ABB 1SDA062864R1 is a SACE Tmax T7V 1000 A four-pole fixed moulded case circuit breaker with front terminals, a stored-energy operating mechanism, PR332/P LSIRc electronic protection and 150 kA ultimate short-circuit breaking capacity at 380–415 V AC.
£12,210.93
The ABB 1SDA062864R1 is a high-performance SACE Tmax T7V 1000 moulded case circuit breaker (MCCB) designed for demanding low-voltage power distribution systems. It combines a 1000 A rated current, four-pole construction and the advanced ABB PR332/P LSIRc electronic trip unit for adjustable overload, short-circuit and residual-current protection.
As part of the ABB SACE Tmax T7 series, the T7V 1000 is engineered for installations with very high prospective fault currents. Its V performance level provides an ultimate short-circuit breaking capacity of 150 kA at 380–415 V AC, with specified breaking performance across systems operating at voltages up to 690 V AC.
The 1SDA062864R1 is a four-pole fixed circuit breaker with front terminals and a stored-energy operating mechanism. Its PR332/P LSIRc solid-state release provides long-time overload, short-time delayed and instantaneous short-circuit protection together with residual-current protection, providing a comprehensive protection solution for high-current distribution installations.
The ABB SACE Tmax T7 platform is designed for high-current low-voltage installations where both substantial fault-interruption capability and configurable electronic protection are required. The T7V 1000 combines a 1000 A current rating with ABB's V performance level, delivering an ultimate breaking capacity of 150 kA at 380–415 V AC and up to 200 kA at 220–230 V AC.
The PR332/P LSIRc electronic trip unit combines long-time overload, short-time delayed and instantaneous short-circuit functions with residual-current protection. This enables the breaker to provide coordinated distribution protection while also detecting residual leakage currents, making it particularly useful where enhanced protection against current flowing outside the intended circuit path is required.
| Series | SACE Tmax T7 |
|---|---|
| ABB designation | T7V 1000 PR332/P LSIRc In=1000A 4p F F M |
| Order code | 1SDA062864R1 |
| EAN | 8015644654139 |
| Product type | Moulded case circuit breaker (MCCB) |
| Frame | T7 |
| Performance level | V |
| Rated current (In) | 1000 A |
| Rated uninterrupted current (Iu) | 1000 A |
| Number of poles | 4 |
| Trip unit | PR332/P LSIRc |
| Trip-unit technology | Solid-state electronic |
| Protection functions | Long-time, short-time, instantaneous and residual current |
| Overload release adjustment | 400–1000 A |
| Short-time delayed short-circuit adjustment | 600–10000 A |
| Instantaneous short-circuit adjustment | 1500–15000 A |
| Residual-current adjustment | 0.2–1 × In |
| Neutral protection settings | OFF / 50% / 100% / 150% / 200% |
| Rated operational voltage | 690 V AC |
| Rated ultimate short-circuit breaking capacity (Icu) at 220–230 V AC | 200 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 380–415 V AC | 150 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC | 130 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 500 V AC | 100 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 690 V AC | 60 kA |
| Installation | Fixed |
| Terminal connection | Front terminals |
| Main-circuit connection | Bolted connection |
| Operating mechanism | Stored-energy mechanism |
| Motor drive | Optional |
| Degree of protection | IP20 |
| Dimensions (H × W × D) | 268 × 235 × 178 mm |
| ABB product group | 310511-T-Max T4 - T8 |
The ABB 1SDA062864R1 is a SACE Tmax T7V 1000 four-pole fixed moulded case circuit breaker rated at 1000 A, with front terminals, a stored-energy operating mechanism and a PR332/P LSIRc electronic trip unit.
The T7V 1000 has a rated ultimate short-circuit breaking capacity of 150 kA at 380–415 V AC, with breaking capacity reaching 200 kA at 220–230 V AC.
The PR332/P LSIRc electronic trip unit provides long-time overload, short-time delayed short-circuit, instantaneous short-circuit and residual-current protection.
The overload release is adjustable from 400–1000 A, the short-time delayed short-circuit release from 600–10000 A, and the instantaneous short-circuit release from 1500–15000 A.
Yes. The Rc function of the PR332/P LSIRc trip unit provides residual-current protection in addition to overload and short-circuit protection, making the breaker suitable for installations requiring enhanced detection of leakage or residual current.
ABB SACE Tmax T7 moulded case circuit breakers combine high-current capability, advanced electronic protection and substantial short-circuit breaking performance for dependable protection and coordination in demanding industrial and commercial low-voltage distribution systems.