1SDA062859R1 ABB T7V 1000 PR232/P LSI 1000A 4P Circuit Breaker

1SDA062859R1 ABB T7V 1000 PR232/P LSI 1000A 4P Circuit Breaker

ABB 1SDA062859R1 is a Tmax T7V 1000 A four-pole fixed moulded-case circuit breaker with a PR232/P LSI electronic trip unit for adjustable overload and short-circuit protection in demanding low-voltage power distribution systems.

SKU: 1SDA062859R1MPN: 1SDA062859R1
Price
List Price £16,038.61 ex VAT
Your Price (ex VAT) Save 25%
£12,028.96 25% OFF
You save £4,009.65 per unit
Manufacturer Lead Time Estimated Delivery 10 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £12,028.96
Trade pricing is personalised to your account

Manufacturer Lead Time

£12,028.96

Why Choose the ABB T7V 1000 PR232/P LSI 1000A Circuit Breaker?

The ABB 1SDA062859R1, designated T7V 1000 PR232/P LSI In=1000A 4p F, is a high-performance four-pole moulded-case circuit breaker (MCCB) designed for protection and switching in demanding low-voltage power distribution systems. As part of the established ABB Tmax T7 series, it combines a rated current of 1000 A with a PR232/P LSI electronic trip unit for reliable and adjustable overcurrent protection.

The T7V version is engineered for installations requiring very high short-circuit interruption performance. Its PR232/P LSI electronic trip unit provides long-time, short-time and instantaneous protection functions, enabling the breaker to protect electrical circuits against overload and short-circuit conditions while supporting effective protection coordination within industrial distribution networks.

With a four-pole configuration, 1000 A rated current and fixed installation format, the 1SDA062859R1 is well suited to three-phase and neutral distribution systems. It is designed for use in main switchboards, industrial power distribution panels, commercial installations and infrastructure where dependable high-current circuit protection is required.

Key Advantages

  • High-performance 1000 A moulded-case circuit breaker for demanding low-voltage distribution systems.
  • T7V high-breaking-capacity construction for installations with substantial prospective fault currents.
  • PR232/P LSI electronic trip unit for adjustable overcurrent protection.
  • Provides long-time, short-time and instantaneous protection.
  • Four-pole configuration suitable for three-phase and neutral distribution networks.
  • Fixed construction for integration into industrial and commercial switchboards.

Key Features

  • ABB Tmax T7V 1000 series.
  • 1000 A rated current.
  • PR232/P LSI electronic protection trip unit.
  • Four-pole configuration.
  • Long-time overload protection.
  • Short-time short-circuit protection.
  • Instantaneous short-circuit protection.
  • Adjustable electronic protection settings for distribution coordination.
  • Fixed installation format.
  • Designed for high-current low-voltage power distribution systems.

Reliable Electronic Protection for High-Power Distribution

Moulded-case circuit breakers such as the ABB Tmax T7 protect low-voltage electrical networks against overloads and short circuits. The T7V 1000 combines a high 1000 A current rating with the fault interruption capability required for demanding industrial and commercial power distribution applications.

The PR232/P LSI electronic trip unit provides separate long-time, short-time and instantaneous protection functions. These electronic protection characteristics allow the breaker to respond appropriately to overload and short-circuit conditions while supporting coordinated protection with other devices throughout a low-voltage distribution network.

Typical Applications

  • Main low-voltage distribution switchboards.
  • Industrial power distribution systems.
  • Manufacturing and process plants.
  • Commercial buildings and infrastructure installations.
  • Transformer secondary and feeder protection.
  • Three-phase and neutral distribution networks.
  • High fault-level electrical distribution systems.

Technical Specifications

Series Tmax T7
ABB order code 1SDA062859R1
ABB product group 310511-T-Max T4 - T8
Product type Moulded-case circuit breaker (MCCB)
Frame T7V 1000
Rated current 1000 A
Number of poles 4
Trip unit PR232/P LSI
Protection functions LSI – long-time, short-time and instantaneous
Rated operational voltage up to 690 V AC
Rated insulation voltage 1000 V
Rated impulse withstand voltage 8 kV
Frequency 50 / 60 Hz
Installation Fixed

Frequently Asked Questions

What is the ABB 1SDA062859R1 used for?

The ABB 1SDA062859R1 is a 1000 A four-pole moulded-case circuit breaker designed to protect and switch high-current low-voltage electrical distribution systems against overload and short-circuit conditions.

What trip unit is fitted to the ABB T7V 1000 1SDA062859R1?

The circuit breaker is equipped with an ABB PR232/P LSI electronic trip unit providing long-time, short-time and instantaneous overcurrent protection.

What is the rated current of the ABB 1SDA062859R1?

The ABB T7V 1000 1SDA062859R1 has a rated current of 1000 A, making it suitable for high-current low-voltage power distribution circuits.

What does LSI protection mean?

LSI denotes long-time, short-time and instantaneous protection, providing electronic protection against sustained overloads and different levels of short-circuit current.

Where is this circuit breaker typically installed?

The breaker is typically installed in low-voltage switchboards, industrial distribution panels, power distribution centres and infrastructure systems requiring high-current protection and adjustable electronic trip functionality.

Trusted Protection from ABB

ABB Tmax moulded-case circuit breakers are widely used in industrial, commercial and infrastructure power distribution systems, providing dependable circuit protection, flexible electronic trip functionality and robust performance in demanding electrical installations.