1sda061667r1  t6n 800 ul/csa pr222ds/p-lsi 600 3 pole abb mccb

1sda061667r1 t6n 800 ul/csa pr222ds/p-lsi 600 3 pole abb mccb

ABB Tmax T6N 800 UL/CSA moulded case circuit breaker with PR222DS/P-LSI electronic trip unit, 600 A rated current, three-pole fixed construction and front terminals for industrial power distribution.

SKU: 1SDA061667R1Alt SKU: T6N 800 UL/CSA PR222DS/P-LSI 600 3p F FMPN: 1SDA061667R1
Price on application Contact us for pricing and availability.
Call 01708 343600

Why Choose the ABB 1SDA061667R1 Tmax T6N 800 MCCB?

The ABB 1SDA061667R1 is a premium Tmax T6N moulded case circuit breaker (MCCB) engineered to provide reliable protection for industrial and commercial low voltage power distribution systems. As part of ABB's proven Tmax T series, this fixed three-pole circuit breaker delivers dependable protection for switchboards, OEM machinery and critical electrical infrastructure.

This model is equipped with the advanced PR222DS/P-LSI solid-state electronic trip unit, providing adjustable long-time, short-time and instantaneous protection functions for accurate fault discrimination and improved system selectivity. The electronic release enables engineers to optimise protection settings for demanding industrial installations.

With a 600 A rated current, 800 A frame size, three-pole fixed construction and UL/CSA certification, the ABB 1SDA061667R1 is ideal for industrial switchboards, manufacturing facilities, infrastructure projects and export equipment requiring North American approvals.

Key Advantages

  • Heavy-duty ABB Tmax T6N moulded case circuit breaker.
  • 600 A rated current within an 800 A frame.
  • Three-pole configuration for industrial power distribution.
  • PR222DS/P-LSI electronic trip unit with adjustable protection.
  • Long-time, short-time and instantaneous protection functions.
  • UL and CSA approved for North American applications.
  • Reliable protection for demanding industrial environments.

Key Features

  • ABB Tmax T Series.
  • T6N 800 UL/CSA.
  • 600 A rated current.
  • 800 A frame size.
  • Three-pole MCCB.
  • PR222DS/P-LSI solid-state release.
  • Front terminal fixed installation.
  • Rated operational voltage up to 600 V AC.
  • Suitable for industrial switchboards and OEM equipment.

Reliable Protection for Industrial Power Distribution

The ABB Tmax T6N range has been developed to provide dependable circuit protection for demanding low voltage electrical systems. The PR222DS/P-LSI electronic trip unit offers accurate protection adjustment, helping improve system selectivity while protecting cables, switchgear and connected equipment against overloads and short-circuit faults.

Its robust construction, high interrupting performance and internationally recognised UL and CSA approvals make the ABB 1SDA061667R1 an excellent choice for industrial machinery, commercial switchboards and export equipment requiring dependable electrical protection.

Typical Applications

  • Industrial switchboards.
  • Main low voltage distribution panels.
  • Motor control centres.
  • OEM machinery.
  • Manufacturing facilities.
  • Commercial buildings.
  • Infrastructure projects.
  • Export equipment requiring UL and CSA certification.

Technical Specifications

Tick the specs you need, then view products that match.

Current 600 A
Phase Three Phase
Poles 3-pole
Device Type MCCB
Trip Unit Electronic
Manufacturer ABB
Series Tmax T
Model T6N 800 UL/CSA PR222DS/P-LSI 600 3P FF
SKU 1SDA061667R1
EAN 8015644642068
Product type Moulded Case Circuit Breaker (MCCB)
Frame size T6 800
Rated current (In) 600 A
Rated uninterrupted current (Iu) 800 A
Number of poles 3
Trip unit PR222DS/P-LSI
Release type Electronic / solid-state
Rated operational voltage 600 V AC
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 8 kV
Interrupting capacity (UL489) 65 kA at 240 V AC, 35 kA at 480 V AC, 20 kA at 600 V AC
Terminal type Front fixed terminals
Mounting type Fixed installation
Mechanical durability 20,000 operating cycles
Protection rating IP20
Dimensions (H × W × D) 268 × 210 × 103.5 mm
Weight Approx. 9.7 kg

Frequently Asked Questions

What is the ABB 1SDA061667R1 used for?

The ABB 1SDA061667R1 is used to protect industrial and commercial low voltage electrical systems against overloads and short-circuit faults.

What is the rated current of this MCCB?

This breaker has a 600 A rated current within an 800 A frame size.

What trip unit is fitted?

The breaker is equipped with a PR222DS/P-LSI solid-state electronic trip unit providing adjustable long-time, short-time and instantaneous protection.

How many poles does this circuit breaker have?

The ABB 1SDA061667R1 is a three-pole moulded case circuit breaker.

Is this breaker suitable for UL and CSA applications?

Yes. This model is manufactured for installations requiring UL and CSA approved circuit protection.

Trusted by Electrical Engineers Worldwide

ABB Tmax moulded case circuit breakers are trusted by electrical engineers, OEM manufacturers and panel builders worldwide for reliable protection, advanced electronic trip technology and dependable long-term performance in demanding industrial power distribution systems.