1SDA062730R1 ABB T7V 800 PR231/P LS/I 4P 800 A FFM Circuit Breaker

1SDA062730R1 ABB T7V 800 PR231/P LS/I 4P 800 A FFM Circuit Breaker

ABB 1SDA062730R1 is an 800 A four-pole SACE Tmax T7V fixed moulded case circuit breaker with front terminals, a stored-energy operating mechanism, PR231/P LS/I electronic protection and 150 kA ultimate breaking capacity at 380-415 V AC.

SKU: 1SDA062730R1MPN: 1SDA062730R1
Price
List Price £12,026.10 ex VAT
Your Price (ex VAT) Save 25%
£9,019.58 25% OFF
You save £3,006.53 per unit
Manufacturer Lead Time Estimated Delivery 10 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £9,019.58
Trade pricing is personalised to your account

Manufacturer Lead Time

£9,019.58

Why Choose the ABB 1SDA062730R1 T7V 800 Circuit Breaker?

The ABB 1SDA062730R1 is a high-performance four-pole moulded case circuit breaker (MCCB) from the ABB SACE Tmax T7 range, engineered for demanding low-voltage power distribution applications. Identified as T7V 800 PR231/P LS/I In=800A 4P F F M, it combines an 800 A rated current with ABB's PR231/P electronic trip unit and the high short-circuit interruption performance of the T7V platform.

The PR231/P LS/I electronic trip unit provides adjustable overload and short-circuit protection for power distribution circuits. The overload setting can be adjusted from 0.4–1 × In, equivalent to 320–800 A, while the short-circuit release provides an adjustable range of 1.5–12 × In. Neutral protection can also be selected at OFF, 50% or 100% for the four-pole configuration.

The 1SDA062730R1 is supplied as a four-pole fixed circuit breaker with front terminals and a stored-energy operating mechanism. Its T7V construction provides an ultimate short-circuit breaking capacity of 150 kA at 380–415 V AC, making it particularly suitable for industrial switchboards, main distribution assemblies and high-current feeder circuits with substantial prospective fault levels.

Key Advantages

  • High-performance ABB SACE Tmax T7V moulded case circuit breaker.
  • 800 A rated current for high-current low-voltage distribution.
  • High 150 kA ultimate breaking capacity at 380–415 V AC.
  • PR231/P LS/I electronic trip unit with adjustable protection settings.
  • Overload protection adjustable across 320–800 A.
  • Four-pole configuration with selectable neutral protection.
  • Stored-energy operating mechanism with optional motor-drive capability.

Key Features

  • ABB SACE Tmax T7V 800 circuit breaker.
  • 800 A rated uninterrupted current.
  • Four-pole (4P) configuration.
  • PR231/P LS/I electronic trip unit.
  • Adjustable long-time overload protection.
  • Adjustable short-circuit protection.
  • Overload setting range of 0.4–1 × In.
  • Short-circuit setting range of 1.5–12 × In.
  • Neutral protection selectable between OFF / 50% / 100%.
  • Fixed (F) circuit breaker execution.
  • Front terminals (F).
  • Stored-energy operating mechanism (M).

PR231/P LS/I Electronic Protection and Stored-Energy Operation

The PR231/P LS/I electronic trip unit monitors circuit current and provides adjustable protection against overload and short-circuit conditions. Its overload setting range of 320–800 A allows the protection threshold to be matched to the protected circuit, while the adjustable short-circuit function enables rapid interruption of higher fault currents and supports coordination with other protection devices.

The stored-energy operating mechanism provides controlled breaker operation and can be combined with an optional motor drive where electrically operated switching is required. Together with the T7V platform's 150 kA Icu at 380–415 V AC, the four-pole construction and selectable neutral protection make the ABB 1SDA062730R1 well suited to demanding three-phase and neutral power distribution systems.

Typical Applications

  • Industrial low-voltage main distribution boards.
  • High-current feeder and sub-main protection.
  • Four-pole three-phase and neutral distribution systems.
  • Manufacturing and process plant switchboards.
  • Commercial building electrical distribution.
  • Infrastructure and utility distribution assemblies.
  • Installations with high prospective short-circuit currents.

Technical Specifications

Series SACE Tmax T7
Order code / MPN 1SDA062730R1
Product group 310511-T-Max T4 - T8
Product type Moulded case circuit breaker
Breaker designation T7V 800
Frame size T7
Rated uninterrupted current (Iu) 800 A
Number of poles 4
Trip unit PR231/P LS/I
Trip technology Electronic / solid-state
Overload release setting range 320–800 A
Overload adjustment 0.4–1 × In
Short-circuit adjustment 1.5–12 × In
Short-circuit release adjustment range 800–8000 A
Neutral protection setting OFF / 50% / 100%
Rated voltage 690 V AC
Ultimate breaking capacity (Icu) at 220–230 V AC 200 kA
Ultimate breaking capacity (Icu) at 380–415 V AC 150 kA
Ultimate breaking capacity (Icu) at 440 V AC 130 kA
Ultimate breaking capacity (Icu) at 500 V AC 100 kA
Ultimate breaking capacity (Icu) at 690 V AC 60 kA
Installation type Fixed
Terminal configuration Front terminals
Main circuit connection Bolted connection
Operating mechanism Stored-energy mechanism
Motor drive Optional
Degree of protection IP20
EAN 8015644652791
Application Low-voltage power distribution protection

Frequently Asked Questions

What is the ABB 1SDA062730R1?

The ABB 1SDA062730R1 is an 800 A four-pole SACE Tmax T7V moulded case circuit breaker with a PR231/P LS/I electronic trip unit, fixed installation, front terminals and a stored-energy operating mechanism.

What protection does the ABB 1SDA062730R1 provide?

The PR231/P LS/I trip unit provides adjustable overload and short-circuit protection. The overload setting is adjustable from 0.4–1 × In, while short-circuit protection is adjustable from 1.5–12 × In.

What is the breaking capacity of the ABB 1SDA062730R1?

The T7V 800 provides an ultimate short-circuit breaking capacity of 150 kA at 380–415 V AC. Its voltage-dependent ratings include 200 kA at 220–230 V AC, 130 kA at 440 V AC, 100 kA at 500 V AC and 60 kA at 690 V AC.

What is the rated current of the ABB 1SDA062730R1?

The ABB 1SDA062730R1 has a rated uninterrupted current of 800 A, with the electronic overload release adjustable between 320–800 A.

What does F F M mean on the ABB T7V 800?

The F F M designation identifies a fixed circuit breaker with front terminals and a stored-energy operating mechanism. The breaker also supports an optional motor drive for electrically operated switching.

Trusted ABB Circuit Protection

ABB SACE Tmax moulded case circuit breakers combine high short-circuit interruption performance with electronic protection and flexible operating mechanisms, supporting dependable low-voltage power distribution across demanding industrial, commercial and infrastructure applications.