Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB 1SDA062714R1 is a T7V800 800 A four-pole fixed moulded case circuit breaker with a PR231/P LS/I electronic trip unit and high breaking capacity for low-voltage power distribution.
£8,199.59
The ABB T7V800 PR231/P-LS/I is a high-performance moulded case circuit breaker (MCCB) designed for dependable protection and switching of low-voltage power distribution systems. As part of the proven ABB SACE Tmax T7 series, this breaker combines an 800 A current rating with an electronic PR231/P trip unit for accurate overload, short-circuit and instantaneous protection.
This model is supplied in a 4-pole fixed configuration with front terminals, making it suitable for industrial switchboards, distribution panels and electrical installations where reliable four-pole circuit protection is required. The PR231/P-LS/I electronic release provides adjustable long-time, short-time and instantaneous protection functions for effective coordination with downstream electrical equipment.
With a rated current of 800 A, the T7V breaking-capacity version provides high fault interruption performance, including an ultimate short-circuit breaking capacity of 150 kA at 380–415 V AC. Its robust construction and high breaking capacity make it particularly suitable for demanding industrial and commercial power-distribution applications.
Moulded case circuit breakers such as the ABB Tmax T7 provide protection against overloads and short circuits while also providing a dependable means of isolating electrical circuits. Electronic trip technology allows protection thresholds to be adjusted to suit the installation and improve selectivity between upstream and downstream protective devices.
The PR231/P release used in this breaker provides LS/I protection functions for power-distribution applications. Combined with the T7V breaker’s high interruption capability, this makes the unit suitable for installations where substantial prospective fault currents may occur.
| Series | SACE Tmax T7 |
|---|---|
| ABB order code | 1SDA062714R1 |
| Product type | Moulded case circuit breaker |
| Rated current | 800 A |
| Number of poles | 4 |
| Trip unit | PR231/P |
| Protection functions | LS/I |
| Mounting type | Fixed |
| Terminal arrangement | Front terminals |
| Ultimate breaking capacity (Icu) at 220–230 V AC | 200 kA |
| Ultimate breaking capacity (Icu) at 380–415 V AC | 150 kA |
| Ultimate breaking capacity (Icu) at 440 V AC | 130 kA |
| Ultimate breaking capacity (Icu) at 500 V AC | 100 kA |
| Ultimate breaking capacity (Icu) at 690 V AC | 60 kA |
| Dimensions (H × W × D) | approx. 268 × 235 × 154 mm |
| Weight | approx. 9.9 kg |
This Tmax T7V moulded case circuit breaker is designed to protect and switch high-current low-voltage power distribution circuits in industrial and commercial electrical systems.
The ABB T7V800 PR231/P-LS/I has a rated current of 800 A.
The electronic PR231/P LS/I release provides long-time overload, short-time short-circuit and instantaneous short-circuit protection.
The T7V800 has an ultimate short-circuit breaking capacity of 150 kA at 380–415 V AC.
This version is a 4-pole fixed circuit breaker with front terminals, designed for installation in low-voltage switchboards and power-distribution panels.
ABB SACE Tmax circuit breakers are widely used in industrial, commercial and infrastructure electrical systems to provide dependable circuit protection, high breaking capacity and flexible power-distribution performance.