1SDA062815R1 ABB T7L 1000 PR332/P LSIG 1000A 4P Circuit Breaker

1SDA062815R1 ABB T7L 1000 PR332/P LSIG 1000A 4P Circuit Breaker

ABB 1SDA062815R1 is a Tmax T7L 1000 A four-pole fixed moulded-case circuit breaker with a PR332/P LSIG electronic trip unit and 120 kA ultimate breaking capacity at 380–415 V AC for demanding low-voltage power distribution systems.

SKU: 1SDA062815R1MPN: 1SDA062815R1
Price
List Price £14,543.64 ex VAT
Your Price (ex VAT) Save 25%
£10,907.73 25% OFF
You save £3,635.91 per unit
Manufacturer Lead Time Estimated Delivery 10 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £10,907.73
Trade pricing is personalised to your account

Manufacturer Lead Time

£10,907.73

Why Choose the ABB T7L 1000 PR332/P LSIG 1000A Circuit Breaker?

The ABB 1SDA062815R1, designated T7L 1000 PR332/P LSIG In=1000A 4p F F, is a high-performance four-pole moulded-case circuit breaker (MCCB) designed for protection and switching in demanding low-voltage power distribution systems. As part of the proven ABB Tmax T7 series, it combines a rated current of 1000 A with the advanced PR332/P LSIG electronic trip unit for comprehensive protection of high-current electrical installations.

The T7L version delivers high short-circuit interruption performance, with a rated ultimate short-circuit breaking capacity of 120 kA at 380–415 V AC. Its PR332/P LSIG electronic trip unit provides long-time, short-time, instantaneous and earth-fault protection, allowing protection characteristics to be adjusted for effective coordination and selectivity within complex distribution networks.

With its four-pole configuration, fixed installation and front terminals, the 1SDA062815R1 is particularly suitable for three-phase systems where switching and protection of the neutral conductor are required. The breaker supports a rated operational voltage of up to 690 V AC and is designed for installation in industrial switchboards, power distribution centres and major commercial or infrastructure electrical systems.

Key Advantages

  • High-performance 1000 A moulded-case circuit breaker for demanding power distribution applications.
  • 120 kA ultimate breaking capacity at 380–415 V AC for installations with high prospective fault currents.
  • Advanced PR332/P LSIG electronic trip unit for comprehensive circuit protection.
  • Provides long-time, short-time, instantaneous and earth-fault protection.
  • Four-pole configuration enables protection and switching of the neutral conductor.
  • Fixed installation with front terminals simplifies integration into low-voltage switchboards.

Key Features

  • ABB Tmax T7L 1000 series.
  • 1000 A rated current.
  • PR332/P LSIG electronic protection trip unit.
  • 120 kA Icu at 380–415 V AC.
  • Four-pole configuration.
  • 400–1000 A adjustable long-time protection range.
  • Adjustable short-circuit protection up to 15 × In.
  • Adjustable neutral protection settings for four-pole distribution systems.
  • Integrated earth-fault protection functionality.
  • Fixed installation with front main-circuit terminals.
  • Designed for high-current low-voltage power distribution systems.

Advanced Four-Pole Protection for Power Distribution

Moulded-case circuit breakers such as the ABB Tmax T7 protect low-voltage electrical networks against overloads, short circuits and earth faults. The T7L 1000 combines a high 1000 A current rating with substantial short-circuit interruption capability, making it suitable for main distribution circuits and installations supplied by high-capacity transformers or other sources with significant prospective fault currents.

The PR332/P LSIG electronic trip unit provides adjustable protection characteristics for long-time overload, short-time short-circuit, instantaneous short-circuit and earth-fault conditions. Combined with the four-pole construction and configurable neutral protection, this enables effective protection coordination across sophisticated three-phase and neutral distribution systems.

Typical Applications

  • Main low-voltage distribution switchboards.
  • Industrial power distribution systems.
  • Manufacturing and process plants.
  • Commercial buildings and infrastructure installations.
  • Transformer secondary and feeder protection.
  • Three-phase and neutral distribution networks.
  • High fault-level electrical distribution systems.

Technical Specifications

Series Tmax T7
ABB order code 1SDA062815R1
ABB product group 310511-T-Max T4 - T8
Product type Moulded-case circuit breaker (MCCB)
Frame T7L 1000
Rated current 1000 A
Number of poles 4
Trip unit PR332/P LSIG
Protection functions LSIG – long-time, short-time, instantaneous and earth-fault
Long-time protection adjustment 0.4–1 × In (400–1000 A)
Short-circuit protection adjustment 1.5–15 × In
Neutral protection settings OFF / 50% / 100% / 150% / 200%
Rated operational voltage up to 690 V AC
Ultimate short-circuit breaking capacity Icu at 220–230 V AC 200 kA
Ultimate short-circuit breaking capacity Icu at 380–415 V AC 120 kA
Ultimate short-circuit breaking capacity Icu at 440 V AC 100 kA
Ultimate short-circuit breaking capacity Icu at 500 V AC 85 kA
Ultimate short-circuit breaking capacity Icu at 690 V AC 50 kA
Installation Fixed
Terminal connection Front
Dimensions (H × W × D) approx. 268 × 235 × 154 mm
Weight approx. 9.9 kg

Frequently Asked Questions

What is the ABB 1SDA062815R1 used for?

The ABB 1SDA062815R1 is a 1000 A four-pole moulded-case circuit breaker used to protect and switch high-current low-voltage electrical distribution systems against overloads, short circuits and earth faults.

What trip unit is fitted to the ABB T7L 1000 1SDA062815R1?

The circuit breaker is equipped with an ABB PR332/P LSIG electronic trip unit, providing long-time, short-time, instantaneous and earth-fault protection functions.

What is the breaking capacity of the T7L 1000?

The T7L 1000 has a rated ultimate short-circuit breaking capacity of 120 kA at 380–415 V AC, with breaking capacities of up to 200 kA at 220–230 V AC.

Why does the 1SDA062815R1 have four poles?

The four-pole configuration enables the circuit breaker to switch three phase conductors together with the neutral conductor, making it suitable for three-phase and neutral low-voltage distribution systems.

Where is this circuit breaker typically installed?

The breaker is typically installed in low-voltage switchboards, industrial distribution panels, power distribution centres and major commercial or infrastructure systems requiring high-current protection and high short-circuit breaking performance.

Trusted Protection from ABB

ABB Tmax moulded-case circuit breakers are widely used in industrial, commercial and infrastructure power distribution systems, providing dependable circuit protection, flexible electronic trip functionality and high short-circuit interruption performance.