1sda062870r1  t7s 1250 pr332/p lsi in=1250a 3 pole abb mccb

1sda062870r1 t7s 1250 pr332/p lsi in=1250a 3 pole abb mccb

ABB 1SDA062870R1 Tmax T7S 1250A three-pole moulded case circuit breaker with PR332/P-LSI electronic release for industrial low-voltage power distribution.

SKU: 1SDA062870R1Alt SKU: T7S 1250 PR332/P LSI In=1250A 3p F FMPN: 1SDA062870R1
Price
List Price £8,041.49 ex VAT
Your Price (ex VAT) Save 25%
£6,031.12 25% OFF
You save £2,010.37 per unit
Manufacturer Lead Time Estimated Delivery 10 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £6,031.12
Trade pricing is personalised to your account

Manufacturer Lead Time

£6,031.12

Why Choose the ABB 1SDA062870R1 Tmax T7S Moulded Case Circuit Breaker?

The ABB 1SDA062870R1 is a high-performance Tmax T7S moulded case circuit breaker designed to deliver dependable protection for demanding low-voltage power distribution systems. As part of the trusted ABB SACE Tmax T range, it combines high interrupting performance with advanced electronic protection, making it ideal for industrial plants, commercial facilities and critical infrastructure installations.

This model features a 1250 A rated current, a three-pole configuration and an advanced PR332/P-LSI electronic release, providing adjustable long-time, short-time and instantaneous protection. Its fixed front-terminal arrangement and lever operating mechanism simplify installation while ensuring reliable switching performance.

With a rated operational voltage of 690 V AC, rated insulation voltage of 1000 V and a breaking capacity of up to 50 kA at 415 V AC, the ABB 1SDA062870R1 is ideally suited for switchboards, motor control centres, generators and industrial power distribution systems.

Key Advantages

  • High-performance ABB Tmax T7S moulded case circuit breaker.
  • 1250 A rated current for demanding power distribution systems.
  • Three-pole fixed MCCB with front terminal connections.
  • Advanced PR332/P-LSI electronic trip unit.
  • Long-time, short-time and instantaneous protection functions.
  • Excellent short-circuit breaking performance for industrial installations.

Key Features

  • ABB SACE Tmax T7S series.
  • 1250 A rated uninterrupted current.
  • Three-pole MCCB configuration.
  • PR332/P-LSI electronic release.
  • Fixed version with front terminal connections.
  • Lever operating mechanism.
  • Rated operational voltage up to 690 V AC.
  • Designed for industrial low-voltage power distribution.

Reliable Circuit Protection for Industrial Power Distribution

The ABB Tmax T7S range protects electrical installations against overloads and short circuits while maintaining excellent selectivity and operational reliability. The electronic protection system enables precise adjustment to suit demanding industrial applications.

The integrated PR332/P-LSI electronic release provides advanced protection with adjustable long-time, short-time and instantaneous functions, making the ABB 1SDA062870R1 an excellent choice for critical low-voltage distribution systems.

Typical Applications

  • Main low-voltage distribution boards.
  • Industrial switchboards.
  • Motor control centres.
  • Commercial electrical distribution.
  • Generator and transformer protection.
  • Manufacturing plants and infrastructure projects.

Technical Specifications

Tick the specs you need, then view products that match.

Current 1250 A
Phase Three Phase
Poles 3-pole
Device Type MCCB
Breaking Capacity 85 kA
Trip Unit Electronic
Manufacturer ABB
Series SACE Tmax T
Model T7S 1250 PR332/P LSI In=1250A 3p F F
Product ID 1SDA062870R1
EAN 8015644654191
Product type Moulded case circuit breaker
Breaker type Automatic circuit breaker
Rated current 1250 A
Rated uninterrupted current 1250 A
Number of poles 3P
Release PR332/P-LSI
Release type Electronic
Short-circuit performance level S
Rated operational voltage 690 V AC
Rated insulation voltage 1000 V
Rated impulse withstand voltage 8 kV
Rated ultimate short-circuit breaking capacity 85 kA at 220 to 230 V AC, 50 kA at 380 to 440 V AC, 40 kA at 500 V AC, 30 kA at 690 V AC
Rated service short-circuit breaking capacity 85 kA at 220 to 230 V AC, 50 kA at 380 to 440 V AC, 40 kA at 500 V AC, 30 kA at 690 V AC
Rated short-time withstand current 20 kA for 1 s
Mechanical durability 10000 cycles
Electrical durability 2000 cycles
Power loss 47 W per pole
Terminal connection Fixed front terminals
Version Fixed
Operating mechanism Lever operating mechanism
Standards IEC 60947-2
Dimensions (H × W × D) 268 × 210 × 154 mm
Weight 9.7 kg

Frequently Asked Questions

What is the ABB 1SDA062870R1 used for?

The ABB 1SDA062870R1 protects low-voltage electrical systems against overloads and short circuits.

What current rating does this circuit breaker have?

This circuit breaker has a rated current of 1250 A.

Which electronic trip unit is fitted?

It is fitted with the PR332/P-LSI electronic release, providing adjustable long-time, short-time and instantaneous protection.

How many poles does this MCCB have?

The ABB 1SDA062870R1 is supplied as a three-pole moulded case circuit breaker.

Where is this breaker commonly installed?

It is commonly installed in industrial switchboards, motor control centres and low-voltage power distribution systems.

Trusted by Electrical Engineers Worldwide