1sda061662r1  t6s 800 ul/csa tma 800-8000 3 pole abb mccb

1sda061662r1 t6s 800 ul/csa tma 800-8000 3 pole abb mccb

ABB 1SDA061662R1 Tmax T6S 800 UL/CSA moulded case circuit breaker, a three-pole fixed MCCB with front terminals and TMA thermomagnetic release rated 800 A for low voltage power distribution protection.

SKU: 1SDA061662R1Alt SKU: T6S 800 UL/CSA TMA 800-8000 3p F FMPN: 1SDA061662R1
Price on application Contact us for pricing and availability.
Call 01708 343600

Why Choose the ABB 1SDA061662R1 Tmax T6S 800 UL/CSA MCCB?

The ABB 1SDA061662R1 is a high-performance moulded case circuit breaker (MCCB) designed for dependable low voltage circuit protection in demanding industrial and commercial electrical installations. As part of the proven ABB SACE Tmax T range, this breaker provides robust protection against overloads and short circuits while supporting reliable operation in critical power distribution systems.

This model is a Tmax T6S 800 UL/CSA three-pole fixed circuit breaker equipped with a TMA thermomagnetic release. The adjustable thermomagnetic trip unit provides overload and instantaneous short-circuit protection, making it suitable for panel builders, switchgear manufacturers and engineers working to UL/CSA requirements.

With a rated current of 800 A, a three-pole configuration and front terminal connections, the ABB 1SDA061662R1 is suitable for low voltage distribution boards, industrial switchgear assemblies, feeder protection and high-current power distribution applications.

Key Advantages

  • High-performance ABB Tmax T6S moulded case circuit breaker.
  • UL/CSA version for installations requiring North American certification.
  • 800 A rated current for demanding low voltage distribution systems.
  • Three-pole fixed MCCB for three-phase power distribution.
  • TMA thermomagnetic release with adjustable instantaneous protection.
  • 50 kA interrupting capacity at 480 V AC for dependable fault protection.

Key Features

  • ABB SACE Tmax T series.
  • T6S 800 UL/CSA frame moulded case circuit breaker.
  • 800 A rated current.
  • 800 A rated uninterrupted current.
  • 3-pole configuration for three-phase systems.
  • TMA thermomagnetic release.
  • Fixed version with front terminals.
  • Rated operational voltage up to 600 V AC / 600 V DC.

Reliable Circuit Protection for Power Distribution

Moulded case circuit breakers such as the ABB Tmax T6S protect electrical systems by disconnecting circuits during overload and short-circuit conditions. The TMA thermomagnetic release provides dependable thermal overload protection and magnetic short-circuit tripping, helping engineers maintain safe and reliable power distribution.

The ABB 1SDA061662R1 is built for applications where high-current protection, UL/CSA compliance and dependable switching performance are essential. Its fixed construction and front terminal arrangement make it practical for integration into switchboards, distribution panels and industrial control assemblies.

Typical Applications

  • Industrial low voltage distribution boards.
  • UL/CSA switchgear and panel board assemblies.
  • Commercial electrical distribution systems.
  • Motor control centres and plant room power systems.
  • Feeder and transformer protection.
  • Manufacturing, processing and infrastructure installations.

Technical Specifications

Tick the specs you need, then view products that match.

Current 800 A
Phase Three Phase
Poles 3-pole
Device Type MCCB
Trip Unit Thermal-magnetic
Manufacturer ABB
Series SACE Tmax T
Model T6S 800 UL/CSA TMA 800-8000 3p F F
Product ID 1SDA061662R1
EAN 8015644642013
Order code T6S800TW
Product type Moulded case circuit breaker
Breaker frame T6
Rated current 800 A
Rated uninterrupted current 800 A
Number of poles 3P
Release TMA
Release type Thermomagnetic
Instantaneous trip setting 4000-8000 A
Rated operational voltage 600 V AC / 600 V DC
Rated insulation voltage 1000 V
Rated impulse withstand voltage 8 kV
Interrupting rating 100 kA at 240 V AC, 50 kA at 480 V AC, 25 kA at 600 V AC
Short-circuit performance level S
Version Fixed
Terminal connection Front terminals
Standards UL / CSA
Dimensions (H × W × D) 268 × 210 × 103.5 mm
Weight approx. 9.5 kg

Frequently Asked Questions

What is the ABB 1SDA061662R1 used for?

The ABB 1SDA061662R1 is used for overload and short-circuit protection in industrial and commercial low voltage power distribution systems.

What current rating does this MCCB have?

This ABB Tmax T6S UL/CSA moulded case circuit breaker has a rated current of 800 A.

How many poles does the ABB 1SDA061662R1 have?

The breaker has a three-pole configuration, making it suitable for three-phase electrical distribution systems.

What type of trip unit is fitted?

This model is fitted with a TMA thermomagnetic release, providing thermal overload protection and magnetic short-circuit protection.

Is the ABB 1SDA061662R1 UL/CSA certified?

Yes, this model is a UL/CSA version of the ABB Tmax T6S circuit breaker range.

Trusted by Electrical Engineers Worldwide

ABB Tmax moulded case circuit breakers are widely specified by panel builders, electrical contractors and industrial engineers for dependable circuit protection, robust construction and long-term reliability in low voltage power distribution systems.