1SDA062703R1 ABB T7L 800 PR332/P LSIG 800 A 4-Pole MCCB

1SDA062703R1 ABB T7L 800 PR332/P LSIG 800 A 4-Pole MCCB

ABB 1SDA062703R1 is a SACE Tmax T7L 800 A four-pole fixed moulded case circuit breaker with front terminals, a PR332/P LSIG electronic trip unit, stored-energy operating mechanism and 120 kA ultimate breaking capacity at 380–415 V AC.

SKU: 1SDA062703R1MPN: 1SDA062703R1
Price
List Price £14,168.20 ex VAT
Your Price (ex VAT) Save 25%
£10,626.15 25% OFF
You save £3,542.05 per unit
Manufacturer Lead Time Estimated Delivery 10 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £10,626.15
Trade pricing is personalised to your account

Manufacturer Lead Time

£10,626.15

Why Choose the ABB T7L 800 1SDA062703R1 Circuit Breaker?

The ABB 1SDA062703R1 is a high-performance SACE Tmax T7L moulded case circuit breaker (MCCB) designed for protection and control of demanding low-voltage power distribution systems. Identified by ABB as T7L 800 PR332/P LSIG In=800A 4p F F M, it combines an 800 A rated current with the advanced PR332/P electronic trip unit and a stored-energy operating mechanism.

The T7L performance level provides an ultimate short-circuit breaking capacity of 120 kA at 380–415 V AC, making the breaker suitable for industrial installations with high prospective fault currents. Its PR332/P LSIG electronic trip unit provides long-time overload (L), short-time short-circuit (S), instantaneous short-circuit (I) and earth-fault (G) protection for comprehensive power distribution protection.

This configuration is a four-pole, fixed circuit breaker with front terminals, enabling switching and protection across all four poles in suitable three-phase distribution systems with neutral conductors. The PR332/P provides adjustable protection functions, while the stored-energy operating mechanism makes the breaker suitable for sophisticated industrial switchboards and power distribution assemblies.

Key Advantages

  • High-performance 800 A moulded case circuit breaker for industrial power distribution.
  • 120 kA ultimate breaking capacity at 380–415 V AC for demanding fault levels.
  • Advanced PR332/P LSIG electronic trip unit.
  • Provides long-time, short-time, instantaneous and earth-fault protection.
  • Four-pole configuration suitable for distribution systems requiring neutral switching and protection.
  • Fixed installation with front terminals for straightforward switchboard integration.

Key Features

  • ABB SACE Tmax T7L 800 series.
  • 800 A rated current.
  • PR332/P LSIG electronic protection trip unit.
  • Long-time overload (L) protection.
  • Short-time short-circuit (S) protection.
  • Instantaneous short-circuit (I) protection.
  • Earth-fault (G) protection.
  • 120 kA Icu at 380–415 V AC.
  • Four-pole (4P) construction.
  • Fixed (F) installation with front terminals (F).
  • Stored-energy operating mechanism.
  • ABB order code 1SDA062703R1.

Comprehensive LSIG Protection for Industrial Power Distribution

Moulded case circuit breakers such as the ABB SACE Tmax T7L protect electrical distribution systems against potentially damaging overload, short-circuit and earth-fault conditions. The 1SDA062703R1 combines an 800 A rating with an ultimate breaking capacity of 120 kA at 380–415 V AC, providing robust protection for demanding industrial installations.

The integrated PR332/P LSIG electronic trip unit provides comprehensive adjustable protection. Long-time protection responds to sustained overloads, short-time protection supports selective fault coordination, instantaneous protection provides rapid response to severe short circuits, and earth-fault protection detects ground faults. Its four-pole construction additionally supports applications where the neutral conductor must form part of the circuit-breaker switching and protection arrangement.

Typical Applications

  • Industrial low-voltage power distribution systems.
  • Main and sub-main electrical switchboards.
  • Four-pole three-phase distribution systems with neutral conductors.
  • Manufacturing and process plant power systems.
  • High-current feeder and cable protection.
  • Distribution systems requiring earth-fault protection.
  • OEM switchgear and electrical panel assemblies.

Technical Specifications

Series SACE Tmax T7
ABB order code 1SDA062703R1
Product type Moulded case circuit breaker (MCCB)
Frame / breaker size T7 800
Short-circuit performance level L
Rated current 800 A
Overload protection adjustment 0.4–1 × In
Ultimate short-circuit breaking capacity (Icu) 200 kA at 220–230 V AC
Number of poles 4
Trip unit PR332/P LSIG electronic trip unit
Protection functions Long-time (L), short-time (S), instantaneous (I) and earth-fault (G)
Instantaneous protection adjustment 1.5–15 × In
Earth-fault protection adjustment 0.2–1 × In
Neutral protection settings OFF / 50% / 100% / 200%
Installation Fixed
Terminal configuration Front terminals
Operating mechanism Stored-energy mechanism
Dimensions (H × W × D) approx. 268 × 235 × 178 mm
Weight approx. 11.2 kg
Application Power distribution protection and control
Product group 310511 – T-Max T4 - T8

Frequently Asked Questions

What is the ABB 1SDA062703R1 used for?

The ABB 1SDA062703R1 is an 800 A four-pole moulded case circuit breaker designed to protect and control low-voltage power distribution circuits against overload, short-circuit and earth-fault conditions.

What breaking capacity does the ABB T7L 800 1SDA062703R1 provide?

The T7L configuration provides an ultimate short-circuit breaking capacity of 120 kA at 380–415 V AC, with breaking capacity varying according to the system voltage.

Which trip unit is fitted to the ABB 1SDA062703R1?

The circuit breaker is equipped with an ABB PR332/P LSIG electronic trip unit, providing long-time, short-time, instantaneous and earth-fault protection functions.

How many poles does the ABB 1SDA062703R1 have?

The 1SDA062703R1 is a four-pole (4P) circuit breaker, making it suitable for applications where switching and protection of the neutral conductor are required alongside the three phase conductors.

What does LSIG mean on the ABB PR332/P trip unit?

LSIG identifies long-time overload (L), short-time short-circuit (S), instantaneous short-circuit (I) and earth-fault or ground-fault (G) protection functions.

Trusted ABB Power Distribution Protection

ABB SACE Tmax moulded case circuit breakers combine high interruption performance with advanced electronic protection functions, providing dependable protection and control for demanding industrial and commercial power distribution systems.