1sda061671r1  t6n 800 ul/csa pr222ds/p-lsig 600 4 pole abb mccb

1sda061671r1 t6n 800 ul/csa pr222ds/p-lsig 600 4 pole abb mccb

ABB 1SDA061671R1 Tmax T6N 800 UL/CSA moulded case circuit breaker with PR222DS/P-LSIG electronic trip unit, 600 A rated current, four-pole fixed construction and front terminals for low voltage power distribution.

SKU: 1SDA061671R1Alt SKU: T6N 800 UL/CSA PR222DS/P-LSIG 600 4p F FMPN: 1SDA061671R1
Price on application Contact us for pricing and availability.
Call 01708 343600

Why Choose the ABB 1SDA061671R1 Tmax T6N 800 MCCB?

The ABB 1SDA061671R1 is a high-performance Tmax T6N moulded case circuit breaker (MCCB) designed to provide dependable protection for industrial and commercial low voltage power distribution systems. As part of the proven ABB Tmax T series, this fixed four-pole circuit breaker is engineered for demanding switchboards, distribution panels and OEM electrical equipment.

This model is fitted with a PR222DS/P-LSIG solid-state electronic trip unit, providing long-time, short-time, instantaneous and ground fault protection functions. The LSIG electronic release helps improve system coordination, selective protection and fault management in applications where reliable protection and reduced downtime are essential.

With a 600 A rated current, 800 A frame size, four-pole construction and front terminal connections, the ABB 1SDA061671R1 is suitable for low voltage AC systems requiring robust circuit protection, neutral switching and UL/CSA approved performance.

Key Advantages

  • Reliable ABB Tmax T6N moulded case circuit breaker.
  • 600 A rated current within an 800 A frame size.
  • Four-pole fixed construction for three-phase systems with neutral protection.
  • PR222DS/P-LSIG electronic trip unit with ground fault protection.
  • Long-time, short-time, instantaneous and ground fault protection functions.
  • Front terminal design for straightforward switchboard installation.
  • UL and CSA approved for North American applications.

Key Features

  • ABB Tmax T Series.
  • T6N 800 frame size.
  • 600 A rated current.
  • Four-pole MCCB.
  • PR222DS/P-LSIG solid-state release.
  • Long-time, short-time, instantaneous and ground fault protection.
  • Rated operational voltage up to 600 V AC.
  • Fixed breaker with front terminal connections.

Reliable Protection for Low Voltage Power Distribution

Moulded case circuit breakers such as the ABB Tmax T6N are used to protect low voltage electrical systems from overloads, short circuits and ground faults. By disconnecting faulty circuits quickly and reliably, they help protect cables, switchgear and connected equipment while supporting safe system operation.

The PR222DS/P-LSIG electronic trip unit provides precise protection adjustment for coordinated power distribution systems. This makes the ABB 1SDA061671R1 suitable for industrial switchboards, machinery panels, commercial distribution systems and applications requiring dependable UL and CSA approved circuit protection.

Typical Applications

  • Industrial switchboards and panel boards.
  • Main low voltage distribution boards.
  • Motor control centres.
  • OEM machinery and equipment panels.
  • Generator and transformer protection.
  • Commercial building power distribution.
  • Manufacturing and process plants.
  • Export equipment requiring UL and CSA approvals.

Technical Specifications

Tick the specs you need, then view products that match.

Current 600 A
Phase Three Phase
Poles 4-pole
Device Type MCCB
Trip Unit Electronic
Manufacturer ABB
Series Tmax T
Model T6N 800 UL/CSA PR222DS/P-LSIG
SKU 1SDA061671R1
EAN 8015644642105
Product type Moulded Case Circuit Breaker (MCCB)
Frame size T6 800
Rated current 600 A
Rated uninterrupted current 800 A
Number of poles 4P
Rated operational voltage 600 V AC
Rated insulation voltage 1000 V
Rated impulse withstand voltage 8 kV
Trip unit PR222DS/P-LSIG
Release type Electronic / solid-state
Interrupting capacity 65 kA at 240 V AC, 35 kA at 480 V AC, 20 kA at 600 V AC
Terminal connection Front fixed terminals
Mounting type Fixed installation
Mechanical durability 20,000 operating cycles
Protection rating IP20
Dimensions (H × W × D) 268 × 280 × 103.5 mm
Weight approx. 9.5 kg

Frequently Asked Questions

What is the ABB 1SDA061671R1 used for?

The ABB 1SDA061671R1 is used to protect industrial and commercial low voltage electrical distribution systems against overloads, short circuits and ground faults.

What is the rated current of this MCCB?

This circuit breaker has a 600 A rated current within an 800 A frame size.

What trip unit is fitted to the ABB 1SDA061671R1?

The breaker is fitted with a PR222DS/P-LSIG solid-state electronic trip unit for long-time, short-time, instantaneous and ground fault protection.

How many poles does this circuit breaker have?

The ABB 1SDA061671R1 is a four-pole moulded case circuit breaker suitable for three-phase systems requiring neutral protection.

Is this MCCB suitable for UL and CSA applications?

Yes, this model is designed for installations requiring UL and CSA approved circuit protection.

Trusted by Electrical Engineers Worldwide

ABB Tmax moulded case circuit breakers are trusted by panel builders, contractors and electrical engineers worldwide for reliable circuit protection, flexible electronic trip technology and dependable performance in demanding low voltage power distribution systems.