Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB 1SDA062846R1 is a SACE Tmax T7V 1000 A four-pole fixed moulded case circuit breaker with front terminals, lever operation, a PR332/P LSI electronic trip unit and 150 kA ultimate short-circuit breaking capacity at 380–415 V AC.
£10,143.59
The ABB 1SDA062846R1 is a high-performance SACE Tmax T7V 1000 moulded case circuit breaker (MCCB) designed for protection and switching in demanding low-voltage power distribution systems. This configuration combines a 1000 A rated current, four-pole construction and the advanced ABB PR332/P LSI electronic trip unit for comprehensive overload and short-circuit protection.
As part of the ABB SACE Tmax T7 series, the T7V 1000 is engineered for installations with exceptionally high prospective fault currents. Its V performance level provides a rated ultimate short-circuit breaking capacity of 150 kA at 380–415 V AC, with breaking capacities specified across low-voltage systems up to 690 V AC.
The 1SDA062846R1 is supplied as a four-pole fixed circuit breaker with front terminals and a lever operating mechanism. Its PR332/P LSI solid-state release provides long-time overload, short-time delayed short-circuit and instantaneous short-circuit protection, with independently adjustable settings to support selective and coordinated protection of high-current distribution circuits.
The ABB SACE Tmax T7 platform is engineered for high-current low-voltage installations where dependable interruption of severe prospective fault currents and coordinated protection are essential. The T7V 1000 combines a 1000 A current rating with ABB's V performance level, delivering an ultimate breaking capacity of 150 kA at 380–415 V AC and up to 200 kA at 220–230 V AC.
The PR332/P LSI electronic trip unit combines adjustable long-time overload, short-time delayed and instantaneous short-circuit protection. Its overload setting spans 400–1000 A, the short-time delayed function is adjustable from 600–10000 A, and instantaneous protection can be set from 1500–15000 A, providing flexibility for selective protection coordination in complex distribution networks.
| Series | SACE Tmax T7 |
|---|---|
| ABB designation | T7V 1000 PR332/P LSI In=1000A 4p F F |
| Order code | 1SDA062846R1 |
| EAN | 8015644653958 |
| Product type | Moulded case circuit breaker (MCCB) |
| Frame | T7 |
| Performance level | V |
| Rated current (In) | 1000 A |
| Rated uninterrupted current (Iu) | 1000 A |
| Number of poles | 4 |
| Trip unit | PR332/P LSI |
| Trip-unit technology | Solid-state electronic |
| Protection functions | Long-time, short-time and instantaneous |
| Overload release adjustment | 400–1000 A |
| Short-time delayed short-circuit adjustment | 600–10000 A |
| Instantaneous short-circuit adjustment | 1500–15000 A |
| Rated operational voltage | 690 V AC |
| Rated insulation voltage (Ui) | 1000 V |
| Rated impulse withstand voltage (Uimp) | 8 kV |
| Rated ultimate short-circuit breaking capacity (Icu) at 220–230 V AC | 200 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 380–415 V AC | 150 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC | 130 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 500 V AC | 100 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 690 V AC | 60 kA |
| Rated service short-circuit breaking capacity (Ics) at 380–415 V AC | 150 kA |
| Rated service short-circuit breaking capacity (Ics) at 690 V AC | 45 kA |
| Rated short-time withstand current (Icw) | 15 kA for 1 s |
| Installation | Fixed |
| Terminal position | Front |
| Main-circuit connection | Bolted connection |
| Operating mechanism | Lever |
| Degree of protection | IP20 |
| Electrical durability | 3000 operating cycles |
| Mechanical durability | 10,000 operating cycles |
| Power loss | 50 W per pole at rated operating conditions |
| Dimensions (H × W × D) | 268 × 235 × 154 mm |
| Net weight | approx. 9.9 kg |
| ABB product group | 310511-T-Max T4 - T8 |
The ABB 1SDA062846R1 is a SACE Tmax T7V 1000 four-pole fixed moulded case circuit breaker rated at 1000 A, with front terminals, lever operation and a PR332/P LSI electronic trip unit.
The T7V 1000 has a rated ultimate short-circuit breaking capacity of 150 kA at 380–415 V AC, with an Icu of up to 200 kA at 220–230 V AC.
The PR332/P LSI electronic trip unit provides long-time overload, short-time delayed short-circuit and instantaneous short-circuit protection.
The overload release is adjustable from 400–1000 A, the short-time delayed short-circuit release from 600–10000 A, and the instantaneous short-circuit release from 1500–15000 A.
Yes. The 1SDA062846R1 is a four-pole fixed Tmax T7V circuit breaker with front terminals and a lever operating mechanism, suitable for three-phase distribution systems incorporating a neutral conductor.
ABB SACE Tmax T7 moulded case circuit breakers combine high-current capability, advanced electronic protection and substantial short-circuit breaking performance for dependable protection and coordination in demanding industrial and commercial low-voltage distribution systems.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.