ABB 1SDA062930R1 is a T7L1250 1250 A three-pole fixed moulded case circuit breaker with front terminals, a PR231/P LS/I electronic trip unit and 120 kA ultimate breaking capacity at 415 V AC.

SKU: 1SDA062930R1Alt SKU: T7L1250PR231/PLS/IMPN: 1SDA062930R1
Price
List Price £10,752.83 ex VAT
Your Price (ex VAT) Save 25%
£8,064.62 25% OFF
You save £2,688.21 per unit
Manufacturer Lead Time Estimated Delivery 10 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £8,064.62
Trade pricing is personalised to your account

Manufacturer Lead Time

£8,064.62

Why Choose the ABB T7L1250 PR231/P-LS/I 1250A 3-Pole Circuit Breaker?

The ABB T7L1250 PR231/P-LS/I is a high-performance moulded case circuit breaker (MCCB) engineered for dependable protection and switching in high-current low-voltage distribution systems. Part of the ABB SACE Tmax T7 series, this model has a 1250 A rated current and combines the T7L frame with the PR231/P electronic trip unit.

The PR231/P-LS/I electronic release provides long-time overload, short-time short-circuit and instantaneous short-circuit protection. This combination provides comprehensive overcurrent protection while supporting coordination and selectivity with other protective devices in industrial and commercial electrical networks.

This breaker is supplied in an authoritative 3-pole fixed configuration with front terminals and provides an ultimate short-circuit breaking capacity of 120 kA at 415 V AC. Its high interruption capability makes it particularly suitable for installations where substantial prospective short-circuit currents can occur.

Key Advantages

  • High-performance ABB SACE Tmax T7 moulded case circuit breaker.
  • 1250 A rated current for high-current distribution circuits.
  • 3-pole configuration for three-phase electrical systems.
  • PR231/P-LS/I electronic trip unit.
  • Long-time overload, short-time and instantaneous short-circuit protection.
  • 120 kA breaking capacity at 415 V AC for demanding fault levels.
  • Electronic protection supports effective system coordination.
  • Fixed construction with front terminals for switchboard installation.

Key Features

  • ABB SACE Tmax T7L series.
  • 1250 A rated current.
  • 3-pole construction.
  • PR231/P electronic trip unit.
  • LS/I protection functions.
  • Long-time overload protection.
  • Short-time short-circuit protection.
  • Instantaneous short-circuit protection.
  • 120 kA ultimate breaking capacity at 415 V AC.
  • Fixed mounting configuration.
  • Front-terminal connection arrangement.
  • Designed for high-current three-phase power distribution.

High-Performance Protection for Power Distribution

Moulded case circuit breakers such as the ABB Tmax T7 provide switching, isolation and protection against damaging overcurrent conditions in low-voltage electrical systems. High breaking capacity is particularly important in main distribution networks and industrial installations where prospective short-circuit currents can be substantial.

The PR231/P-LS/I release combines long-time overload protection with short-time and instantaneous short-circuit protection. Together with the T7L frame and its 120 kA breaking capacity at 415 V AC, this configuration provides a robust solution for high-current distribution systems requiring dependable fault interruption.

Typical Applications

  • Industrial low-voltage switchboards.
  • Main and sub-main power distribution systems.
  • High-current three-phase feeder protection.
  • Manufacturing and process facilities.
  • Commercial and infrastructure electrical installations.
  • Distribution systems with high prospective short-circuit currents.

Technical Specifications

Series SACE Tmax T7
ABB order code 1SDA062930R1
ABB product group 310511-T-Max T4 - T8
Product type Moulded case circuit breaker
Frame T7L
Rated current 1250 A
Number of poles 3
Trip unit PR231/P
Release type Electronic
Protection functions LS/I
Long-time protection (L) Overload protection
Short-time protection (S) Short-circuit protection
Instantaneous protection (I) Short-circuit protection
Ultimate breaking capacity 120 kA at 415 V AC
Mounting Fixed
Terminal arrangement Front terminals

Frequently Asked Questions

What is the ABB 1SDA062930R1 used for?

The ABB 1SDA062930R1 is a Tmax T7L moulded case circuit breaker designed for switching and protecting high-current three-phase low-voltage power distribution circuits.

What is the rated current of the ABB T7L1250 PR231/P-LS/I?

The circuit breaker has a rated current of 1250 A.

What protection functions does the PR231/P-LS/I trip unit provide?

The PR231/P-LS/I electronic trip unit provides long-time overload, short-time short-circuit and instantaneous short-circuit protection.

What is the breaking capacity of the ABB 1SDA062930R1?

The T7L1250 has an ultimate short-circuit breaking capacity of 120 kA at 415 V AC.

What mounting and terminal configuration does the ABB 1SDA062930R1 use?

This breaker is supplied in a 3-pole fixed configuration with front terminals for integration into low-voltage switchboards.

Trusted by Electrical Professionals Worldwide

ABB SACE Tmax circuit breakers are widely used in industrial, commercial and infrastructure power systems where dependable electronic protection and high short-circuit interruption performance are required.