1SDA062696R1 ABB T7L 800 PR332/P-LSI Rc 800 A 3P Fixed Moulded Case Circuit Breaker

1SDA062696R1 ABB T7L 800 PR332/P-LSI Rc 800 A 3P Fixed Moulded Case Circuit Breaker

ABB 1SDA062696R1 is a SACE Tmax T7L 800 A three-pole fixed moulded-case circuit breaker with front terminals, stored-energy operation and a PR332/P-LSI Rc electronic release providing overload, short-circuit and residual-current protection.

SKU: 1SDA062696R1MPN: 1SDA062696R1
Price
List Price £11,637.86 ex VAT
Your Price (ex VAT) Save 25%
£8,728.40 25% OFF
You save £2,909.47 per unit
Manufacturer Lead Time Estimated Delivery 10 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £8,728.40
Trade pricing is personalised to your account

Manufacturer Lead Time

£8,728.40

Why Choose the ABB T7L 800 PR332/P-LSI Rc 800 A 3P Fixed Circuit Breaker?

The ABB 1SDA062696R1 is a SACE Tmax T7L moulded-case circuit breaker rated at 800 A, supplied in a 3-pole fixed configuration with front terminals and an ABB PR332/P-LSI Rc electronic protection release. It is designed for demanding low-voltage power-distribution applications requiring adjustable overload and short-circuit protection together with residual-current protection.

The T7L 800 provides an 800 A rated uninterrupted current and a rated operational voltage of 690 V AC. Its L-performance level delivers a rated ultimate short-circuit breaking capacity of 120 kA at 400 V AC, 50 Hz, making it suitable for distribution systems with substantial prospective fault currents.

The PR332/P-LSI Rc release combines long-time overload, short-time and instantaneous short-circuit protection with residual-current functionality. The breaker is supplied with a stored-energy operating mechanism, fixed installation and front main-circuit terminals for integration into high-performance low-voltage switchboards.

Key Advantages

  • High-performance ABB SACE Tmax T7L moulded-case circuit breaker.
  • Rated uninterrupted current of 800 A.
  • 3-pole configuration for three-phase distribution systems.
  • PR332/P-LSI Rc electronic release with residual-current functionality.
  • Long-time, short-time and instantaneous protection functions.
  • Rated ultimate short-circuit breaking capacity of 120 kA at 400 V AC, 50 Hz.
  • Fixed construction with front main-circuit terminals.
  • Stored-energy operating mechanism for dependable breaker operation.

Key Features

  • ABB SACE Tmax T7L 800 circuit breaker.
  • 800 A rated uninterrupted current.
  • 3-pole construction.
  • PR332/P-LSI Rc electronic protection release.
  • L: Long-time overload protection.
  • S: Short-time short-circuit protection.
  • I: Instantaneous short-circuit protection.
  • Rc: Residual-current protection functionality.
  • Fixed breaker construction.
  • Front main-circuit terminals.
  • Stored-energy operating mechanism.
  • ABB order code 1SDA062696R1.

Advanced LSI Rc Protection for High-Current Distribution

The ABB PR332/P-LSI Rc electronic release combines multiple protection functions within the T7L platform. Long-time protection responds to sustained overloads, short-time protection provides controlled response to short-circuit conditions, and instantaneous protection enables rapid interruption of severe fault currents. The Rc functionality adds residual-current protection for applications requiring detection of qualifying leakage or residual-current conditions.

Combined with the T7L breaker's 120 kA ultimate breaking capacity at 400 V AC, the 1SDA062696R1 provides a comprehensive solution for high-current distribution systems requiring adjustable electronic protection, residual-current functionality and substantial fault-interruption performance.

Typical Applications

  • Industrial low-voltage power-distribution switchboards.
  • Main distribution boards and high-current feeders.
  • Three-phase commercial and infrastructure distribution systems.
  • Installations with high prospective short-circuit currents.
  • Distribution circuits requiring residual-current protection functionality.
  • Fixed MCCB installations requiring advanced electronic protection.

Technical Specifications

Series SACE Tmax T7
Product type Moulded-case circuit breaker (MCCB)
ABB order code 1SDA062696R1
Frame / performance level T7L 800
Rated uninterrupted current (Iu) 800 A
Number of poles 3P
Protection release PR332/P-LSI Rc
Release type Electronic
Protection functions Long-time, short-time, instantaneous and residual current
Overload release adjustment range 320–800 A
Short-time delayed short-circuit adjustment range 480–8000 A
Instantaneous short-circuit adjustment range 1200–12000 A
Mounting Fixed
Main-circuit terminal position Front
Main-circuit connection Bolted connection
Operating mechanism Stored energy
Rated operational voltage 690 V AC
Rated insulation voltage (Ui) 1000 V
Rated ultimate short-circuit breaking capacity (Icu) at 400 V AC, 50 Hz 120 kA
Rated ultimate short-circuit breaking capacity (Icu) at 690 V AC 50 kA
Rated short-time withstand current (Icw) 20 kA for 1 s
Degree of protection IP20
Product net weight 12.5 kg
EAN 8015644652456

Frequently Asked Questions

What is the ABB 1SDA062696R1?

The ABB 1SDA062696R1 is a SACE Tmax T7L 800 fixed three-pole moulded-case circuit breaker rated at 800 A and equipped with a PR332/P-LSI Rc electronic protection release.

What protection unit is fitted to the ABB 1SDA062696R1?

The circuit breaker is equipped with the ABB PR332/P-LSI Rc electronic release, combining long-time, short-time and instantaneous protection with residual-current functionality.

What is the breaking capacity of the ABB 1SDA062696R1?

The T7L 800 has a rated ultimate short-circuit breaking capacity of 120 kA at 400 V AC, 50 Hz.

What is the current rating of the ABB 1SDA062696R1?

The circuit breaker has a rated uninterrupted current of 800 A, with an overload-release adjustment range of 320–800 A.

What does Rc mean in PR332/P-LSI Rc?

The Rc designation identifies the residual-current protection functionality provided by this version of the PR332/P electronic release.

Is the ABB 1SDA062696R1 fixed or withdrawable?

The 1SDA062696R1 is a fixed three-pole circuit breaker with front main-circuit terminals and a stored-energy operating mechanism.

Trusted by Electrical Engineers Worldwide

ABB SACE Tmax moulded-case circuit breakers are widely specified in industrial, commercial and infrastructure power-distribution systems where dependable electronic protection, high fault-breaking performance and robust switchboard integration are essential.