1SDA062988R1 ABB T7V 1250 PR331/P-LSIG 1250 A 4-Pole MCCB

1SDA062988R1 ABB T7V 1250 PR331/P-LSIG 1250 A 4-Pole MCCB

ABB 1SDA062988R1 T7V 1250 is a 1250 A four-pole fixed moulded case circuit breaker with a PR331/P-LSIG electronic trip unit and 150 kA breaking capacity at 380–415 V AC for comprehensive high-current low-voltage power distribution protection.

SKU: 1SDA062988R1MPN: 1SDA062988R1
Price
List Price £16,906.44 ex VAT
Your Price (ex VAT) Save 25%
£12,679.83 25% OFF
You save £4,226.61 per unit
Manufacturer Lead Time Estimated Delivery 10 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £12,679.83
Trade pricing is personalised to your account

Manufacturer Lead Time

£12,679.83

Why Choose the ABB 1SDA062988R1 T7V 1250 Circuit Breaker?

The ABB 1SDA062988R1, extended product type T7V 1250 PR331/P LSIG In=1250A 4p F F M, is a high-performance moulded case circuit breaker (MCCB) designed for protection and switching in demanding low-voltage electrical distribution systems. Part of the ABB SACE Tmax T7 series, it combines a 1250 A rated uninterrupted current, four-pole construction and a PR331/P-LSIG electronic trip unit.

The PR331/P-LSIG release provides long-time overload, short-time delayed short-circuit, instantaneous short-circuit and ground-fault protection. Its adjustable protection functions allow the breaker characteristics to be coordinated with the electrical installation, making the device particularly suitable for high-current incomers and feeders where comprehensive electronic protection is required.

With a rated ultimate short-circuit breaking capacity of 150 kA at 380–415 V AC, the T7V 1250 is engineered for installations with very high prospective fault currents. This version is a fixed four-pole breaker with front terminals and a motorisable operating mechanism, providing a robust solution for industrial switchboards, infrastructure and high-capacity power distribution assemblies.

Key Advantages

  • High-performance ABB SACE Tmax T7V moulded case circuit breaker for demanding low-voltage distribution systems.
  • 1250 A rated uninterrupted current for high-current applications.
  • Four-pole construction for three-phase four-wire electrical distribution systems.
  • 150 kA ultimate breaking capacity at 380–415 V AC for installations with very high prospective fault currents.
  • Advanced PR331/P-LSIG electronic trip unit for comprehensive circuit protection.
  • Provides long-time, short-time, instantaneous and ground-fault protection.
  • Long-time overload protection adjustable from 0.4–1 × In.
  • Instantaneous short-circuit protection adjustable from 1.5–15 × In.
  • Ground-fault protection adjustable from 0.2–1 × In.
  • Fixed configuration with front terminals for integration into low-voltage switchboards and distribution assemblies.

Key Features

  • ABB SACE Tmax T7V 1250 series MCCB.
  • 1250 A rated uninterrupted current.
  • Four-pole construction.
  • PR331/P-LSIG electronic release.
  • Long-time overload protection.
  • Short-time delayed short-circuit protection.
  • Instantaneous short-circuit protection.
  • Ground-fault protection.
  • Long-time protection adjustable from 500–1250 A.
  • Instantaneous protection adjustable from 1875–18750 A.
  • Ground-fault protection adjustable from 250–1250 A.
  • Neutral protection settings of OFF, 50%, 100% or 200%.
  • 150 kA Icu at 380–415 V AC.
  • Breaking capacity of up to 200 kA at 220–230 V AC.
  • Fixed installation format with front terminals.
  • Motorisable configuration for integration into remotely operated distribution systems.

Comprehensive LSIG Protection for High-Current Power Distribution

Moulded case circuit breakers such as the ABB Tmax T7V protect low-voltage electrical distribution systems against damaging overcurrent and fault conditions. The PR331/P-LSIG trip unit extends this protection to include overload, short-time and instantaneous short-circuit protection together with ground-fault protection, helping protect cables, switchgear and connected equipment throughout the distribution network.

The combination of adjustable LSIG protection and the 150 kA breaking capacity at 380–415 V AC makes the 1SDA062988R1 particularly suitable for high-current networks where protection coordination and substantial fault interruption capability are required. Its four-pole construction also supports three-phase four-wire systems where neutral switching and configurable neutral protection are needed.

Typical Applications

  • Main and sub-main low-voltage distribution boards.
  • Three-phase four-wire electrical distribution systems.
  • Industrial switchboards and power distribution assemblies.
  • Main incomers and high-current feeder circuits.
  • Manufacturing and process plants.
  • Commercial and infrastructure power distribution.
  • Transformer secondary and feeder protection.
  • Electrical networks requiring ground-fault protection.
  • Installations with very high prospective short-circuit currents.

Technical Specifications

Series SACE Tmax T7
ABB product group 310511-T-Max T4 - T8
Order code 1SDA062988R1
EAN 8015644655372
Product type Moulded case circuit breaker (MCCB)
Breaker type T7V 1250
Rated uninterrupted current (Iu) 1250 A
Number of poles 4
Trip unit PR331/P-LSIG electronic release
Protection functions Long-time, short-time delayed, instantaneous and ground-fault protection
Long-time overload adjustment 500–1250 A
Instantaneous short-circuit adjustment 1875–18750 A
Ground-fault adjustment 250–1250 A
Neutral protection OFF / 50% / 100% / 200%
Ultimate breaking capacity (Icu) at 220–230 V AC 200 kA
Ultimate breaking capacity (Icu) at 380–415 V AC 150 kA
Ultimate breaking capacity (Icu) at 440 V AC 130 kA
Ultimate breaking capacity (Icu) at 500 V AC 100 kA
Ultimate breaking capacity (Icu) at 690 V AC 60 kA
Installation version Fixed
Terminal position Front
Operating configuration Motorisable
Dimensions (H × W × D) 268 × 235 × 178 mm
Country of origin Italy

Frequently Asked Questions

What is the ABB 1SDA062988R1 used for?

The ABB 1SDA062988R1 is a 1250 A four-pole moulded case circuit breaker designed for switching and protection of high-current low-voltage electrical distribution circuits against overload, short-circuit and ground-fault conditions.

What is the current rating of the ABB T7V 1250 1SDA062988R1?

The circuit breaker has a rated uninterrupted current of 1250 A, with long-time overload protection adjustable from 500–1250 A.

What breaking capacity does the ABB T7V 1250 1SDA062988R1 provide?

The breaker provides a rated ultimate short-circuit breaking capacity of 150 kA at 380–415 V AC, with breaking capacity reaching 200 kA at 220–230 V AC.

What trip unit is fitted to the ABB 1SDA062988R1?

The breaker is fitted with an ABB PR331/P-LSIG electronic trip unit, providing long-time overload, short-time delayed short-circuit, instantaneous short-circuit and ground-fault protection.

Is the ABB 1SDA062988R1 a four-pole circuit breaker?

Yes. The 1SDA062988R1 is a four-pole fixed circuit breaker with front terminals, making it suitable for three-phase four-wire distribution systems and applications requiring configurable neutral protection.

Trusted by Electrical Professionals Worldwide

ABB SACE Tmax moulded case circuit breakers are widely used in industrial, commercial and infrastructure power distribution systems where dependable electronic protection, high breaking capacity and configurable protection characteristics are required.