ABB 1SDA062848R1 is a Tmax T7V 1000 A four-pole moulded-case circuit breaker with a PR332/P LSIRc electronic trip unit for high-current low-voltage overcurrent and residual-current protection.

SKU: 1SDA062848R1MPN: 1SDA062848R1
Price
List Price £14,801.24 ex VAT
Your Price (ex VAT) Save 25%
£11,100.93 25% OFF
You save £3,700.31 per unit
Manufacturer Lead Time Estimated Delivery 10 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £11,100.93
Trade pricing is personalised to your account

Manufacturer Lead Time

£11,100.93

Why Choose the ABB T7V 1000 PR332/P LSIRc 1000A Circuit Breaker?

The ABB 1SDA062848R1, designated T7V 1000 PR332/P LSIRc In=1000A 4p, is a high-performance four-pole moulded-case circuit breaker (MCCB) designed for protection and switching in demanding low-voltage electrical distribution systems. As part of the proven ABB Tmax T7 series, it combines a rated current of 1000 A with the advanced PR332/P LSIRc electronic trip unit for comprehensive overcurrent and residual-current protection.

The T7V version is designed for applications requiring very high short-circuit interruption performance. The PR332/P LSIRc electronic trip unit provides long-time, short-time and instantaneous overcurrent protection together with residual-current protection, allowing the breaker to protect high-current distribution circuits against a broad range of electrical fault conditions.

With its four-pole configuration and 1000 A rated current, the 1SDA062848R1 is well suited to three-phase and neutral distribution systems in industrial plants, commercial buildings, infrastructure and main low-voltage switchboards. The T7 platform combines robust construction with flexible electronic protection for reliable operation in demanding electrical installations.

Key Advantages

  • High-performance 1000 A moulded-case circuit breaker for demanding power distribution applications.
  • T7V high-breaking-capacity construction for installations with substantial prospective fault currents.
  • Advanced PR332/P LSIRc electronic trip unit with residual-current protection.
  • Provides long-time, short-time and instantaneous overcurrent protection.
  • Four-pole configuration suitable for three-phase and neutral distribution networks.
  • ABB Tmax T7 construction provides dependable switching and protection in industrial electrical systems.

Key Features

  • ABB Tmax T7V 1000 series.
  • 1000 A rated current.
  • PR332/P LSIRc electronic protection trip unit.
  • Four-pole configuration.
  • Long-time overload protection.
  • Short-time short-circuit protection.
  • Instantaneous short-circuit protection.
  • Integrated residual-current protection.
  • Electronic protection settings for coordinated power distribution.
  • Designed for high-current low-voltage electrical installations.

Advanced Residual-Current and Overcurrent Protection

Moulded-case circuit breakers such as the ABB Tmax T7 protect low-voltage electrical networks against overloads, short circuits and other potentially damaging fault conditions. The T7V 1000 provides a high continuous-current capability and is designed for installations where dependable interruption of substantial prospective fault currents is essential.

The PR332/P LSIRc electronic trip unit combines long-time overload, short-time short-circuit and instantaneous short-circuit protection with residual-current functionality. Together with the four-pole construction, these capabilities make the breaker suitable for comprehensive protection of sophisticated three-phase and neutral low-voltage distribution networks.

Typical Applications

  • Main low-voltage distribution switchboards.
  • Industrial power distribution systems.
  • Manufacturing and process plants.
  • Commercial buildings and infrastructure installations.
  • Transformer secondary and feeder protection.
  • Three-phase and neutral distribution networks.
  • High fault-level electrical distribution systems.

Technical Specifications

Series Tmax T7
ABB order code 1SDA062848R1
ABB product group 310511-T-Max T4 - T8
Product type Moulded-case circuit breaker (MCCB)
Frame T7V 1000
Rated current 1000 A
Number of poles 4
Trip unit PR332/P LSIRc
Protection functions Long-time, short-time, instantaneous and residual-current protection
Rated operational voltage up to 690 V AC
Rated insulation voltage 1000 V
Rated impulse withstand voltage 8 kV
Frequency 50 / 60 Hz

Frequently Asked Questions

What is the ABB 1SDA062848R1 used for?

The ABB 1SDA062848R1 is a 1000 A four-pole moulded-case circuit breaker designed to protect and switch high-current low-voltage electrical distribution systems against overloads, short circuits and residual-current faults.

What trip unit is fitted to the ABB T7V 1000 1SDA062848R1?

The circuit breaker is equipped with an ABB PR332/P LSIRc electronic trip unit, providing long-time, short-time and instantaneous overcurrent protection together with residual-current protection.

What is the rated current of the ABB 1SDA062848R1?

The ABB T7V 1000 1SDA062848R1 has a rated current of 1000 A, making it suitable for high-current low-voltage distribution circuits.

Why does the 1SDA062848R1 have four poles?

The four-pole configuration allows the breaker to be used in three-phase and neutral distribution systems where coordinated switching and protection across four conductors are required.

Where is this circuit breaker typically installed?

The breaker is typically used in low-voltage switchboards, industrial distribution panels, power distribution centres and infrastructure systems requiring high-current protection and advanced electronic trip functionality.

Trusted Protection from ABB

ABB Tmax moulded-case circuit breakers are widely used in industrial, commercial and infrastructure power distribution systems, providing dependable circuit protection, flexible electronic trip functionality and high short-circuit interruption performance.