1SDA062702R1 ABB T7L 800 PR332/P LSI 4P 800 A Circuit Breaker

1SDA062702R1 ABB T7L 800 PR332/P LSI 4P 800 A Circuit Breaker

ABB 1SDA062702R1 is an 800 A four-pole SACE Tmax T7L fixed moulded case circuit breaker with front terminals and a PR332/P electronic trip unit providing long-time, short-time and instantaneous LSI overcurrent protection.

SKU: 1SDA062702R1MPN: 1SDA062702R1
Price
List Price £12,741.83 ex VAT
Your Price (ex VAT) Save 25%
£9,556.37 25% OFF
You save £3,185.46 per unit
Manufacturer Lead Time Estimated Delivery 10 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £9,556.37
Trade pricing is personalised to your account

Manufacturer Lead Time

£9,556.37

Why Choose the ABB 1SDA062702R1 T7L 800 Circuit Breaker?

The ABB 1SDA062702R1 is a high-performance four-pole moulded case circuit breaker (MCCB) from the ABB SACE Tmax T7 range, designed for demanding low-voltage power distribution and protection applications. Identified as T7L 800 PR332/P LSI In=800A 4P F F, it combines an 800 A rated current with ABB's advanced PR332/P electronic trip unit.

The PR332/P electronic trip unit provides comprehensive LSI protection, incorporating long-time overload, short-time short-circuit and instantaneous short-circuit protection. This combination enables accurate electronic protection of cables, busbars and connected electrical equipment across a wide range of overload and fault-current conditions.

The 1SDA062702R1 is configured as a four-pole fixed circuit breaker with front terminals. As a T7L breaker, it is designed for installations requiring high short-circuit interruption performance, making it particularly suitable for main distribution boards, industrial switchboards and high-current feeder circuits.

Key Advantages

  • High-performance ABB SACE Tmax T7L moulded case circuit breaker.
  • 800 A rated current for high-current distribution applications.
  • Advanced PR332/P electronic trip unit.
  • LSI protection covering overload and multiple short-circuit fault conditions.
  • Four-pole configuration for three-phase and neutral distribution systems.
  • Fixed installation with front terminals for practical switchboard integration.
  • T7L construction designed for installations with high prospective fault currents.

Key Features

  • ABB SACE Tmax T7L 800 circuit breaker.
  • 800 A rated current.
  • Four-pole (4P) configuration.
  • PR332/P electronic trip unit.
  • LSI protection functions.
  • Long-time overload protection.
  • Short-time short-circuit protection.
  • Instantaneous short-circuit protection.
  • Fixed (F) circuit breaker execution.
  • Front terminals (F).
  • Designed for high-current low-voltage power distribution and circuit protection.

PR332/P LSI Electronic Circuit Protection

The PR332/P electronic trip unit continuously monitors current through the circuit breaker and initiates tripping when the configured protection thresholds are exceeded. The L function provides long-time protection against sustained overloads, while the S function provides short-time protection against higher fault currents with controlled intervention.

The I function adds instantaneous protection for severe short-circuit conditions requiring rapid interruption. Together, these LSI functions give the ABB 1SDA062702R1 a comprehensive overcurrent protection profile, while its four-pole construction allows the breaker to be integrated into three-phase and neutral distribution systems.

Typical Applications

  • Industrial low-voltage main distribution boards.
  • High-current feeder and sub-main protection.
  • Four-pole three-phase and neutral distribution systems.
  • Manufacturing and process plant switchboards.
  • Commercial building power distribution systems.
  • Infrastructure and utility distribution assemblies.
  • Installations requiring electronic overload and short-circuit protection.

Technical Specifications

Series SACE Tmax T7
Order code / MPN 1SDA062702R1
Product group 310511-T-Max T4 - T8
Product type Moulded case circuit breaker
Breaker designation T7L 800
Frame size T7
Rated current 800 A
Number of poles 4
Trip unit PR332/P
Trip technology Electronic
Protection functions LSI
Long-time protection L
Short-time protection S
Instantaneous protection I
Installation type Fixed
Terminal configuration Front terminals
Application Low-voltage power distribution protection

Frequently Asked Questions

What is the ABB 1SDA062702R1?

The ABB 1SDA062702R1 is an 800 A four-pole SACE Tmax T7L moulded case circuit breaker equipped with a PR332/P electronic trip unit and LSI protection.

What protection functions does the ABB 1SDA062702R1 provide?

The PR332/P trip unit provides LSI protection: long-time overload protection (L), short-time short-circuit protection (S) and instantaneous short-circuit protection (I).

What is the rated current of the ABB 1SDA062702R1?

The T7L 800 circuit breaker has a rated current of 800 A.

How many poles does the ABB 1SDA062702R1 have?

The 1SDA062702R1 has a four-pole (4P) configuration, making it suitable for low-voltage distribution systems where three phases and the neutral conductor are switched by the circuit breaker.

What does F F mean in T7L 800 PR332/P LSI 4P F F?

The F F designation identifies a fixed circuit breaker with front terminals, suitable for permanent installation within a compatible switchboard or distribution assembly.

Trusted ABB Circuit Protection

ABB SACE Tmax moulded case circuit breakers combine robust interruption technology with advanced electronic protection, supporting dependable low-voltage power distribution across demanding industrial, commercial and infrastructure applications.