1sda062911r1  t7h 1250 pr332/p lsig in=1250a 4 pole abb mccb

1sda062911r1 t7h 1250 pr332/p lsig in=1250a 4 pole abb mccb

ABB Tmax T7H 1250 four pole moulded case circuit breaker with PR332/P LSIG electronic release, 1250 A rating and 690 V AC operating voltage.

SKU: 1SDA062911R1Alt SKU: T7H 1250 PR332/P LSIG In=1250A 4p F FMPN: 1SDA062911R1
Price
List Price £12,436.75 ex VAT
Your Price (ex VAT) Save 25%
£9,327.56 25% OFF
You save £3,109.19 per unit
Manufacturer Lead Time Estimated Delivery 10 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £9,327.56
Trade pricing is personalised to your account

Manufacturer Lead Time

£9,327.56

Why Choose the ABB 1SDA062911R1 Tmax T7H Moulded Case Circuit Breaker?

The ABB 1SDA062911R1 is a premium Tmax T7H moulded case circuit breaker (MCCB) designed to deliver dependable protection for industrial power distribution systems, commercial installations and critical low voltage applications. As part of the proven ABB SACE Tmax T series, it combines high fault interruption capability with advanced electronic protection and outstanding operational reliability.

This breaker is supplied as a fixed four-pole MCCB with front terminals, a lever operating mechanism and an advanced PR332/P LSIG electronic trip unit. The LSIG protection functions provide adjustable long-time, short-time, instantaneous and ground fault protection, allowing excellent discrimination and enhanced protection for complex electrical installations.

With a rated current of 1250 A and a rated operational voltage of up to 690 V AC, the ABB 1SDA062911R1 is ideal for switchboards, transformer protection, generator applications, industrial feeders and major commercial power distribution systems where maximum reliability is essential.

Key Advantages

  • High-performance ABB Tmax T7H moulded case circuit breaker.
  • 1250 A rated current for demanding industrial applications.
  • Four-pole configuration providing complete neutral isolation.
  • PR332/P LSIG electronic trip unit with adjustable protection.
  • Ground fault protection improves installation safety.
  • Fixed version with front terminal connections.
  • Excellent breaking capacity for industrial low voltage systems.

Key Features

  • ABB SACE Tmax T series.
  • T7H 1250 frame.
  • 1250 A rated uninterrupted current.
  • Four-pole MCCB.
  • PR332/P LSIG electronic release.
  • 690 V AC rated operational voltage.
  • 1000 V insulation voltage.
  • 8 kV impulse withstand voltage.
  • Front terminal fixed installation.
  • Designed for transformer, generator and installation protection.

Reliable Protection for Industrial Power Distribution

The ABB Tmax T7H range provides advanced overload, short-circuit and ground fault protection for modern electrical installations. The PR332/P LSIG trip unit allows engineers to configure protection parameters for optimum selectivity while helping minimise unnecessary downtime.

Its robust construction, excellent fault interruption capability and four-pole design make the ABB 1SDA062911R1 an ideal solution for demanding industrial applications requiring dependable protection and complete circuit isolation.

Typical Applications

  • Main low voltage switchboards.
  • Industrial manufacturing facilities.
  • Generator protection.
  • Transformer protection.
  • Commercial power distribution.
  • Motor control centres.
  • Infrastructure and utility installations.

Technical Specifications

Tick the specs you need, then view products that match.

Current 1250 A
Phase Three Phase
Poles 4-pole
Device Type MCCB
Breaking Capacity 70 kA
Trip Unit Electronic
Manufacturer ABB
Series SACE Tmax T
Model T7H 1250 PR332/P LSIG In=1250A 4p F F
Product code 1SDA062911R1
EAN 8015644654603
Product type Moulded Case Circuit Breaker
Rated current 1250 A
Rated uninterrupted current 1250 A
Number of poles 4P
Release PR332/P LSIG
Release type Electronic
Rated operational voltage 690 V AC
Rated insulation voltage 1000 V
Rated impulse withstand voltage 8 kV
Rated ultimate breaking capacity (Icu) 70 kA at 415 V AC
Rated service breaking capacity (Ics) 70 kA at 415 V AC
Rated short-time withstand current (Icw) 20 kA for 1 second
Terminal connection Fixed front terminals
Operating mechanism Lever operated
Electrical durability 2000 cycles
Mechanical durability 10000 cycles
Power loss 47 W per pole
Standards IEC
Dimensions (H × W × D) 268 × 280 × 154 mm
Weight 12.5 kg

Frequently Asked Questions

What is the ABB 1SDA062911R1 used for?

It protects industrial and commercial electrical distribution systems against overloads, short circuits and ground faults.

What is the rated current of this circuit breaker?

The ABB 1SDA062911R1 has a rated current of 1250 A.

Which trip unit is fitted?

This model is equipped with the PR332/P LSIG electronic trip unit, providing adjustable long-time, short-time, instantaneous and ground fault protection.

How many poles does this breaker have?

The ABB 1SDA062911R1 is supplied as a four-pole MCCB for complete three-phase and neutral isolation.

Where is this MCCB commonly installed?

It is commonly used in industrial switchboards, commercial electrical distribution systems, transformer protection and generator installations.

Trusted by Electrical Engineers Worldwide

ABB Tmax circuit breakers are trusted worldwide by panel builders, OEMs and electrical engineers for delivering dependable protection, outstanding breaking performance and reliable operation in demanding industrial environments.