1sda061692r1  t6s 800 ul/csa pr222ds/p-lsi 800 3 pole abb mccb

1sda061692r1 t6s 800 ul/csa pr222ds/p-lsi 800 3 pole abb mccb

ABB 1SDA061692R1 T6S 800 UL/CSA moulded case circuit breaker with PR222DS/P-LSI electronic release, 800 A rated current, three-pole fixed construction and front terminals for industrial power distribution.

SKU: 1SDA061692R1Alt SKU: T6S 800 UL/CSA PR222DS/P-LSI 800 3p F FMPN: 1SDA061692R1
Price on application Contact us for pricing and availability.
Call 01708 343600

Why Choose the ABB T6S 800 UL/CSA PR222DS/P-LSI 800 3P Fixed MCCB?

The ABB 1SDA061692R1 is a high-performance SACE Tmax T6S moulded case circuit breaker (MCCB) designed for dependable protection in industrial and commercial power distribution systems. Featuring a fixed three-pole construction, front terminal connections and an advanced PR222DS/P-LSI solid-state electronic release, it provides accurate protection against overloads and short-circuit faults.

As part of the proven ABB Tmax T series, this MCCB combines robust construction with precise electronic trip performance. The PR222DS/P-LSI release provides long-time, short-time and instantaneous protection functions, helping engineers optimise selectivity, improve coordination and reduce unnecessary downtime in critical electrical networks.

With an 800 A rated current, 800 A frame size and 600 V AC rated operational voltage, the ABB T6S is suitable for switchboards, motor control centres, industrial machinery, infrastructure systems and commercial electrical installations requiring reliable high-current circuit protection.

Key Advantages

  • High-performance ABB SACE Tmax T6S moulded case circuit breaker.
  • 800 A rated current in a robust T6 frame.
  • Advanced PR222DS/P-LSI electronic trip unit for precise protection.
  • Three-pole fixed design with front terminal connections.
  • Reliable overload and short-circuit protection for industrial systems.
  • Suitable for demanding UL/CSA electrical installations.
  • Designed for long service life and dependable operation.

Key Features

  • ABB SACE Tmax T series.
  • Product code: 1SDA061692R1.
  • T6S 800 frame size.
  • 800 A rated current.
  • PR222DS/P-LSI solid-state electronic release.
  • Three-pole configuration.
  • Fixed circuit breaker version.
  • Front terminal connection type.
  • 600 V AC rated operational voltage.
  • Robust construction for industrial power distribution and protection systems.

Reliable High-Current Circuit Protection

Moulded case circuit breakers such as the ABB Tmax T6S protect electrical installations by automatically disconnecting fault currents before they can damage equipment or disrupt operations. Its electronic trip technology enables precise adjustment of protection settings, helping improve discrimination and system reliability.

The ABB 1SDA061692R1 is well suited to installations where high current capacity, dependable interruption and robust construction are essential. Its fixed configuration and front terminal layout make it practical for integration into switchboards, control panels and OEM power distribution equipment.

Typical Applications

  • Industrial switchboards and distribution panels.
  • Main incoming and feeder circuit protection.
  • Motor control centres.
  • Manufacturing and process control systems.
  • Commercial electrical installations.
  • Infrastructure and utility power distribution.
  • OEM machinery and electrical equipment.

Technical Specifications

Tick the specs you need, then view products that match.

Current 800 A
Phase Three Phase
Poles 3-pole
Device Type MCCB
Trip Unit Electronic
Manufacturer ABB
Series SACE Tmax T
Model T6S 800 UL/CSA PR222DS/P-LSI 800 3P F F
Product ID 1SDA061692R1
EAN 8015644642310
Product type Moulded Case Circuit Breaker (MCCB)
Frame size T6 800
Rated current 800 A
Rated uninterrupted current (Iu) 800 A
Rated operational voltage 600 V AC
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 8 kV
Frequency 50 / 60 Hz
Trip unit PR222DS/P-LSI electronic release
Release type Electronic
Number of poles 3P
Mounting type Fixed
Terminal type Front terminals
Short-circuit performance level S
Standards UL / CSA
Mechanical durability 20,000 cycles
Power loss 32 W per pole at rated operating conditions
Dimensions (H × W × D) approx. 268 × 210 × 103.5 mm
Weight approx. 9.5 kg

Frequently Asked Questions

What is the ABB 1SDA061692R1 used for?

It is a moulded case circuit breaker used to protect industrial and commercial electrical distribution systems from overloads and short-circuit faults.

What trip unit does this MCCB use?

This model is fitted with the PR222DS/P-LSI electronic release, providing long-time, short-time and instantaneous protection functions.

What is the rated current of the ABB 1SDA061692R1?

The circuit breaker has an 800 A rated current and uses an 800 A T6 frame.

How many poles does this breaker have?

The ABB 1SDA061692R1 is a three-pole fixed moulded case circuit breaker.

Where is this circuit breaker typically installed?

It is commonly installed in industrial switchboards, power distribution panels, motor control centres and OEM electrical systems.

Trusted by Electrical Engineers Worldwide

ABB SACE Tmax moulded case circuit breakers are widely specified by electrical engineers and panel builders for dependable protection, precise electronic trip performance and long-term reliability in critical power distribution systems.