1SDA062826R1 ABB T7L1000 PR231/P-LS/I 1000A 4-Pole Circuit Breaker

1SDA062826R1 ABB T7L1000 PR231/P-LS/I 1000A 4-Pole Circuit Breaker

ABB 1SDA062826R1 is a T7L1000 1000 A four-pole fixed moulded case circuit breaker with a PR231/P LS/I electronic trip unit for adjustable overload and short-circuit protection in low-voltage power distribution systems.

SKU: 1SDA062826R1MPN: 1SDA062826R1
Price
List Price £13,368.01 ex VAT
Your Price (ex VAT) Save 25%
£10,026.01 25% OFF
You save £3,342.00 per unit
Manufacturer Lead Time Estimated Delivery 10 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £10,026.01
Trade pricing is personalised to your account

Manufacturer Lead Time

£10,026.01

Why Choose the ABB T7L1000 PR231/P-LS/I 1000A 4-Pole Circuit Breaker?

The ABB T7L1000 PR231/P-LS/I is a high-performance moulded case circuit breaker (MCCB) designed for reliable protection and switching in high-current low-voltage power distribution systems. As part of the proven ABB SACE Tmax T7 series, it combines a 1000 A rated current with the PR231/P electronic trip unit for adjustable overload and short-circuit protection.

The PR231/P-LS/I electronic release provides long-time overload, short-time short-circuit and instantaneous short-circuit protection. These protection functions allow the breaker to respond effectively to different overcurrent conditions while supporting coordination and selectivity within industrial and commercial electrical distribution systems.

This model is supplied in an authoritative 4-pole fixed configuration. The T7L performance level is engineered for installations requiring substantial short-circuit interruption capability, while its 1000 A rating makes it suitable for main distribution, high-current feeders and other demanding low-voltage applications.

Key Advantages

  • High-performance ABB SACE Tmax T7 moulded case circuit breaker.
  • 1000 A rated current for high-current power distribution.
  • 4-pole configuration for three-phase and neutral circuits.
  • Electronic PR231/P-LS/I trip unit.
  • Long-time overload protection for sustained overcurrent conditions.
  • Short-time and instantaneous protection against short circuits.
  • Adjustable electronic protection supports system coordination and selectivity.
  • Fixed configuration for integration into low-voltage switchboards.

Key Features

  • ABB SACE Tmax T7L series.
  • 1000 A rated current.
  • 4-pole construction.
  • PR231/P electronic trip unit.
  • LS/I protection functions.
  • Long-time overload protection.
  • Short-time short-circuit protection.
  • Instantaneous short-circuit protection.
  • Electronic protection technology for accurate fault response.
  • Fixed mounting configuration.
  • Designed for demanding low-voltage power distribution systems.

Reliable Electronic Protection for Power Distribution

Moulded case circuit breakers such as the ABB Tmax T7 protect low-voltage electrical systems against damaging overcurrent and short-circuit conditions while providing dependable circuit switching and isolation. Electronic trip technology enables protection characteristics to be coordinated with the requirements of the electrical installation.

The PR231/P-LS/I release combines long-time overload protection with short-time and instantaneous short-circuit protection. This combination provides versatile overcurrent protection for high-current distribution circuits while helping coordinate breaker operation with other protective devices in the network.

Typical Applications

  • Industrial low-voltage switchboards.
  • Main and sub-main power distribution systems.
  • High-current feeder protection.
  • Manufacturing and process facilities.
  • Commercial and infrastructure electrical installations.
  • Three-phase distribution systems requiring four-pole switching and protection.

Technical Specifications

Series SACE Tmax T7
ABB order code 1SDA062826R1
ABB product group 310511-T-Max T4 - T8
Product type Moulded case circuit breaker
Frame T7L
Rated current 1000 A
Number of poles 4
Trip unit PR231/P
Release type Electronic
Protection functions LS/I
Long-time protection Overload protection
Short-time protection Short-circuit protection
Instantaneous protection Short-circuit protection
Mounting type Fixed

Frequently Asked Questions

What is the ABB 1SDA062826R1 used for?

This Tmax T7L moulded case circuit breaker is designed for switching and protecting high-current low-voltage power distribution circuits in industrial, commercial and infrastructure installations.

What is the rated current of the ABB T7L1000 PR231/P-LS/I?

The circuit breaker has a rated current of 1000 A.

What protection functions does the PR231/P-LS/I trip unit provide?

The PR231/P-LS/I electronic trip unit provides long-time overload, short-time short-circuit and instantaneous short-circuit protection.

How many poles does the ABB 1SDA062826R1 have?

The breaker has a 4-pole configuration, making it suitable for three-phase power-distribution systems requiring four-pole switching and protection.

How is the ABB 1SDA062826R1 installed?

The T7L1000 is supplied in a fixed configuration for integration into low-voltage switchboards and power-distribution systems.

Trusted by Electrical Professionals Worldwide

ABB SACE Tmax circuit breakers are widely used in industrial, commercial and infrastructure power systems where dependable electronic protection, flexible coordination and robust high-current distribution performance are required.