Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB 1SDA062816R1 is a Tmax T7L 1000 A four-pole fixed moulded-case circuit breaker with a PR332/P LSIRc electronic trip unit, residual-current protection and 120 kA ultimate breaking capacity at 380–415 V AC.
£10,974.67
The ABB 1SDA062816R1, designated T7L 1000 PR332/P LSIRc In=1000A 4p F F, is a high-performance four-pole moulded-case circuit breaker (MCCB) designed for protection and switching in demanding low-voltage electrical distribution systems. As part of the proven ABB Tmax T7 series, it combines a rated uninterrupted current of 1000 A with the advanced PR332/P LSIRc electronic trip unit for comprehensive overcurrent and residual-current protection.
The T7L version provides high short-circuit interruption performance, with a rated ultimate short-circuit breaking capacity of 120 kA at 380–415 V AC. Its PR332/P LSIRc solid-state trip unit provides adjustable long-time, short-time and instantaneous overcurrent protection together with residual-current protection, allowing the breaker to respond effectively to a wide range of electrical fault conditions.
With its four-pole configuration, fixed installation and front main-circuit terminals, the 1SDA062816R1 is suitable for three-phase and neutral distribution systems in industrial plants, commercial buildings, infrastructure and main low-voltage switchboards. Its 1000 A rating and high breaking capacity make it particularly well suited to installations with substantial load currents and prospective short-circuit levels.
Moulded-case circuit breakers such as the ABB Tmax T7 protect low-voltage electrical networks against potentially damaging overload and short-circuit conditions. The T7L 1000 combines a continuous current capability of 1000 A with high short-circuit interruption performance, making it suitable for main distribution circuits and installations supplied by high-capacity transformers or other sources with significant prospective fault currents.
The PR332/P LSIRc electronic trip unit adds residual-current protection to adjustable long-time, short-time and instantaneous overcurrent functions. This combination enables comprehensive protection of power distribution circuits while providing engineers with adjustable protection thresholds for coordination with upstream and downstream protective devices.
| Series | Tmax T7 |
|---|---|
| ABB order code | 1SDA062816R1 |
| ABB product group | 310511-T-Max T4 - T8 |
| Product type | Moulded-case circuit breaker (MCCB) |
| Frame | T7L 1000 |
| Rated uninterrupted current | 1000 A |
| Number of poles | 4 |
| Trip unit | PR332/P LSIRc |
| Protection functions | Long-time, short-time, instantaneous and residual-current protection |
| Overload release adjustment | 400–1000 A |
| Short-time delayed short-circuit adjustment | 600–10000 A |
| Instantaneous short-circuit adjustment | 1500–15000 A |
| Residual-current adjustment | 0.2–1 × In |
| Rated operational voltage | up to 690 V AC |
| Ultimate short-circuit breaking capacity Icu at 220–230 V AC | 200 kA |
| Ultimate short-circuit breaking capacity Icu at 380–415 V AC | 120 kA |
| Ultimate short-circuit breaking capacity Icu at 440 V AC | 100 kA |
| Ultimate short-circuit breaking capacity Icu at 500 V AC | 85 kA |
| Ultimate short-circuit breaking capacity Icu at 690 V AC | 50 kA |
| Protection rating | IP20 |
| Installation | Fixed |
| Terminal position | Front |
| Main circuit connection | Bolt connection |
| Operating mechanism | Lever / toggle |
| Dimensions (H × W × D) | approx. 268 × 235 × 154 mm |
| Weight | approx. 9.9 kg |
The ABB 1SDA062816R1 is a 1000 A four-pole moulded-case circuit breaker used to protect and switch high-current low-voltage electrical distribution systems against overloads, short circuits and residual-current faults.
The circuit breaker is equipped with an ABB PR332/P LSIRc electronic trip unit, providing adjustable long-time, short-time and instantaneous overcurrent protection together with residual-current protection.
The T7L 1000 has a rated ultimate short-circuit breaking capacity of 120 kA at 380–415 V AC, with breaking capacity reaching 200 kA at 220–230 V AC.
The PR332/P LSIRc trip unit provides an adjustable overload release range of 400–1000 A, a short-time delayed short-circuit range of 600–10000 A and an instantaneous short-circuit range of 1500–15000 A.
The breaker is typically installed in low-voltage switchboards, industrial distribution panels, power distribution centres and infrastructure systems requiring high-current protection, residual-current protection and high short-circuit breaking performance.
ABB Tmax moulded-case circuit breakers are widely used in industrial, commercial and infrastructure power distribution systems, providing dependable circuit protection, flexible electronic trip functionality and high short-circuit interruption performance.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.