rated uninterrupted current (Iu) 1600 A
Number of poles 4P
Rated operational voltage Up to 690 V AC
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 8 kV
Trip unit PR332/P-LSIG
Release type Electronic
Protection functions LSIG
Short-circuit performance level S
Rated ultimate breaking capacity (Icu) 85 kA at 230 V AC, 50 kA at 400 V AC, 40 kA at 500 V AC, 30 kA at 690 V AC
Rated short-time withstand current (Icw) 20 kA for 1 second
Mounting type Fixed
Terminal connection Front terminals
Operating mechanism Lever operated
Standard IEC 60947-2
Dimensions (H × W × D) approx. 268 × 280 × 154 mm
Weight approx. 12.5 kg

Frequently Asked Questions

What is the ABB 1SDA063009R1 used for?

It protects industrial low voltage electrical systems against overloads, short circuits and earth faults.

What is the rated current?

The circuit breaker has a rated current of 1600 A.

Which trip unit is installed?

The breaker is equipped with the ABB PR332/P-LSIG electronic trip unit.

How many poles does this breaker have?

This model is supplied as a four-pole fixed MCCB.

Where is this breaker typically installed?

It is commonly installed within industrial switchboards, power distribution panels, generator systems and transformer protection applications.