1sda061841r1  t5s 600ul csa pr222ds/p-lsig 600 3 pole abb mccb

1sda061841r1 t5s 600ul csa pr222ds/p-lsig 600 3 pole abb mccb

ABB 1SDA061841R1 Tmax T5S 600 A three-pole moulded case circuit breaker with PR222DS/P-LSIG electronic trip unit, fixed mounting and front terminals for industrial power distribution.

SKU: 1SDA061841R1Alt SKU: T5S 600 UL/CSA PR222DS/P-LSIG 600 3p F FMPN: 1SDA061841R1
Price on application Contact us for pricing and availability.
Call 01708 343600

Why Choose the ABB 1SDA061841R1 Tmax T5S Moulded Case Circuit Breaker?

The ABB 1SDA061841R1 is a robust Tmax T5S moulded case circuit breaker (MCCB) designed for reliable protection in demanding industrial and commercial power distribution systems. As part of the proven ABB SACE Tmax T series, this breaker provides dependable overload, short-circuit and earth fault protection for electrical installations requiring high performance and long-term operational safety.

Equipped with a PR222DS/P-LSIG electronic trip unit, the ABB 1SDA061841R1 offers long-time, short-time, instantaneous and ground fault protection functions for accurate system coordination. Its solid-state release helps improve protection precision compared with traditional thermal magnetic devices, making it suitable for switchboards, distribution panels and industrial control systems.

With a 600 A rated current, three-pole fixed construction and front terminal connections, this MCCB is engineered for straightforward panel installation and dependable performance. Its UL/CSA configuration makes it suitable for projects requiring recognised North American compliance within industrial power distribution applications.

Key Advantages

  • High-performance 600 A moulded case circuit breaker for power distribution.
  • Advanced PR222DS/P-LSIG electronic trip unit with ground fault protection.
  • Three-pole fixed MCCB with front terminal connections.
  • Designed for demanding industrial and commercial electrical installations.
  • Suitable for switchboards, feeder protection and motor control centres.
  • Manufactured by ABB for dependable operation and long service life.

Key Features

  • ABB SACE Tmax T5S series.
  • 600 A rated current.
  • Three-pole (3P) fixed configuration.
  • PR222DS/P-LSIG solid-state electronic release.
  • Long-time, short-time, instantaneous and ground fault protection.
  • 600 V AC rated operational voltage.
  • Front terminal connection arrangement.
  • UL/CSA version for compliant installations.
  • Compact MCCB format for panel and switchboard integration.

Reliable Circuit Protection for Industrial Installations

Moulded case circuit breakers such as the ABB Tmax T5S are essential for protecting electrical circuits from overloads and short-circuit faults. By disconnecting the circuit under abnormal conditions, the breaker helps protect equipment, cabling and downstream electrical components from damage.

The PR222DS/P-LSIG release provides adjustable electronic protection functions that allow engineers to coordinate protection settings across the wider installation. This supports improved selectivity, reduced downtime and safer operation in complex power distribution networks.

Typical Applications

  • Industrial switchboards and distribution boards.
  • Main incoming and feeder protection.
  • Motor control centres.
  • Manufacturing and process facilities.
  • Commercial building power distribution.
  • OEM electrical panels and machinery systems.

Technical Specifications

Tick the specs you need, then view products that match.

Current 600 A
Phase Three Phase
Poles 3-pole
Device Type MCCB
Trip Unit Electronic
Manufacturer ABB
Series SACE Tmax T5S
Model T5S 600 UL/CSA PR222DS/P-LSIG 600 3p F F
Product ID 1SDA061841R1
Product type Moulded case circuit breaker
Rated current 600 A
Rated uninterrupted current 600 A
Rated operational voltage 600 V AC
Number of poles 3
Trip unit PR222DS/P-LSIG electronic release
Protection functions LSI + G
Connection type Front terminals
Mounting type Fixed
Rated insulation voltage 1000 V
Rated impulse withstand voltage 8 kV
Dimensions (H × W × D) approx. 205 × 140 × 103.5 mm
Weight approx. 5.1 kg

Frequently Asked Questions

What is the ABB 1SDA061841R1 used for?

The ABB 1SDA061841R1 is used to protect industrial and commercial electrical circuits against overloads, short circuits and ground fault conditions.

What current rating does this MCCB have?

This breaker has a 600 A rated current, making it suitable for high-current power distribution applications.

What type of trip unit is fitted?

It is fitted with a PR222DS/P-LSIG electronic trip unit, providing long-time, short-time, instantaneous and ground fault protection functions.

How many poles does the ABB 1SDA061841R1 have?

This model is a three-pole fixed circuit breaker.

Where is this breaker typically installed?

It is typically installed in switchboards, distribution panels, motor control centres and industrial power distribution systems.

Trusted by Electrical Engineers Worldwide

ABB Tmax moulded case circuit breakers are widely trusted by panel builders, electrical contractors and industrial engineers for dependable circuit protection, flexible coordination and long-term reliability in demanding power distribution environments.