ABB 1SDA062938R1 is a SACE Tmax T7L 1250 A four-pole fixed moulded-case circuit breaker with a PR231/P LS/I electronic trip unit and 120 kA ultimate breaking capacity at 380–415 V AC for adjustable overload and short-circuit protection.
£9,862.70
The ABB 1SDA062938R1, designated T7L 1250 PR231/P LS/I In=1250A 4p F F, is a high-performance four-pole moulded-case circuit breaker (MCCB) designed for protection and switching in demanding low-voltage power distribution systems. Part of the established ABB SACE Tmax T7 series, it combines a rated uninterrupted current of 1250 A with the PR231/P LS/I electronic trip unit for adjustable overload and short-circuit protection.
The T7L version provides substantial short-circuit interruption capability, with a rated ultimate short-circuit breaking capacity of 120 kA at 380–415 V AC. Its PR231/P LS/I solid-state release provides adjustable long-time overload protection together with selectable short-time or instantaneous short-circuit protection, allowing the breaker to be configured for the protection requirements of high-current distribution circuits.
With its four-pole configuration, fixed installation, front terminals and manual lever operating mechanism, the 1SDA062938R1 is designed for reliable integration into low-voltage switchboards and distribution assemblies. Its 1250 A current rating, high breaking capacity and adjustable electronic protection make it suitable for industrial, commercial and infrastructure installations with significant prospective fault currents.
The ABB Tmax T7L platform is designed for high-current low-voltage systems where substantial short-circuit interruption capability is required. With a rated uninterrupted current of 1250 A and an ultimate breaking capacity of 120 kA at 380–415 V AC, the 1SDA062938R1 is well suited to distribution networks with high prospective fault levels.
The PR231/P LS/I electronic trip unit provides adjustable overload protection from 500–1250 A and adjustable short-circuit protection, with short-time delayed or instantaneous protection available as alternative functions. This flexibility supports effective protection coordination while the four-pole construction enables use in three-phase and neutral distribution systems.
| Series | SACE Tmax T7 |
|---|---|
| ABB order code | 1SDA062938R1 |
| ABB product group | 310511-T-Max T4 - T8 |
| EAN | 8015644654870 |
| Product type | Moulded-case circuit breaker (MCCB) |
| Frame | T7L 1250 |
| Rated uninterrupted current | 1250 A |
| Number of poles | 4 |
| Trip unit | PR231/P LS/I |
| Release type | Electronic |
| Long-time overload adjustment | 0.4–1 × In |
| Long-time overload adjustment range | 500–1250 A |
| Short-circuit protection adjustment | 1.5–12 × In |
| Short-circuit protection adjustment range | 1875–15000 A |
| Neutral protection settings | OFF / 50% / 100% |
| Rated operational voltage | 690 V AC |
| Rated insulation voltage | 1000 V |
| Rated impulse withstand voltage | 8 kV |
| Ultimate short-circuit breaking capacity Icu at 220–230 V AC | 200 kA |
| Ultimate short-circuit breaking capacity Icu at 380–415 V AC | 120 kA |
| Ultimate short-circuit breaking capacity Icu at 440 V AC | 100 kA |
| Ultimate short-circuit breaking capacity Icu at 500 V AC | 85 kA |
| Ultimate short-circuit breaking capacity Icu at 690 V AC | 50 kA |
| Rated service short-circuit breaking capacity Ics at 380–415 V AC | 120 kA |
| Rated short-time withstand current Icw | 20 kA for 1 s |
| Installation | Fixed |
| Terminal position | Front |
| Operating mechanism | Manual lever |
| Electrical durability | 2000 cycles |
| Mechanical durability | 10000 cycles |
| Power loss | 47 W per pole at rated operating conditions |
| Dimensions (H × W × D) | 268 × 280 × 154 mm |
| Net weight | 12.5 kg |
The ABB 1SDA062938R1 is a 1250 A four-pole moulded-case circuit breaker designed for switching and protection against overload and short-circuit conditions in high-current low-voltage electrical distribution systems.
The circuit breaker is fitted with an ABB PR231/P LS/I electronic trip unit, providing adjustable long-time overload protection and selectable short-time or instantaneous short-circuit protection.
The 1SDA062938R1 has a rated ultimate short-circuit breaking capacity of 120 kA at 380–415 V AC, increasing to 200 kA at 220–230 V AC.
The long-time overload protection is adjustable from 0.4–1 × In, corresponding to 500–1250 A, while short-circuit protection is adjustable from 1.5–12 × In.
The breaker is typically installed in main low-voltage switchboards, industrial distribution panels, transformer secondary circuits and infrastructure power systems requiring 1250 A four-pole protection and high short-circuit interruption performance.
ABB Tmax moulded-case circuit breakers are widely used in industrial, commercial and infrastructure power distribution systems, providing dependable circuit protection, flexible electronic trip functionality and high short-circuit interruption performance.