1SDA062982R1 ABB T7V 1250 PR332/P LSI 1250A 3P Circuit Breaker

1SDA062982R1 ABB T7V 1250 PR332/P LSI 1250A 3P Circuit Breaker

ABB 1SDA062982R1 is a SACE Tmax T7V 1250 A three-pole fixed moulded-case circuit breaker with a PR332/P LSI electronic trip unit, stored-energy operating mechanism and 150 kA ultimate short-circuit breaking capacity at 380–415 V AC for high-performance overload and short-circuit protection.

SKU: 1SDA062982R1MPN: 1SDA062982R1
Price
List Price £13,430.16 ex VAT
Your Price (ex VAT) Save 25%
£10,072.62 25% OFF
You save £3,357.54 per unit
Manufacturer Lead Time Estimated Delivery 10 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £10,072.62
Trade pricing is personalised to your account

Manufacturer Lead Time

£10,072.62

Why Choose the ABB T7V 1250 PR332/P LSI 1250A Circuit Breaker?

The ABB 1SDA062982R1, designated T7V 1250 PR332/P LSI In=1250A 3p F F M, is a high-performance three-pole moulded-case circuit breaker (MCCB) designed for protection and switching in demanding low-voltage power distribution systems. Part of the established ABB SACE Tmax T7 series, it combines a rated uninterrupted current of 1250 A with the PR332/P LSI electronic trip unit for configurable overload and short-circuit protection.

The T7V performance level provides very high short-circuit interruption capability, with an ultimate short-circuit breaking capacity of 150 kA at 380–415 V AC. The PR332/P LSI electronic release provides long-time, short-time and instantaneous protection functions, enabling effective protection of high-current circuits against sustained overloads and severe short-circuit conditions.

With its three-pole configuration, fixed construction, front terminals and stored-energy operating mechanism, the 1SDA062982R1 is designed for integration into professional low-voltage switchboards and power distribution assemblies. Its combination of 1250 A current capability, advanced electronic protection and high breaking capacity makes it particularly suitable for industrial, commercial and infrastructure installations with substantial prospective fault currents.

Key Advantages

  • High-performance 1250 A moulded-case circuit breaker for demanding low-voltage distribution systems.
  • 150 kA ultimate short-circuit breaking capacity at 380–415 V AC.
  • Advanced PR332/P LSI electronic trip unit for configurable circuit protection.
  • Provides long-time, short-time and instantaneous protection for effective overload and short-circuit protection.
  • Three-pole configuration designed for high-current three-phase electrical distribution networks.
  • Stored-energy operating mechanism supports professional switchboard and remote-operation applications.

Key Features

  • ABB SACE Tmax T7V 1250 series.
  • 1250 A rated uninterrupted current.
  • PR332/P LSI electronic protection trip unit.
  • LSI protection: long-time, short-time and instantaneous.
  • 150 kA Icu at 380–415 V AC.
  • Three-pole configuration.
  • 500–1250 A adjustable long-time overload setting range.
  • High-performance V-level short-circuit interruption capability.
  • Fixed construction with front main-circuit terminals.
  • Stored-energy operating mechanism.
  • Rated operational voltage up to 690 V AC.
  • Designed to IEC requirements for low-voltage circuit breakers.

Advanced LSI Protection for High-Power Distribution

The ABB Tmax T7V platform is engineered for high-current low-voltage systems where substantial fault interruption capability and configurable electronic protection are required. With a rated uninterrupted current of 1250 A and an ultimate short-circuit breaking capacity of 150 kA at 380–415 V AC, the 1SDA062982R1 provides robust protection for distribution networks with very high prospective short-circuit currents.

The PR332/P LSI electronic trip unit combines long-time overload, short-time and instantaneous protection functions, allowing protection characteristics to be coordinated with the requirements of the protected circuit and wider electrical installation. Together with its fixed three-pole construction and stored-energy operating mechanism, this makes the breaker a strong choice for high-current three-phase power distribution and critical feeder applications.

Typical Applications

  • Main low-voltage distribution switchboards.
  • Industrial power distribution systems.
  • Manufacturing and process plants.
  • Commercial buildings and infrastructure installations.
  • Transformer secondary and high-current feeder protection.
  • Three-phase electrical distribution networks.
  • High fault-level power distribution systems.

Technical Specifications

Series SACE Tmax T7
ABB order code 1SDA062982R1
ABB product group 310511-T-Max T4 - T8
EAN / GTIN 8015644655310
Product type Moulded-case circuit breaker (MCCB)
Frame T7V 1250
Short-circuit performance level V
Rated uninterrupted current Iu 1250 A
Number of poles 3
Trip unit PR332/P LSI
Release type Electronic
Protection functions LSI – long-time, short-time and instantaneous
Long-time overload setting range 500–1250 A
Rated operational voltage 690 V AC
Rated insulation voltage Ui 1000 V
Rated impulse withstand voltage Uimp 8 kV
Ultimate short-circuit breaking capacity Icu at 220–230 V AC 200 kA
Ultimate short-circuit breaking capacity Icu at 380–415 V AC 150 kA
Ultimate short-circuit breaking capacity Icu at 440 V AC 130 kA
Ultimate short-circuit breaking capacity Icu at 500 V AC 100 kA
Ultimate short-circuit breaking capacity Icu at 690 V AC 60 kA
Service short-circuit breaking capacity Ics at 220–230 V AC 200 kA
Service short-circuit breaking capacity Ics at 380–415 V AC 150 kA
Service short-circuit breaking capacity Ics at 440 V AC 130 kA
Service short-circuit breaking capacity Ics at 500 V AC 100 kA
Service short-circuit breaking capacity Ics at 690 V AC 45 kA
Rated short-time withstand current Icw 15 kA for 1 s
Installation Fixed
Terminal position Front
Operating mechanism Stored-energy mechanism
Electrical durability 3000 cycles
Mechanical durability 10000 cycles

Frequently Asked Questions

What is the ABB 1SDA062982R1 used for?

The ABB 1SDA062982R1 is a 1250 A three-pole moulded-case circuit breaker designed for switching and protection against overload and short-circuit conditions in high-current three-phase low-voltage electrical distribution systems.

What trip unit is fitted to the ABB T7V 1250 1SDA062982R1?

The circuit breaker is fitted with an ABB PR332/P LSI electronic trip unit, providing long-time overload, short-time and instantaneous short-circuit protection functions.

What is the breaking capacity of the ABB 1SDA062982R1?

The ABB T7V 1250 1SDA062982R1 has an ultimate short-circuit breaking capacity of 150 kA at 380–415 V AC, making it suitable for electrical installations with very high prospective fault currents.

What does LSI mean on the PR332/P trip unit?

LSI denotes long-time, short-time and instantaneous protection. These functions provide protection against sustained overloads, delayed short-circuit faults and severe short-circuit currents respectively.

Where is the ABB 1SDA062982R1 typically installed?

The breaker is typically installed in main low-voltage switchboards, industrial distribution panels, transformer secondary circuits and infrastructure power systems requiring 1250 A three-pole protection and very high short-circuit interruption performance.

Trusted Protection from ABB

ABB Tmax moulded-case circuit breakers are widely used in industrial, commercial and infrastructure power distribution systems, providing dependable circuit protection, flexible electronic trip functionality and high short-circuit interruption performance.