1SDA061151R1 ABB E2H-A 1600 PR122/P-LI 1600 A 3-Pole Fixed Air Circuit Breaker

1SDA061151R1 ABB E2H-A 1600 PR122/P-LI 1600 A 3-Pole Fixed Air Circuit Breaker

ABB 1SDA061151R1 is a SACE Emax E2H-A 1600 A three-pole fixed air circuit breaker with a PR122/P-LI electronic overcurrent release providing long-time and instantaneous protection for low-voltage power distribution systems.

SKU: 1SDA061151R1MPN: 1SDA061151R1
Price
List Price £9,946.21 ex VAT
Your Price (ex VAT) Save 25%
£7,459.66 25% OFF
You save £2,486.55 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £7,459.66
Trade pricing is personalised to your account

Manufacturer Lead Time

£7,459.66

Why Choose the ABB 1SDA061151R1 E2H-A 1600 Air Circuit Breaker?

The ABB 1SDA061151R1 is a SACE Emax E2H-A air circuit breaker designed for dependable switching and protection in high-current low-voltage power distribution systems. This configuration is rated at 1600 A, features a three-pole fixed design and incorporates ABB's PR122/P-LI electronic overcurrent release.

The PR122/P-LI release provides long-time and instantaneous protection, delivering LI protection against sustained overloads and severe short-circuit conditions. This electronic protection combination helps safeguard cables, busbars and connected equipment in demanding industrial and commercial electrical distribution networks.

The 1SDA061151R1 is specified as an E2H-A 1600 three-pole fixed configuration. Its E2 frame, H-A performance version and 1600 A rating make it suitable for permanent integration into compatible SACE Emax switchboards where reliable high-current circuit protection is required.

Key Advantages

  • Genuine ABB SACE Emax E2H-A air circuit breaker.
  • 1600 A rated current for high-current low-voltage distribution applications.
  • Three-pole fixed configuration for permanent switchboard installation.
  • Advanced PR122/P-LI electronic overcurrent release.
  • LI functionality provides long-time overload and instantaneous short-circuit protection.
  • Robust E2 frame construction for demanding power distribution duties.
  • Suitable for incoming and feeder circuit protection in compatible low-voltage switchgear.

Key Features

  • ABB SACE Emax E2H-A circuit breaker.
  • 1600 A rated current.
  • Three-pole configuration.
  • Fixed installation design.
  • PR122/P-LI electronic overcurrent release.
  • Long-time (L) overload protection.
  • Instantaneous (I) short-circuit protection.
  • E2 frame construction.
  • H-A performance version within the SACE Emax family.
  • Designed for integration into compatible low-voltage switchboards.

Electronic LI Protection for High-Current Power Distribution

The ABB SACE Emax E2H-A provides switching, isolation and overcurrent protection for high-current low-voltage electrical networks. The fixed three-pole construction of the 1SDA061151R1 makes it suitable for permanent integration into compatible switchboards serving important incoming and distribution circuits.

Its PR122/P-LI electronic release provides long-time protection against sustained overload conditions together with instantaneous protection against severe short-circuit currents. This LI protection combination helps protect electrical distribution equipment while supporting dependable fault interruption in industrial, commercial and infrastructure installations.

Typical Applications

  • Industrial low-voltage power distribution switchboards.
  • Main incoming circuit protection.
  • High-current distribution feeder protection.
  • Manufacturing and process-industry electrical systems.
  • Commercial building power distribution.
  • Infrastructure electrical installations.
  • Three-phase circuits requiring electronic long-time and instantaneous protection.

Technical Specifications

Series SACE Emax
ABB order code 1SDA061151R1
Product group 310513-New Emax
Product type Air circuit breaker
Frame E2
Performance version H-A
Rated current 1600 A
Number of poles 3
Installation Fixed
Trip unit PR122/P-LI
Trip unit rated current 1600 A
Protection functions Long-time and instantaneous (LI)

Frequently Asked Questions

What is the ABB 1SDA061151R1?

The ABB 1SDA061151R1 is a SACE Emax E2H-A three-pole fixed air circuit breaker rated at 1600 A and equipped with a PR122/P-LI electronic overcurrent release.

What is the rated current of the ABB 1SDA061151R1?

The ABB 1SDA061151R1 has a rated current of 1600 A.

Which trip unit is fitted to the ABB 1SDA061151R1?

The circuit breaker is equipped with an ABB PR122/P-LI electronic overcurrent release.

What protection functions does the PR122/P-LI provide?

The PR122/P-LI provides long-time overload protection and instantaneous short-circuit protection, collectively identified as LI protection.

Is the ABB 1SDA061151R1 fixed or withdrawable?

The 1SDA061151R1 is a fixed three-pole air circuit breaker designed for permanent installation in compatible low-voltage switchgear.

How many poles does the ABB 1SDA061151R1 have?

The ABB 1SDA061151R1 has a three-pole configuration.

Where is the ABB E2H-A 1600 typically used?

The E2H-A 1600 is suited to industrial, commercial and infrastructure low-voltage power distribution systems, including main incoming and high-current feeder protection applications.

Trusted by Electrical Professionals Worldwide

ABB SACE Emax air circuit breakers are designed for demanding low-voltage power distribution applications, combining robust switching technology with electronic protection for industrial, commercial and infrastructure electrical systems.