1SDA062810R1 ABB T7L 1000 PR231/P LS/I 1000 A 4-Pole MCCB

1SDA062810R1 ABB T7L 1000 PR231/P LS/I 1000 A 4-Pole MCCB

ABB 1SDA062810R1 is a SACE Tmax T7L 1000 A four-pole fixed moulded case circuit breaker with front terminals, a PR231/P LS/I electronic trip unit and 120 kA ultimate breaking capacity at 380–415 V AC.

SKU: 1SDA062810R1MPN: 1SDA062810R1
Price
List Price £12,152.64 ex VAT
Your Price (ex VAT) Save 25%
£9,114.48 25% OFF
You save £3,038.16 per unit
Manufacturer Lead Time Estimated Delivery 10 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £9,114.48
Trade pricing is personalised to your account

Manufacturer Lead Time

£9,114.48

Why Choose the ABB T7L 1000 1SDA062810R1 Circuit Breaker?

The ABB 1SDA062810R1 is a high-performance SACE Tmax T7L moulded case circuit breaker (MCCB) designed for protection and control of demanding low-voltage power distribution systems. Identified by ABB as T7L 1000 PR231/P LS/I In=1000A 4p F F, it combines a 1000 A rated current with the PR231/P electronic trip unit and a four-pole fixed configuration.

The T7L performance level provides an ultimate short-circuit breaking capacity of 120 kA at 380–415 V AC, making this breaker suitable for industrial installations with high prospective fault currents. Its PR231/P LS/I electronic trip unit provides adjustable long-time overload protection together with instantaneous short-circuit protection for dependable protection of high-current distribution circuits.

This configuration is a four-pole, fixed circuit breaker with front terminals and a manual operating mechanism. The long-time protection threshold is adjustable from 400–1000 A, while the instantaneous protection threshold is adjustable from 1500–12000 A, providing flexibility when coordinating the breaker with cables, feeders and other protective devices.

Key Advantages

  • High-performance 1000 A moulded case circuit breaker for demanding power distribution systems.
  • 120 kA ultimate breaking capacity at 380–415 V AC for high prospective fault levels.
  • PR231/P LS/I electronic trip unit for adjustable overload and short-circuit protection.
  • Long-time protection adjustable across 400–1000 A.
  • Instantaneous short-circuit protection adjustable across 1500–12000 A.
  • Four-pole configuration suitable for three-phase four-wire distribution systems.
  • Fixed installation with front terminals for straightforward switchboard integration.

Key Features

  • ABB SACE Tmax T7L 1000 series.
  • 1000 A rated uninterrupted current.
  • PR231/P LS/I electronic protection trip unit.
  • Long-time overload (L) protection.
  • Instantaneous short-circuit (I) protection.
  • 400–1000 A long-time protection adjustment range.
  • 1500–12000 A instantaneous protection adjustment range.
  • 120 kA Icu at 380–415 V AC.
  • Four-pole (4P) construction.
  • Neutral protection selectable between OFF / 50% / 100%.
  • Fixed (F) installation with front terminals (F).
  • Manual operating configuration.

Adjustable LS/I Protection for High-Current Power Distribution

The ABB SACE Tmax T7L range is designed for high-current low-voltage distribution systems where substantial short-circuit interruption capability is required. The 1SDA062810R1 combines a 1000 A rating with an ultimate breaking capacity of 120 kA at 380–415 V AC, providing robust protection for industrial feeders and distribution assemblies with high prospective fault levels.

The integrated PR231/P LS/I electronic trip unit provides adjustable long-time overload protection from 0.4–1 × In and instantaneous short-circuit protection from 1.5–12 × In. This combination allows the breaker to protect against both sustained overload conditions and severe short circuits, while its four-pole construction supports three-phase four-wire distribution systems requiring neutral switching and configurable neutral protection.

Typical Applications

  • Industrial low-voltage power distribution systems.
  • Main and sub-main electrical switchboards.
  • Three-phase four-wire distribution systems.
  • High-current feeder and cable protection.
  • Manufacturing and process plant power systems.
  • Commercial and infrastructure distribution boards.
  • Transformer and installation protection.
  • OEM switchgear and electrical panel assemblies.

Technical Specifications

Series SACE Tmax T7
ABB order code 1SDA062810R1
Product type Moulded case circuit breaker (MCCB)
Frame / breaker size T7 1000
Short-circuit performance level L
Rated current (In) 1000 A
Rated uninterrupted current (Iu) 1000 A
Long-time protection adjustment range 400–1000 A
Rated operational voltage up to 690 V AC
Rated insulation voltage 1000 V
Rated impulse withstand voltage 8 kV
Ultimate short-circuit breaking capacity (Icu) 200 kA at 220–230 V AC
Service short-circuit breaking capacity (Ics) 120 kA at 380–415 V AC
Rated short-time withstand current (Icw) 20 kA for 1 s
Number of poles 4
Trip unit PR231/P LS/I electronic trip unit
Protection functions Long-time overload (L) and instantaneous short-circuit (I)
Long-time protection adjustment 0.4–1 × In
Instantaneous protection adjustment 1.5–12 × In
Instantaneous protection range 1500–12000 A
Neutral protection settings OFF / 50% / 100%
Installation Fixed
Terminal configuration Front terminals
Operating configuration Manual
Electrical durability 2000 operating cycles
Mechanical durability 10000 operating cycles
Power loss 30 W per pole at rated operating conditions
Dimensions (H × W × D) 268 × 280 × 154 mm
Net weight 12.5 kg
GTIN / EAN 8015644653590
Standard IEC
Application Power distribution and high-current circuit protection
Product group 310511 – T-Max T4 - T8

Frequently Asked Questions

What is the ABB 1SDA062810R1 used for?

The ABB 1SDA062810R1 is a 1000 A four-pole moulded case circuit breaker designed to protect high-current low-voltage power distribution circuits against overload and short-circuit conditions.

What breaking capacity does the ABB T7L 1000 1SDA062810R1 provide?

The T7L configuration provides an ultimate short-circuit breaking capacity of 120 kA at 380–415 V AC, with breaking capacity varying according to the system voltage.

Which trip unit is fitted to the ABB 1SDA062810R1?

The circuit breaker is equipped with an ABB PR231/P LS/I electronic trip unit, providing adjustable long-time overload and instantaneous short-circuit protection.

What is the protection adjustment range of the ABB 1SDA062810R1?

Long-time overload protection is adjustable from 400–1000 A, while instantaneous short-circuit protection is adjustable from 1500–12000 A.

What does LS/I mean on the ABB PR231/P trip unit?

LS/I identifies the protection characteristics of the PR231/P release, providing adjustable long-time overload protection together with instantaneous short-circuit protection for power distribution applications.

Trusted ABB Power Distribution Protection

ABB SACE Tmax moulded case circuit breakers combine high interruption performance with adjustable electronic protection and flexible installation configurations for dependable protection and control of demanding industrial and commercial power distribution systems.