1SDA062683R1 ABB Tmax T7L 800 PR232/P-LSI 800A 4-Pole Fixed Circuit Breaker

1SDA062683R1 ABB Tmax T7L 800 PR232/P-LSI 800A 4-Pole Fixed Circuit Breaker

ABB 1SDA062683R1 is a Tmax T7L 800 A four-pole fixed moulded-case circuit breaker with front terminals and a PR232/P electronic trip unit providing LSI overload and short-circuit protection.

SKU: 1SDA062683R1MPN: 1SDA062683R1
Price
List Price £11,373.25 ex VAT
Your Price (ex VAT) Save 25%
£8,529.94 25% OFF
You save £2,843.31 per unit
Manufacturer Lead Time Estimated Delivery 10 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £8,529.94
Trade pricing is personalised to your account

Manufacturer Lead Time

£8,529.94

Why Choose the ABB T7L 800 PR232/P-LSI 800A 4-Pole Circuit Breaker?

The ABB 1SDA062683R1 is a Tmax T7L 800 moulded-case circuit breaker equipped with an electronic PR232/P-LSI trip unit. Rated at 800 A and configured with 4 poles, it is designed for dependable protection and switching in demanding low-voltage power-distribution systems.

The integrated PR232/P electronic trip unit provides LSI protection, combining long-time overload, short-time short-circuit and instantaneous short-circuit protection functions. This protection combination supports selective and coordinated distribution-system design while providing electronic protection for the connected circuit.

The authoritative ABB designation T7L800PR232/PLSIIn=800A4pFF specifies the T7L 800 breaker frame, 800 A rated current, PR232/P-LSI protection, four-pole configuration and fixed breaker with front terminals. It is suited to industrial switchboards, main distribution systems and other high-current low-voltage applications.

Key Advantages

  • 800 A rated current for high-current distribution applications.
  • 4-pole configuration for three-phase and neutral switching/protection arrangements.
  • Electronic PR232/P trip unit.
  • LSI protection functions for overload and short-circuit protection.
  • T7L performance version within the ABB Tmax T7 family.
  • Fixed, front-terminal configuration for switchboard installation.

Key Features

  • ABB Tmax T7L 800 moulded-case circuit breaker.
  • Rated current: 800 A.
  • Number of poles: 4.
  • Trip unit: PR232/P.
  • Protection functions: LSI.
  • L: long-time overload protection.
  • S: short-time short-circuit protection.
  • I: instantaneous short-circuit protection.
  • Installation: fixed.
  • Terminals: front.
  • ABB order code 1SDA062683R1.

PR232/P-LSI Electronic Protection

The PR232/P-LSI electronic trip unit provides multiple protection functions for low-voltage distribution circuits. Long-time protection addresses sustained overload conditions, while short-time protection provides a controlled response to higher short-circuit currents and can support coordination with downstream protective devices.

Instantaneous protection provides rapid operation for severe short-circuit conditions. Combined within the LSI configuration, these functions make the ABB T7L 800 suitable for distribution applications requiring electronic overload and short-circuit protection with greater coordination capability than a basic thermal-magnetic arrangement.

Typical Applications

  • Main low-voltage distribution switchboards.
  • Industrial power-distribution systems.
  • High-current feeder protection.
  • Commercial and infrastructure electrical distribution.
  • Four-pole three-phase distribution circuits.
  • OEM switchgear and electrical control panels.

Technical Specifications

Series Tmax T7
Order code 1SDA062683R1
Product type Moulded-case circuit breaker (MCCB)
Frame T7L 800
Rated current 800 A
Number of poles 4
Trip unit PR232/P
Protection LSI
Mounting configuration Fixed
Terminal configuration Front terminals
ABB product group 310511-T-Max T4 - T8

Frequently Asked Questions

What is the ABB 1SDA062683R1?

It is an ABB Tmax T7L 800 moulded-case circuit breaker rated at 800 A, with four poles, a PR232/P electronic trip unit and LSI protection.

What protection functions does the PR232/P trip unit provide on this breaker?

This version provides LSI protection: long-time overload protection, short-time short-circuit protection and instantaneous short-circuit protection.

What is the rated current of ABB 1SDA062683R1?

The authoritative ABB specification gives a rated current of 800 A.

How many poles does the ABB T7L 800 1SDA062683R1 have?

This circuit breaker has 4 poles, making it suitable for applications requiring switching and protection arrangements incorporating three phases and a neutral.

What mounting and terminal configuration does ABB 1SDA062683R1 use?

The FF designation specifies a fixed circuit breaker with front terminals.

Trusted ABB Circuit Protection

ABB Tmax moulded-case circuit breakers combine robust switching technology with electronic protection options for industrial, commercial and infrastructure power-distribution systems requiring dependable overload and short-circuit protection.