1SDA062962R1 ABB T7V 1250 PR231/P-LS/I 1250 A 3-Pole MCCB

1SDA062962R1 ABB T7V 1250 PR231/P-LS/I 1250 A 3-Pole MCCB

ABB 1SDA062962R1 T7V 1250 is a 1250 A three-pole fixed moulded case circuit breaker with a PR231/P-LS/I electronic trip unit and 150 kA breaking capacity at 380–415 V AC for high-current low-voltage power distribution.

SKU: 1SDA062962R1MPN: 1SDA062962R1
Price
List Price £11,334.66 ex VAT
Your Price (ex VAT) Save 25%
£8,501.00 25% OFF
You save £2,833.67 per unit
Manufacturer Lead Time Estimated Delivery 10 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £8,501.00
Trade pricing is personalised to your account

Manufacturer Lead Time

£8,501.00

Why Choose the ABB 1SDA062962R1 T7V 1250 Circuit Breaker?

The ABB 1SDA062962R1, extended product type T7V 1250 PR231/P LS/I In=1250A 3p F F, is a high-performance moulded case circuit breaker (MCCB) designed for protection and switching in high-current low-voltage electrical distribution systems. As part of the established ABB SACE Tmax T7 series, it combines a 1250 A rated uninterrupted current with a PR231/P-LS/I electronic trip unit for adjustable overload and short-circuit protection.

This T7V configuration is a fixed three-pole circuit breaker with front terminals and a lever operating mechanism, making it suitable for demanding industrial switchboards and power distribution assemblies. The PR231/P-LS/I electronic release provides long-time overload protection together with selectable short-time delayed or instantaneous short-circuit protection, allowing the protection characteristics to be coordinated with the requirements of the electrical installation.

With a rated uninterrupted current of 1250 A and a rated ultimate short-circuit breaking capacity of 150 kA at 380–415 V AC, the T7V 1250 is engineered for installations with very high prospective fault currents. Its robust Tmax construction, configurable electronic protection and fixed front-terminal arrangement make it well suited to industrial plants, infrastructure and large low-voltage power distribution systems.

Key Advantages

  • High-performance ABB SACE Tmax T7V moulded case circuit breaker for demanding power distribution applications.
  • 1250 A rated uninterrupted current for high-current electrical systems.
  • 150 kA ultimate breaking capacity at 380–415 V AC for networks with very high prospective fault currents.
  • PR231/P-LS/I electronic trip unit providing configurable overload and short-circuit protection.
  • Long-time protection adjustable from 0.4–1 × In.
  • Three-pole fixed configuration with front terminals for switchboard installation.
  • High T7V breaking performance supports demanding main incomer and feeder applications.

Key Features

  • ABB SACE Tmax T7V 1250 series MCCB.
  • 1250 A rated uninterrupted current.
  • PR231/P-LS/I electronic release.
  • Long-time overload protection with selectable short-time or instantaneous short-circuit protection.
  • 150 kA Icu at 380–415 V AC.
  • Three-pole construction.
  • Fixed circuit breaker installation format.
  • Front terminals for main power connections.
  • Long-time protection threshold adjustable from 0.4–1 × In.
  • Short-circuit protection threshold adjustable from 1–10 × In.
  • Rated insulation voltage of 1000 V and impulse withstand voltage of 8 kV.
  • Utilisation category B according to IEC 60947-2.

High-Performance Protection for Power Distribution

Moulded case circuit breakers such as the ABB Tmax T7V protect low-voltage electrical distribution systems against excessive currents caused by overload and short-circuit conditions. By rapidly interrupting dangerous fault currents, the breaker helps protect cables, switchgear and connected equipment while supporting the safety and continuity of the electrical installation.

The PR231/P-LS/I electronic trip unit provides adjustable long-time overload protection together with selectable short-time delayed or instantaneous short-circuit protection. Combined with the high breaking capacity of the T7V platform, the 1SDA062962R1 provides a robust solution for industrial power systems requiring configurable protection, selective coordination and dependable interruption of very high prospective fault currents.

Typical Applications

  • Main and sub-main low-voltage distribution boards.
  • Industrial switchboards and power distribution assemblies.
  • Main incomers and high-current feeder circuits.
  • Manufacturing and process plants.
  • Commercial and infrastructure power distribution.
  • Transformer secondary and feeder protection.
  • Electrical networks with very high prospective short-circuit currents.

Technical Specifications

Series SACE Tmax T7
ABB product group 310511-T-Max T4 - T8
Order code 1SDA062962R1
Product type Moulded case circuit breaker (MCCB)
Breaker type T7V 1250
Rated uninterrupted current (Iu) 1250 A
Number of poles 3
Trip unit PR231/P-LS/I electronic release
Protection functions Long-time overload with selectable short-time delayed or instantaneous short-circuit protection
Long-time protection adjustment 0.4–1 × In
Short-circuit protection adjustment 1–10 × In
Short-time delay 0.1 or 0.25 s at 10 × In
Rated operational voltage 690 V AC, 50 / 60 Hz
Rated insulation voltage 1000 V
Rated impulse withstand voltage 8 kV
Ultimate breaking capacity (Icu) at 220–230 V AC 200 kA
Ultimate breaking capacity (Icu) at 380–415 V AC 150 kA
Ultimate breaking capacity (Icu) at 440 V AC 130 kA
Ultimate breaking capacity (Icu) at 500 V AC 100 kA
Ultimate breaking capacity (Icu) at 690 V AC 60 kA
Service breaking capacity (Ics) at 380–415 V AC 150 kA
Service breaking capacity (Ics) at 690 V AC 45 kA
Rated short-time withstand current (Icw) 15 kA for 1 s
Utilisation category B
Installation version Fixed
Terminal type Front terminals
Operating mechanism Lever operated
Dimensions (H × W × D) 268 × 210 × 154 mm
Weight approx. 9.7 kg
Mechanical durability 10,000 operations
Electrical durability at 415 V AC 3,000 operations
Operating temperature -25 to +70 °C
Standard IEC 60947-2

Frequently Asked Questions

What is the ABB 1SDA062962R1 used for?

The ABB 1SDA062962R1 is a 1250 A moulded case circuit breaker used for switching and protection of high-current low-voltage electrical distribution circuits against overload and short-circuit conditions.

What is the current rating of the ABB T7V 1250 1SDA062962R1?

The circuit breaker has a rated uninterrupted current of 1250 A, with adjustable long-time protection from 0.4–1 × In.

What breaking capacity does the ABB T7V 1250 provide?

The T7V configuration provides a rated ultimate short-circuit breaking capacity of 150 kA at 380–415 V AC, making it suitable for electrical systems with very high prospective fault currents.

What trip unit is fitted to the 1SDA062962R1?

The breaker is fitted with an ABB PR231/P-LS/I electronic trip unit providing long-time overload protection together with selectable short-time delayed or instantaneous short-circuit protection.

How is the ABB 1SDA062962R1 installed?

This model is a fixed three-pole circuit breaker with front terminals and a lever operating mechanism, designed for installation in low-voltage switchboards and power distribution assemblies.

Trusted by Electrical Professionals Worldwide

ABB SACE Tmax moulded case circuit breakers are widely used in industrial, commercial and infrastructure power distribution systems where dependable circuit protection, high breaking capacity and configurable electronic protection are required.