1SDA062802R1 ABB T7L 1000 PR231/P LS/I 1000 A 3-Pole MCCB

1SDA062802R1 ABB T7L 1000 PR231/P LS/I 1000 A 3-Pole MCCB

ABB 1SDA062802R1 is a SACE Tmax T7L 1000 A three-pole fixed moulded case circuit breaker with front terminals, lever operation, PR231/P LS/I electronic protection and 120 kA ultimate breaking capacity at 415 V AC.

SKU: 1SDA062802R1Alt SKU: T7L1000 PR231LS/IMPN: 1SDA062802R1
Price
List Price £9,839.29 ex VAT
Your Price (ex VAT) Save 25%
£7,379.47 25% OFF
You save £2,459.82 per unit
Manufacturer Lead Time Estimated Delivery 10 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £7,379.47
Trade pricing is personalised to your account

Manufacturer Lead Time

£7,379.47

Why Choose the ABB T7L 1000 PR231/P LS/I 1SDA062802R1 Circuit Breaker?

The ABB 1SDA062802R1 is a high-performance SACE Tmax T7L 1000 moulded case circuit breaker (MCCB) designed for protection and switching in demanding low-voltage power distribution systems. This configuration combines a 1000 A rated current, three-pole construction and the ABB PR231/P LS/I solid-state electronic trip unit for dependable overload and short-circuit protection.

As part of the ABB SACE Tmax T7 series, the T7L 1000 is engineered for commercial and industrial power distribution where high fault-breaking capability is required. The L performance level provides a rated ultimate short-circuit breaking capacity of 120 kA at 415 V AC, making it suitable for installations with substantial prospective fault currents.

The 1SDA062802R1 is supplied as a three-pole fixed circuit breaker with front terminals and a lever operating mechanism. Its PR231/P LS/I electronic release provides long-time overload, short-time short-circuit and instantaneous short-circuit protection, with an adjustable current range of 400–1000 A for matching protection to the requirements of the distribution circuit.

Key Advantages

  • High-performance ABB SACE Tmax T7L moulded case circuit breaker.
  • 1000 A rated current for high-current power distribution.
  • 120 kA ultimate short-circuit breaking capacity at 415 V AC.
  • PR231/P LS/I electronic trip unit for overload and short-circuit protection.
  • 400–1000 A adjustable current range for application flexibility.
  • Three-pole fixed configuration with front terminals.
  • Manual lever operating mechanism for straightforward local operation.

Key Features

  • ABB SACE Tmax T7L 1000 series.
  • 1000 A rated current.
  • Three-pole (3P) construction.
  • PR231/P LS/I solid-state electronic release.
  • Long-time overload protection.
  • Short-time short-circuit protection.
  • Instantaneous short-circuit protection.
  • 400–1000 A electronic trip adjustment range.
  • L high-breaking-capacity performance level.
  • 120 kA Icu at 415 V AC.
  • Fixed installation with front terminals.
  • Manual lever operating mechanism.

Reliable Protection for High-Current Power Distribution

The ABB SACE Tmax T7 platform is designed for commercial and industrial low-voltage distribution systems where reliable protection against overloads and short circuits is essential. The T7L performance level provides a substantial 120 kA ultimate breaking capacity at 415 V AC, helping the breaker safely interrupt severe prospective fault currents.

The PR231/P LS/I electronic trip unit combines long-time overload protection with short-time and instantaneous short-circuit protection. Its adjustable 400–1000 A current range supports coordination with the protected feeder, cables and downstream equipment, providing flexible protection for high-current distribution installations.

Typical Applications

  • Industrial low-voltage power distribution systems.
  • Main and feeder protection in electrical switchboards.
  • Commercial and industrial distribution installations.
  • Manufacturing and process-industry power systems.
  • High-current plant and machinery distribution.
  • Installations with high prospective short-circuit currents.
  • Fixed switchgear requiring high fault-breaking performance.

Technical Specifications

Series SACE Tmax T7
Order code 1SDA062802R1
EAN 8015644653514
Product type Moulded case circuit breaker (MCCB)
Rated current (In) 1000 A
Electronic trip adjustment range 400–1000 A
Number of poles 3
Trip unit PR231/P LS/I solid-state release
Protection functions Long-time, short-time and instantaneous
Short-circuit performance level L
Rated ultimate short-circuit breaking capacity (Icu) at 415 V AC 120 kA
Installation Fixed
Terminal connection Front terminals
Operating mechanism Lever
Electrical durability 2000 operating cycles
Mechanical durability 10,000 operating cycles
Dimensions (H × W × D) 268 × 210 × 154 mm
Weight 9.7 kg
ABB product group 310511-T-Max T4 - T8

Frequently Asked Questions

What is the ABB 1SDA062802R1?

The ABB 1SDA062802R1 is a SACE Tmax T7L 1000 three-pole fixed moulded case circuit breaker rated at 1000 A and fitted with a PR231/P LS/I solid-state electronic trip unit.

What is the breaking capacity of the ABB T7L 1000 1SDA062802R1?

The T7L 1000 has a rated ultimate short-circuit breaking capacity of 120 kA at 415 V AC, providing high fault-interruption capability for demanding distribution systems.

What protection functions does the PR231/P LS/I trip unit provide?

The PR231/P LS/I electronic trip unit provides long-time overload, short-time short-circuit and instantaneous short-circuit protection.

What is the current adjustment range of the ABB 1SDA062802R1?

The T7L 1000 PR231/P LS/I configuration provides an adjustable current range of 400–1000 A, allowing protection to be matched to the requirements of the distribution circuit.

Is the ABB 1SDA062802R1 fixed or withdrawable?

The 1SDA062802R1 is a fixed three-pole circuit breaker with front terminals and a lever operating mechanism.

Trusted ABB Power Distribution Protection

ABB SACE Tmax T7 moulded case circuit breakers combine high-current capability, electronic protection and substantial short-circuit breaking performance for dependable protection of demanding commercial and industrial low-voltage distribution systems.