1SDA062938R1 ABB T7L 1250 PR231/P LS/I 1250A 4P Circuit Breaker

1SDA062938R1 ABB T7L 1250 PR231/P LS/I 1250A 4P Circuit Breaker

ABB 1SDA062938R1 is a SACE Tmax T7L 1250 A four-pole fixed moulded-case circuit breaker with a PR231/P LS/I electronic trip unit and 120 kA ultimate breaking capacity at 380–415 V AC for adjustable overload and short-circuit protection.

SKU: 1SDA062938R1MPN: 1SDA062938R1
Price
List Price £13,150.26 ex VAT
Your Price (ex VAT) Save 25%
£9,862.70 25% OFF
You save £3,287.57 per unit
Manufacturer Lead Time Estimated Delivery 10 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £9,862.70
Trade pricing is personalised to your account

Manufacturer Lead Time

£9,862.70

Why Choose the ABB T7L 1250 PR231/P LS/I 1250A Circuit Breaker?

The ABB 1SDA062938R1, designated T7L 1250 PR231/P LS/I In=1250A 4p F F, is a high-performance four-pole moulded-case circuit breaker (MCCB) designed for protection and switching in demanding low-voltage power distribution systems. Part of the established ABB SACE Tmax T7 series, it combines a rated uninterrupted current of 1250 A with the PR231/P LS/I electronic trip unit for adjustable overload and short-circuit protection.

The T7L version provides substantial short-circuit interruption capability, with a rated ultimate short-circuit breaking capacity of 120 kA at 380–415 V AC. Its PR231/P LS/I solid-state release provides adjustable long-time overload protection together with selectable short-time or instantaneous short-circuit protection, allowing the breaker to be configured for the protection requirements of high-current distribution circuits.

With its four-pole configuration, fixed installation, front terminals and manual lever operating mechanism, the 1SDA062938R1 is designed for reliable integration into low-voltage switchboards and distribution assemblies. Its 1250 A current rating, high breaking capacity and adjustable electronic protection make it suitable for industrial, commercial and infrastructure installations with significant prospective fault currents.

Key Advantages

  • High-performance 1250 A moulded-case circuit breaker for demanding low-voltage distribution systems.
  • 120 kA ultimate breaking capacity at 380–415 V AC for high fault-level installations.
  • PR231/P LS/I electronic trip unit for adjustable overload and short-circuit protection.
  • Selectable short-time delayed or instantaneous short-circuit protection for application flexibility.
  • Four-pole configuration suitable for three-phase and neutral distribution networks.
  • Fixed installation with front terminals and manual lever operation for straightforward switchboard integration.

Key Features

  • ABB SACE Tmax T7L 1250 series.
  • 1250 A rated uninterrupted current.
  • PR231/P LS/I solid-state electronic trip unit.
  • 120 kA Icu at 380–415 V AC.
  • Four-pole configuration.
  • 0.4–1 × In adjustable long-time overload protection.
  • 1.5–12 × In adjustable short-circuit protection.
  • Neutral protection settings of OFF, 50% and 100%.
  • Fixed installation with front main-circuit terminals.
  • Manual lever operating mechanism.
  • Rated operational voltage up to 690 V AC.

Advanced Overload and Short-Circuit Protection

The ABB Tmax T7L platform is designed for high-current low-voltage systems where substantial short-circuit interruption capability is required. With a rated uninterrupted current of 1250 A and an ultimate breaking capacity of 120 kA at 380–415 V AC, the 1SDA062938R1 is well suited to distribution networks with high prospective fault levels.

The PR231/P LS/I electronic trip unit provides adjustable overload protection from 500–1250 A and adjustable short-circuit protection, with short-time delayed or instantaneous protection available as alternative functions. This flexibility supports effective protection coordination while the four-pole construction enables use in three-phase and neutral distribution systems.

Typical Applications

  • Main low-voltage distribution switchboards.
  • Industrial power distribution systems.
  • Manufacturing and process plants.
  • Commercial buildings and infrastructure installations.
  • Transformer secondary and feeder protection.
  • Three-phase and neutral distribution networks.
  • High fault-level electrical distribution systems.

Technical Specifications

Series SACE Tmax T7
ABB order code 1SDA062938R1
ABB product group 310511-T-Max T4 - T8
EAN 8015644654870
Product type Moulded-case circuit breaker (MCCB)
Frame T7L 1250
Rated uninterrupted current 1250 A
Number of poles 4
Trip unit PR231/P LS/I
Release type Electronic
Long-time overload adjustment 0.4–1 × In
Long-time overload adjustment range 500–1250 A
Short-circuit protection adjustment 1.5–12 × In
Short-circuit protection adjustment range 1875–15000 A
Neutral protection settings OFF / 50% / 100%
Rated operational voltage 690 V AC
Rated insulation voltage 1000 V
Rated impulse withstand voltage 8 kV
Ultimate short-circuit breaking capacity Icu at 220–230 V AC 200 kA
Ultimate short-circuit breaking capacity Icu at 380–415 V AC 120 kA
Ultimate short-circuit breaking capacity Icu at 440 V AC 100 kA
Ultimate short-circuit breaking capacity Icu at 500 V AC 85 kA
Ultimate short-circuit breaking capacity Icu at 690 V AC 50 kA
Rated service short-circuit breaking capacity Ics at 380–415 V AC 120 kA
Rated short-time withstand current Icw 20 kA for 1 s
Installation Fixed
Terminal position Front
Operating mechanism Manual lever
Electrical durability 2000 cycles
Mechanical durability 10000 cycles
Power loss 47 W per pole at rated operating conditions
Dimensions (H × W × D) 268 × 280 × 154 mm
Net weight 12.5 kg

Frequently Asked Questions

What is the ABB 1SDA062938R1 used for?

The ABB 1SDA062938R1 is a 1250 A four-pole moulded-case circuit breaker designed for switching and protection against overload and short-circuit conditions in high-current low-voltage electrical distribution systems.

What trip unit is fitted to the ABB T7L 1250 1SDA062938R1?

The circuit breaker is fitted with an ABB PR231/P LS/I electronic trip unit, providing adjustable long-time overload protection and selectable short-time or instantaneous short-circuit protection.

What is the breaking capacity of the ABB T7L 1250 1SDA062938R1?

The 1SDA062938R1 has a rated ultimate short-circuit breaking capacity of 120 kA at 380–415 V AC, increasing to 200 kA at 220–230 V AC.

What is the protection adjustment range of the PR231/P LS/I trip unit?

The long-time overload protection is adjustable from 0.4–1 × In, corresponding to 500–1250 A, while short-circuit protection is adjustable from 1.5–12 × In.

Where is the ABB 1SDA062938R1 typically installed?

The breaker is typically installed in main low-voltage switchboards, industrial distribution panels, transformer secondary circuits and infrastructure power systems requiring 1250 A four-pole protection and high short-circuit interruption performance.

Trusted Protection from ABB

ABB Tmax moulded-case circuit breakers are widely used in industrial, commercial and infrastructure power distribution systems, providing dependable circuit protection, flexible electronic trip functionality and high short-circuit interruption performance.