1SDA062678R1 ABB T7L 800 PR332/P LSI 800 A 3-Pole MCCB

1SDA062678R1 ABB T7L 800 PR332/P LSI 800 A 3-Pole MCCB

ABB 1SDA062678R1 is a SACE Tmax T7L 800 A three-pole fixed moulded case circuit breaker with front terminals, a PR332/P LSI electronic trip unit and 120 kA ultimate breaking capacity at 415 V AC.

SKU: 1SDA062678R1MPN: 1SDA062678R1
Price
List Price £9,193.89 ex VAT
Your Price (ex VAT) Save 25%
£6,895.42 25% OFF
You save £2,298.47 per unit
Manufacturer Lead Time Estimated Delivery 10 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £6,895.42
Trade pricing is personalised to your account

Manufacturer Lead Time

£6,895.42

Why Choose the ABB T7L 800 1SDA062678R1 Circuit Breaker?

The ABB 1SDA062678R1 is a high-performance SACE Tmax T7L moulded case circuit breaker (MCCB) designed for protection and control of demanding low-voltage power distribution circuits. Identified by ABB as T7L 800 PR332/P LSI In=800A 3p F F, it combines an 800 A rated current with the advanced PR332/P electronic trip unit for comprehensive overload and short-circuit protection.

The T7L version provides a high ultimate short-circuit breaking capacity of 120 kA at 415 V AC, making it suitable for industrial and commercial distribution systems where substantial prospective fault currents may occur. Its PR332/P LSI electronic trip unit provides long-time overload (L), short-time short-circuit (S) and instantaneous short-circuit (I) protection functions, enabling effective protection and selectivity within complex electrical distribution networks.

With an adjustable current range of 320–800 A, this three-pole circuit breaker can be configured to suit the requirements of the protected circuit. The fixed (F) installation and front terminal (F) configuration make the 1SDA062678R1 particularly suitable for integration into industrial switchboards, distribution panels and OEM power distribution assemblies.

Key Advantages

  • High-performance 800 A moulded case circuit breaker for power distribution.
  • 120 kA ultimate breaking capacity at 415 V AC for demanding fault levels.
  • Advanced PR332/P LSI electronic trip unit.
  • Provides long-time, short-time and instantaneous protection functions.
  • Adjustable 320–800 A current range for flexible circuit protection.
  • Three-pole fixed configuration with front terminals for switchboard installation.

Key Features

  • ABB SACE Tmax T7L 800 series.
  • 800 A rated current.
  • 320–800 A adjustable current range.
  • PR332/P LSI electronic protection trip unit.
  • Long-time overload (L) protection.
  • Short-time short-circuit (S) protection.
  • Instantaneous short-circuit (I) protection.
  • 120 kA Icu at 415 V AC.
  • Three-pole (3P) construction.
  • Fixed (F) installation with front terminals (F).

Advanced Protection for Industrial Power Distribution

Moulded case circuit breakers such as the ABB SACE Tmax T7L protect electrical distribution systems against potentially damaging overload and short-circuit currents. The 1SDA062678R1 combines an 800 A rating with an ultimate breaking capacity of 120 kA at 415 V AC, providing robust protection for installations with high prospective fault levels.

The integrated PR332/P LSI electronic trip unit provides a more comprehensive protection arrangement than an LI-only release by adding short-time protection. Its long-time, short-time and instantaneous functions enable protection settings to be coordinated with downstream and upstream devices, supporting selective operation and improved continuity within industrial power distribution networks.

Typical Applications

  • Industrial low-voltage power distribution systems.
  • Main and sub-main electrical switchboards.
  • Manufacturing and process plant distribution systems.
  • Commercial and infrastructure power distribution.
  • High-current feeder and cable protection.
  • OEM switchgear and electrical panel assemblies.

Technical Specifications

Series SACE Tmax T7
ABB order code 1SDA062678R1
Product type Moulded case circuit breaker (MCCB)
Frame / breaker size T7 800
Performance level L
Rated current 800 A
Adjustable current range 320–800 A
Ultimate short-circuit breaking capacity (Icu) 120 kA at 415 V AC
Number of poles 3
Trip unit PR332/P LSI electronic trip unit
Protection functions Long-time (L), short-time (S) and instantaneous (I)
Installation Fixed
Terminal configuration Front terminals
Application Power distribution protection and control
Product group 310511 – T-Max T4 - T8

Frequently Asked Questions

What is the ABB 1SDA062678R1 used for?

The ABB 1SDA062678R1 is an 800 A moulded case circuit breaker designed to protect and control low-voltage power distribution circuits against overload and short-circuit conditions.

What breaking capacity does the ABB T7L 800 1SDA062678R1 provide?

The T7L configuration provides an ultimate short-circuit breaking capacity of 120 kA at 415 V AC.

Which trip unit is fitted to the ABB 1SDA062678R1?

The circuit breaker is equipped with an ABB PR332/P LSI electronic trip unit, providing long-time overload, short-time short-circuit and instantaneous short-circuit protection.

What is the current range of the ABB 1SDA062678R1?

The breaker has an 800 A rated current with an adjustable current range of 320–800 A.

What does 3p F F mean on the ABB T7L 800?

The designation indicates a three-pole circuit breaker with a fixed installation and front terminals for connection within the switchboard.

Trusted ABB Power Distribution Protection

ABB SACE Tmax moulded case circuit breakers are designed for protection and control of low-voltage power distribution circuits, combining high interruption performance with advanced electronic trip technology for demanding industrial and commercial electrical installations.