ABB 1SDA062694R1 T7L 800 fixed three-pole 800 A moulded-case circuit breaker with front terminals, stored-energy operating mechanism, PR332/P LSI electronic protection and 120 kA breaking capacity at 400–415 V AC.
£7,585.01
The ABB 1SDA062694R1 is a high-performance SACE Tmax T7L 800 moulded-case circuit breaker designed for demanding low-voltage power distribution applications. Rated at 800 A, this three-pole breaker combines fixed installation, front terminals, a stored-energy operating mechanism and an advanced PR332/P LSI electronic trip unit.
The T7L performance level is engineered for electrical systems with high prospective fault currents, providing a rated ultimate short-circuit breaking capacity of 120 kA at 400–415 V AC. Its electronic protection system provides adjustable long-time overload, short-time delayed short-circuit and instantaneous short-circuit protection for coordinated distribution-system protection.
With an 800 A rated uninterrupted current, three-pole construction and fixed front-connected configuration, the 1SDA062694R1 is particularly suited to main distribution boards and industrial switchgear. The PR332/P trip unit also provides extensive adjustment capability, allowing protection characteristics to be matched closely to downstream circuits and the wider electrical installation.
The PR332/P LSI electronic trip unit allows the T7L 800 to respond to different types of overcurrent conditions according to independently defined protection characteristics. Long-time protection responds to sustained overloads, short-time protection provides delayed operation for high fault currents where selective coordination is required, and instantaneous protection provides rapid interruption of severe short circuits.
Combined with the T7L breaker's 120 kA short-circuit breaking capability at 400–415 V AC, these adjustable LSI functions make the 1SDA062694R1 well suited to high-capacity distribution networks. The fixed construction, front terminals and stored-energy mechanism provide a robust configuration for integration into industrial switchboards, main distribution assemblies and other critical low-voltage installations.
| Series | SACE Tmax T7 |
|---|---|
| ABB order code | 1SDA062694R1 |
| Product type | Moulded-case circuit breaker |
| Performance level | L |
| Rated current (In) | 800 A |
| Rated uninterrupted current (Iu) | 800 A |
| Number of poles | 3 |
| Trip unit | PR332/P LSI |
| Trip unit technology | Solid-state electronic |
| Protection functions | LSI |
| Long-time protection | L |
| Short-time delayed protection | S |
| Instantaneous protection | I |
| Overload protection setting range | 320–800 A |
| Short-time delayed short-circuit setting range | 480–8000 A |
| Instantaneous short-circuit setting range | 1200–12000 A |
| Rated operational voltage | 690 V AC |
| Rated ultimate short-circuit breaking capacity (Icu) at 400–415 V AC | 120 kA |
| Mounting type | Fixed |
| Main terminal position | Front |
| Main circuit connection | Bolted connection |
| Operating mechanism | Stored energy |
| Degree of protection | IP20 |
| Electrical durability | 2000 cycles |
| Mechanical durability | 10000 cycles |
| Product width | 210 mm |
| Product height | 268 mm |
| Product depth | 178 mm |
| Net weight | 11 kg |
| EAN | 8015644652432 |
| Customs tariff number | 85362090 |
| ABB product group | 310511-T-Max T4 - T8 |
The ABB 1SDA062694R1 is a Tmax T7L 800 three-pole moulded-case circuit breaker rated at 800 A, with fixed front terminals, a stored-energy operating mechanism and a PR332/P LSI electronic trip unit.
The circuit breaker is fitted with an ABB PR332/P LSI solid-state electronic trip unit providing long-time overload, short-time delayed short-circuit and instantaneous short-circuit protection.
The T7L 800 has a rated ultimate short-circuit breaking capacity (Icu) of 120 kA at 400–415 V AC, making it suitable for installations with high prospective fault currents.
The PR332/P LSI configuration provides an overload setting range of 320–800 A, a short-time delayed short-circuit setting range of 480–8000 A and an instantaneous short-circuit setting range of 1200–12000 A.