1SDA062712R1 ABB T7V 800 800 A 3-Pole PR332/P LSIRc Circuit Breaker

1SDA062712R1 ABB T7V 800 800 A 3-Pole PR332/P LSIRc Circuit Breaker

ABB 1SDA062712R1 T7V 800 fixed three-pole 800 A moulded-case circuit breaker with front terminals, PR332/P LSIRc electronic protection and 150 kA ultimate breaking capacity at 380–415 V AC.

SKU: 1SDA062712R1MPN: 1SDA062712R1
Price
List Price £10,897.70 ex VAT
Your Price (ex VAT) Save 25%
£8,173.28 25% OFF
You save £2,724.43 per unit
Manufacturer Lead Time Estimated Delivery 10 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £8,173.28
Trade pricing is personalised to your account

Manufacturer Lead Time

£8,173.28

Why Choose the ABB T7V 800 1SDA062712R1 Circuit Breaker?

The ABB 1SDA062712R1 is a high-performance SACE Tmax T7V 800 moulded-case circuit breaker designed for demanding low-voltage power distribution systems. Rated at 800 A, this three-pole breaker combines fixed installation, front terminals and an advanced PR332/P LSIRc electronic trip unit for overload, selective short-circuit, instantaneous short-circuit and residual-current protection.

The T7V performance level provides exceptional fault-clearing capability, including a rated ultimate short-circuit breaking capacity of 150 kA at 380–415 V AC. The breaker is rated for operation up to 690 V AC, making it suitable for high-capacity industrial and commercial distribution networks where substantial prospective fault currents may be present.

The PR332/P LSIRc trip unit combines adjustable long-time, short-time and instantaneous overcurrent protection with an integrated residual-current function. With an 800 A rated current, three-pole construction, fixed mounting and front connections, the 1SDA062712R1 provides a comprehensive protection solution for main switchboards, distribution feeders and critical industrial power systems.

Key Advantages

  • High-performance 800 A moulded-case circuit breaker for demanding low-voltage distribution systems.
  • PR332/P LSIRc electronic trip unit combines adjustable overcurrent and residual-current protection.
  • 150 kA ultimate breaking capacity at 380–415 V AC for installations with very high prospective fault currents.
  • Residual-current protection provides additional detection of current leakage to earth.
  • Three-pole fixed configuration with front terminals for straightforward switchboard integration.
  • Part of ABB's established SACE Tmax T7 moulded-case circuit-breaker platform.

Key Features

  • ABB SACE Tmax T7V 800 circuit breaker.
  • 800 A rated current.
  • Three-pole configuration.
  • PR332/P LSIRc electronic trip unit.
  • Long-time overload protection (L).
  • Short-time delayed protection (S).
  • Instantaneous short-circuit protection (I).
  • Residual-current protection (Rc).
  • 150 kA Icu at 380–415 V AC.
  • Fixed installation with front terminals.

Advanced LSIRc Protection for High-Fault-Level Distribution

The PR332/P LSIRc electronic trip unit provides multiple protection functions within a single circuit-breaker platform. Long-time protection responds to sustained overloads, short-time protection supports selective coordination during short circuits, instantaneous protection provides rapid interruption of severe faults, and the residual-current function provides additional protection by monitoring current leakage towards earth.

Combined with the T7V breaker's 150 kA Icu at 380–415 V AC, these protection functions make the 1SDA062712R1 particularly suitable for high-capacity distribution networks where both substantial short-circuit performance and residual-current monitoring are required. Its fixed construction and front bolted connections provide a robust arrangement for permanent integration into industrial and commercial switchboards.

Typical Applications

  • Industrial low-voltage main switchboards.
  • Main and sub-main power distribution systems.
  • High-fault-level electrical distribution networks.
  • Distribution systems requiring residual-current protection.
  • Manufacturing, process and infrastructure electrical installations.
  • OEM switchgear requiring adjustable electronic LSIRc protection.

Technical Specifications

Series SACE Tmax T7
ABB order code 1SDA062712R1
Product type Moulded-case circuit breaker
Performance level V
Rated current (In) 800 A
Rated uninterrupted current (Iu) 800 A
Number of poles 3
Trip unit PR332/P LSIRc
Trip unit technology Electronic
Protection functions LSIRc
Long-time protection L
Short-time delayed protection S
Instantaneous protection I
Residual-current protection Rc
Overload protection setting range 320–800 A
Short-time delayed short-circuit setting range 480–8000 A
Instantaneous short-circuit setting range 1200–12000 A
Residual-current setting range 0.2–1 × In
Rated operational voltage 690 V AC
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 8 kV
Icu at 220–230 V AC 200 kA
Icu at 380–415 V AC 150 kA
Icu at 440 V AC 130 kA
Icu at 500 V AC 100 kA
Icu at 690 V AC 60 kA
Ics at 380–415 V AC 150 kA
Rated short-time withstand current (Icw), 1 s 15 kA
Mounting type Fixed
Terminal connection Front
Main circuit connection Bolted connection
Degree of protection IP20
Electrical durability 3000 cycles
Mechanical durability 10000 cycles
Power loss at rated conditions 32 W per pole
Product width 210 mm
Product height 268 mm
Product depth 154 mm
Net weight 9.7 kg
Standards IEC
EAN 8015644652616
Customs tariff number 85362090
ABB product group 310511-T-Max T4 - T8

Frequently Asked Questions

What is the ABB 1SDA062712R1?

The ABB 1SDA062712R1 is a Tmax T7V 800 three-pole moulded-case circuit breaker rated at 800 A, with fixed front terminals and a PR332/P LSIRc electronic trip unit.

What does LSIRc mean on the ABB PR332/P trip unit?

LSIRc combines long-time overload protection (L), short-time delayed protection (S), instantaneous short-circuit protection (I) and residual-current protection (Rc).

What is the breaking capacity of the ABB T7V 800 1SDA062712R1?

The T7V 800 has a rated ultimate short-circuit breaking capacity (Icu) of 150 kA at 380–415 V AC. Its Icu is 200 kA at 220–230 V AC, 130 kA at 440 V AC, 100 kA at 500 V AC and 60 kA at 690 V AC.

What are the overcurrent adjustment ranges on the ABB 1SDA062712R1?

The PR332/P LSIRc configuration provides an overload setting range of 320–800 A, a short-time delayed short-circuit setting range of 480–8000 A and an instantaneous short-circuit setting range of 1200–12000 A.

What mounting and terminal configuration does the ABB 1SDA062712R1 use?

The 1SDA062712R1 is a fixed three-pole circuit breaker with front-positioned bolted main connections, designed for permanent integration into compatible low-voltage switchboards and power distribution assemblies.

Trusted by Electrical Professionals Worldwide

ABB SACE Tmax circuit breakers provide industrial and commercial power distribution systems with high breaking performance, adjustable electronic protection and integrated protection options for demanding low-voltage switchgear applications.