1SDA062972R1 ABB T7V 1250 PR331/P LSIG 1250 A 4-Pole Moulded Case Circuit Breaker

1SDA062972R1 ABB T7V 1250 PR331/P LSIG 1250 A 4-Pole Moulded Case Circuit Breaker

ABB T7V 1250 PR331/P LSIG 4-pole moulded case circuit breaker with a 1250 A rated current, fixed front-terminal configuration, comprehensive LSIG electronic protection and 150 kA breaking capacity at 400 V AC.

SKU: 1SDA062972R1MPN: 1SDA062972R1
Price
List Price £15,369.45 ex VAT
Your Price (ex VAT) Save 25%
£11,527.09 25% OFF
You save £3,842.36 per unit
Manufacturer Lead Time Estimated Delivery 10 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £11,527.09
Trade pricing is personalised to your account

Manufacturer Lead Time

£11,527.09

Why Choose the ABB T7V 1250 PR331/P LSIG Moulded Case Circuit Breaker?

The ABB T7V 1250 PR331/P LSIG is a high-performance 4-pole moulded case circuit breaker (MCCB) designed for protection and control of demanding low-voltage power distribution systems. Part of the proven ABB Tmax T7 series, it combines a 1250 A rated uninterrupted current with comprehensive electronic protection and very high short-circuit breaking capability.

Equipped with the PR331/P LSIG solid-state electronic release, the T7V 1250 provides long-time, short-time, instantaneous and earth-fault protection functions. Its adjustable protection settings support effective coordination with cables, switchgear and downstream electrical equipment in high-current industrial and commercial distribution networks.

With an ultimate short-circuit breaking capacity of 150 kA at 400 V AC, 50 Hz, a rated voltage of 690 V AC and a fixed four-pole configuration with front terminals, the T7V 1250 is engineered for high-capacity switchboards where dependable interruption of substantial prospective fault currents is essential.

Key Advantages

  • High-performance ABB Tmax T7 moulded case circuit breaker.
  • 1250 A rated uninterrupted current for high-capacity distribution circuits.
  • 150 kA Icu at 400 V AC, 50 Hz for demanding fault conditions.
  • PR331/P LSIG electronic trip unit for comprehensive circuit protection.
  • Long-time, short-time, instantaneous and earth-fault protection.
  • 500–1250 A adjustable overload release range.
  • 4-pole construction suitable for three-phase distribution systems incorporating a neutral conductor.
  • Fixed mounting with front terminals for integration into low-voltage switchboards.

Key Features

  • ABB Tmax T7 series.
  • T7V 1250 performance level.
  • 1250 A rated uninterrupted current.
  • 4-pole construction.
  • PR331/P LSIG solid-state electronic release.
  • Long-time overload protection.
  • Short-time delayed short-circuit protection.
  • Instantaneous short-circuit protection.
  • Integrated earth-fault protection.
  • 500–1250 A overload release adjustment range.
  • 750–12500 A short-time delayed short-circuit adjustment range.
  • 1875–15000 A instantaneous short-circuit adjustment range.
  • 150 kA ultimate short-circuit breaking capacity at 400 V AC, 50 Hz.
  • 690 V AC rated voltage.
  • Fixed mounting with front terminals.

Reliable Circuit Protection for Power Distribution

Moulded case circuit breakers such as the ABB Tmax T7 protect low-voltage electrical distribution circuits against overload, short-circuit and earth-fault conditions. The electronic protection unit monitors circuit current and initiates interruption when configured protection thresholds are exceeded, helping protect conductors, switchgear and connected electrical equipment.

The T7V 1250 combines a high 1250 A current rating with 150 kA breaking capability at 400 V AC and comprehensive PR331/P LSIG electronic protection. Its four-pole construction and fixed front-terminal configuration make it particularly suitable for high-capacity three-phase distribution systems requiring coordinated overload, short-circuit and earth-fault protection.

Typical Applications

  • Industrial low-voltage distribution switchboards.
  • Main incomer and feeder circuit protection.
  • High-current four-pole three-phase distribution systems.
  • Commercial and infrastructure electrical distribution.
  • Manufacturing and process-industry electrical systems.
  • Power distribution centres and switchgear assemblies.
  • High-fault-level installations requiring earth-fault protection.

Technical Specifications

Series Tmax T7
ABB order code 1SDA062972R1
EAN 8015644655211
Product type Moulded case circuit breaker
Rated uninterrupted current (Iu) 1250 A
Rated voltage 690 V AC
Number of poles 4
Trip unit PR331/P
Protection functions LSIG
Ultimate short-circuit breaking capacity (Icu) 150 kA at 400 V AC, 50 Hz
Overload release adjustment range 500–1250 A
Short-time delayed short-circuit adjustment range 750–12500 A
Instantaneous short-circuit adjustment range 1875–15000 A
Earth-fault protection Integrated
Mounting type Fixed
Terminal configuration Front terminals
Motor drive integrated No
ABB product group 310511-T-Max T4 - T8

Frequently Asked Questions

What is the ABB T7V 1250 PR331/P LSIG used for?

This moulded case circuit breaker is designed to protect high-current low-voltage distribution circuits against overload, short-circuit and earth-fault conditions in demanding industrial and commercial electrical systems.

What is the rated current of ABB order code 1SDA062972R1?

The ABB T7V 1250 1SDA062972R1 has a rated uninterrupted current of 1250 A, with an adjustable overload release range of 500–1250 A.

What is the breaking capacity of the ABB T7V 1250 1SDA062972R1?

The breaker has an ultimate short-circuit breaking capacity of 150 kA at 400 V AC, 50 Hz.

Which trip unit is fitted to the ABB T7V 1250 1SDA062972R1?

This model is equipped with the ABB PR331/P LSIG solid-state electronic release, providing long-time, short-time, instantaneous and earth-fault protection functions.

Does the ABB T7V 1250 1SDA062972R1 provide earth-fault protection?

Yes. The PR331/P LSIG trip unit incorporates earth-fault protection in addition to long-time, short-time and instantaneous protection.

How is the ABB 1SDA062972R1 configured for installation?

ABB order code 1SDA062972R1 is a 4-pole fixed Tmax T7V circuit breaker with front terminals for integration into low-voltage switchboards and distribution assemblies.

Trusted by Electrical Professionals Worldwide

ABB Tmax moulded case circuit breakers are widely used by electrical engineers, panel builders and industrial operators for dependable circuit protection, power distribution and control in demanding low-voltage installations.