ABB 1SDA062955R1 is a T7L1250 1250 A four-pole fixed moulded case circuit breaker with a PR232/P LSI electronic trip unit providing long-time overload, short-time and instantaneous short-circuit protection.

SKU: 1SDA062955R1MPN: 1SDA062955R1
Price
List Price £15,437.74 ex VAT
Your Price (ex VAT) Save 25%
£11,578.31 25% OFF
You save £3,859.44 per unit
Manufacturer Lead Time Estimated Delivery 10 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £11,578.31
Trade pricing is personalised to your account

Manufacturer Lead Time

£11,578.31

Why Choose the ABB T7L1250 PR232/P-LSI 1250A 4-Pole Circuit Breaker?

The ABB T7L1250 PR232/P-LSI is a high-performance moulded case circuit breaker (MCCB) designed for dependable protection and switching in high-current low-voltage power distribution systems. Part of the ABB SACE Tmax T7 series, this model combines a 1250 A rated current with the PR232/P electronic trip unit for comprehensive overcurrent protection.

The PR232/P-LSI electronic release provides long-time overload, short-time short-circuit and instantaneous short-circuit protection. These protection functions enable the breaker to respond effectively to different overcurrent conditions while supporting coordination and selectivity with other protective devices in industrial and commercial distribution networks.

This model is supplied in an authoritative 4-pole fixed configuration. The T7L frame is engineered for demanding high-current applications, while the four-pole arrangement makes the breaker suitable for three-phase distribution systems requiring four-pole switching and protection.

Key Advantages

  • High-performance ABB SACE Tmax T7 moulded case circuit breaker.
  • 1250 A rated current for high-current power distribution.
  • 4-pole configuration for three-phase distribution systems.
  • Electronic PR232/P-LSI trip unit.
  • Long-time protection against sustained overload conditions.
  • Short-time and instantaneous protection against short-circuit faults.
  • Electronic protection supports effective system coordination and selectivity.
  • T7L performance frame for demanding electrical installations.
  • Fixed configuration for integration into low-voltage switchboards.

Key Features

  • ABB SACE Tmax T7L series.
  • 1250 A rated current.
  • 4-pole construction.
  • PR232/P electronic trip unit.
  • LSI protection functions.
  • Long-time overload protection.
  • Short-time short-circuit protection.
  • Instantaneous short-circuit protection.
  • Electronic protection technology for dependable fault response.
  • Fixed mounting configuration.
  • Designed for high-current low-voltage power distribution.

Advanced Electronic Protection for Power Distribution

Moulded case circuit breakers such as the ABB Tmax T7 provide dependable switching, isolation and overcurrent protection for low-voltage electrical distribution systems. Electronic trip technology enables accurate detection of overload and short-circuit conditions while supporting protection coordination throughout the electrical network.

The PR232/P-LSI release combines long-time overload protection with short-time and instantaneous short-circuit protection. Together with the T7L frame and four-pole construction, this configuration provides a robust protection solution for high-current distribution systems requiring dependable electronic fault protection.

Typical Applications

  • Industrial low-voltage switchboards.
  • Main and sub-main power distribution systems.
  • High-current feeder protection.
  • Three-phase power distribution systems.
  • Manufacturing and process facilities.
  • Commercial and infrastructure electrical installations.

Technical Specifications

Series SACE Tmax T7
ABB order code 1SDA062955R1
ABB product group 310511-T-Max T4 - T8
Product type Moulded case circuit breaker
Frame T7L
Rated current 1250 A
Number of poles 4
Trip unit PR232/P
Release type Electronic
Protection functions LSI
Long-time protection (L) Overload protection
Short-time protection (S) Short-circuit protection
Instantaneous protection (I) Short-circuit protection
Mounting Fixed

Frequently Asked Questions

What is the ABB 1SDA062955R1 used for?

The ABB 1SDA062955R1 is a Tmax T7L moulded case circuit breaker designed for switching and protecting high-current low-voltage power distribution circuits.

What is the rated current of the ABB T7L1250 PR232/P-LSI?

The circuit breaker has a rated current of 1250 A.

What protection functions does the PR232/P-LSI trip unit provide?

The PR232/P-LSI electronic trip unit provides long-time overload, short-time short-circuit and instantaneous short-circuit protection.

How many poles does the ABB 1SDA062955R1 have?

The breaker has a 4-pole configuration, making it suitable for three-phase distribution systems requiring four-pole switching and protection.

How is the ABB 1SDA062955R1 installed?

The T7L1250 is supplied in a fixed configuration for integration into low-voltage switchboards and power-distribution systems.

Trusted by Electrical Professionals Worldwide

ABB SACE Tmax circuit breakers are widely used in industrial, commercial and infrastructure power systems where dependable electronic protection, flexible coordination and robust high-current distribution performance are required.