1sda062873r1  t7s 1250 pr231/p i in=1250a 4 pole abb mccb

1sda062873r1 t7s 1250 pr231/p i in=1250a 4 pole abb mccb

ABB 1SDA062873R1 Tmax T7S 1250A four-pole moulded case circuit breaker with PR231/P-I electronic release, fixed front terminals and lever operating mechanism for low-voltage power distribution systems.

SKU: 1SDA062873R1Alt SKU: T7S 1250 PR231/P I In=1250A 4p F FMPN: 1SDA062873R1
Price
List Price £8,648.18 ex VAT
Your Price (ex VAT) Save 25%
£6,486.14 25% OFF
You save £2,162.05 per unit
Manufacturer Lead Time Estimated Delivery 10 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £6,486.14
Trade pricing is personalised to your account

Manufacturer Lead Time

£6,486.14

Why Choose the ABB 1SDA062873R1 Tmax T7S Moulded Case Circuit Breaker?

The ABB 1SDA062873R1 is a high-performance Tmax T7S moulded case circuit breaker designed to provide dependable protection for demanding low-voltage power distribution systems. As part of the established ABB SACE Tmax T range, it is engineered for industrial and commercial installations requiring high current capacity, reliable switching and accurate electronic protection.

This model features a 1250 A rated current, four-pole configuration and a PR231/P-I electronic release, providing reliable instantaneous protection for high-current power distribution applications. Its fixed front-terminal design supports straightforward installation into switchboards and panel assemblies, while the lever operating mechanism provides robust manual switching operation.

With a rated operational voltage of 690 V AC, rated insulation voltage of 1000 V and short-circuit breaking capacity up to 85 kA at 220-230 V AC, the ABB 1SDA062873R1 is ideal for main distribution boards, industrial switchgear, motor control centres and demanding low-voltage electrical protection applications.

Key Advantages

  • High-performance ABB Tmax T7S moulded case circuit breaker.
  • 1250 A rated current for demanding power distribution systems.
  • Four-pole fixed MCCB with front terminal connections.
  • PR231/P-I electronic release for reliable instantaneous protection.
  • Lever operating mechanism for robust manual switching.
  • High short-circuit performance for industrial and commercial installations.

Key Features

  • ABB SACE Tmax T7S series.
  • 1250 A rated uninterrupted current.
  • Four-pole MCCB configuration.
  • PR231/P-I solid-state electronic release.
  • Fixed version with front terminal connections.
  • Lever operating mechanism.
  • Rated operational voltage up to 690 V AC.
  • Designed for switchboards, distribution panels and industrial power systems.

Reliable Circuit Protection for Industrial Power Distribution

Moulded case circuit breakers such as the ABB Tmax T7S are used to protect electrical installations against short circuits and fault conditions. By disconnecting affected circuits quickly and reliably, they help protect cables, switchgear, machinery and connected equipment from electrical damage.

The PR231/P-I electronic release provides dependable instantaneous protection for high-current low-voltage systems. This makes the ABB 1SDA062873R1 well suited to installations where reliable switching, strong fault protection and continuity of service are important.

Typical Applications

  • Main low-voltage distribution boards.
  • Industrial switchboards and panel boards.
  • Motor control centres and machinery panels.
  • Commercial building electrical distribution.
  • Transformer and generator protection systems.
  • Heavy-duty industrial power protection applications.

Technical Specifications

Tick the specs you need, then view products that match.

Current 1250 A
Phase Three Phase
Poles 4-pole
Device Type MCCB
Breaking Capacity 85 kA
Trip Unit Electronic
Manufacturer ABB
Series SACE Tmax T
Model T7S 1250 PR231/P I In=1250A 4p F F
Product ID 1SDA062873R1
EAN 8015644654221
Product type Moulded case circuit breaker
Breaker type Automatic circuit breaker
Rated current 1250 A
Rated uninterrupted current 1250 A
Number of poles 4P
Release PR231/P-I
Release type Electronic
Short-circuit performance level S
Rated operational voltage 690 V AC
Rated insulation voltage 1000 V
Rated impulse withstand voltage 8 kV
Rated ultimate short-circuit breaking capacity 85 kA at 220-230 V AC, 50 kA at 380-440 V AC, 40 kA at 500 V AC, 30 kA at 690 V AC
Rated service short-circuit breaking capacity 85 kA at 220-230 V AC, 50 kA at 380-440 V AC, 40 kA at 500 V AC, 30 kA at 690 V AC
Rated short-time withstand current 20 kA for 1 s
Mechanical durability 10000 cycles
Electrical durability 2000 cycles
Power loss 47 W per pole at rated operating conditions
Terminal connection Fixed circuit breaker, front terminals
Version Fixed
Operating mechanism Lever operating mechanism
Standards IEC 60947-2
Dimensions (H × W × D) 268 × 280 × 154 mm
Weight 12.5 kg

Frequently Asked Questions

What is the ABB 1SDA062873R1 used for?

The ABB 1SDA062873R1 is used to protect low-voltage electrical distribution systems against short circuits and fault conditions.

What current rating does this circuit breaker have?

This circuit breaker has a rated current of 1250 A.

How many poles does the ABB 1SDA062873R1 have?

The ABB 1SDA062873R1 is a four-pole moulded case circuit breaker.

What trip unit is fitted to this MCCB?

It is fitted with a PR231/P-I electronic release for reliable instantaneous protection.

Where is this breaker typically installed?

It is typically installed in switchboards, distribution panels, motor control centres and industrial low-voltage power distribution systems.

Trusted by Electrical Engineers Worldwide

ABB Tmax moulded case circuit breakers are widely used by electrical engineers, panel builders and industrial facilities to deliver reliable low-voltage circuit protection in demanding power distribution applications.