1sda062756r1  t7s 1000 pr331/p lsig in=1000a 3 pole abb mccb

1sda062756r1 t7s 1000 pr331/p lsig in=1000a 3 pole abb mccb

ABB T7S 1000 PR331/P LSIG three-pole moulded case circuit breaker with 1000 A rated current, front terminals and stored energy operating mechanism for industrial power distribution.

SKU: 1SDA062756R1Alt SKU: T7S 1000 PR331/P LSIG In=1000A 3p F F MMPN: 1SDA062756R1
Price
List Price £7,897.66 ex VAT
Your Price (ex VAT) Save 25%
£5,923.25 25% OFF
You save £1,974.42 per unit
Manufacturer Lead Time Estimated Delivery 10 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £5,923.25
Trade pricing is personalised to your account

Manufacturer Lead Time

£5,923.25

Why Choose the ABB T7S 1000 PR331/P LSIG In=1000A 3P F F M?

The ABB 1SDA062756R1 is a high-performance SACE Tmax T7S moulded case circuit breaker (MCCB) designed to provide dependable protection for low voltage power distribution systems. Built for demanding industrial, commercial and infrastructure applications, this fixed three-pole circuit breaker delivers reliable protection against overloads, short circuits and earth faults in high-current electrical installations.

Equipped with the advanced PR331/P LSIG electronic trip unit, the breaker provides Long-time, Short-time, Instantaneous and Ground fault protection for comprehensive fault detection and selective coordination. Its stored energy operating mechanism supports dependable switching performance, making it suitable for critical switchboards, distribution panels, transformers and generator protection systems.

With a 1000 A rated current, 690 V AC rated operational voltage and 50 kA breaking capacity at 400/415 V AC, the ABB T7S is ideal for high-current power distribution systems where safety, uptime and long service life are essential.

Key Advantages

  • High-performance ABB SACE Tmax T7S moulded case circuit breaker.
  • 1000 A rated current for demanding power distribution applications.
  • Three-pole fixed construction with front terminal connections.
  • Advanced PR331/P LSIG electronic trip unit.
  • Stored energy operating mechanism for dependable switching.
  • Ground fault protection for enhanced safety and selectivity.

Key Features

  • ABB SACE Tmax T7S series.
  • Product code: 1SDA062756R1.
  • 1000 A rated uninterrupted current.
  • Three-pole fixed construction.
  • PR331/P LSIG solid-state electronic release.
  • Front terminal connections.
  • Stored energy operating mechanism.
  • Rated operational voltage up to 690 V AC.
  • High electrical and mechanical durability.
  • Suitable for switchboards and distribution panels.

Reliable Protection for High Current Power Distribution

The ABB SACE Tmax T7S range is engineered to protect low voltage electrical installations from overload, short-circuit and earth fault conditions while maintaining excellent operational continuity. The PR331/P LSIG electronic trip unit provides comprehensive protection settings that support selectivity and coordination across complex distribution networks.

Its three-pole construction, front terminal arrangement and stored energy operating mechanism make this MCCB suitable for panel builders, electrical contractors and industrial operators requiring dependable performance in demanding power distribution systems.

Typical Applications

  • Main low voltage distribution boards.
  • Industrial switchboards.
  • Commercial electrical installations.
  • Motor control centres.
  • Generator protection.
  • Transformer protection.
  • Infrastructure projects.
  • Manufacturing facilities.

Technical Specifications

Tick the specs you need, then view products that match.

Current 1000 A
Phase Three Phase
Poles 3-pole
Device Type MCCB
Breaking Capacity 50 kA
Trip Unit Electronic
Manufacturer ABB
Series SACE Tmax T
Model T7S 1000 PR331/P LSIG In=1000A 3P F F M
Product code 1SDA062756R1
Product type Moulded case circuit breaker (MCCB)
Rated current (In) 1000 A
Rated uninterrupted current (Iu) 1000 A
Number of poles 3
Rated operational voltage Up to 690 V AC
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 8 kV
Breaking capacity (Icu) 50 kA at 400/415 V AC
Breaking capacity (Ics) 50 kA at 400/415 V AC
Short-time withstand current (Icw) 20 kA for 1 second
Trip unit PR331/P LSIG electronic release
Protection functions Long-time, Short-time, Instantaneous and Ground fault protection
Connection type Front terminals
Mounting Fixed
Operating mechanism Stored energy mechanism
Electrical durability 2000 cycles
Mechanical durability 10000 cycles
Power loss 30 W per pole at rated operating conditions
Standards IEC 60947-2
Dimensions (H × W × D) 268 × 210 × 178 mm
Weight Approx. 11 kg

Frequently Asked Questions

What is the ABB 1SDA062756R1 used for?

This moulded case circuit breaker protects low voltage power distribution systems against overloads, short circuits and earth faults in industrial and commercial installations.

What protection does the PR331/P LSIG trip unit provide?

The PR331/P LSIG electronic trip unit provides Long-time, Short-time, Instantaneous and Ground fault protection for comprehensive circuit protection and improved selectivity.

How many poles does this circuit breaker have?

This model features a three-pole fixed configuration with front terminal connections.

What operating mechanism does this breaker use?

This version uses a stored energy operating mechanism, supporting reliable switching operation in demanding installations.

What is the rated current of this breaker?

The breaker has a rated uninterrupted current of 1000 A.

Trusted by Electrical Professionals Worldwide

ABB SACE Tmax moulded case circuit breakers are trusted by electrical engineers, panel builders and industrial operators worldwide for delivering dependable protection, high interruption performance and long-term reliability in critical electrical distribution systems.