1SDA060891R1 ABB E3V-A 3200 PR121/P-LSIG 3200 A 3P Fixed Air Circuit Breaker

1SDA060891R1 ABB E3V-A 3200 PR121/P-LSIG 3200 A 3P Fixed Air Circuit Breaker

ABB 1SDA060891R1 is a three-pole fixed SACE Emax E3V-A 3200 A air circuit breaker equipped with a PR121/P-LSIG electronic trip unit for overload, short-circuit and ground-fault protection.

SKU: 1SDA060891R1MPN: 1SDA060891R1
Price
List Price £26,977.62 ex VAT
Your Price (ex VAT) Save 25%
£20,233.22 25% OFF
You save £6,744.41 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £20,233.22
Trade pricing is personalised to your account

Manufacturer Lead Time

£20,233.22

Why Choose the ABB 1SDA060891R1 E3V-A 3200 Air Circuit Breaker?

The ABB 1SDA060891R1, manufacturer designation E3V-A 3200 PR121/P-LSIG In3200 3pF, is a high-performance SACE Emax E3V-A air circuit breaker designed for protection and switching in demanding low-voltage power distribution systems. This three-pole fixed circuit breaker combines a 3200 A rated current with ABB's PR121/P-LSIG electronic trip unit.

The PR121/P electronic trip unit provides LSIG protection functions, incorporating long-time overload, short-time short-circuit, instantaneous short-circuit and ground-fault protection. This combination provides comprehensive overcurrent and earth-fault protection for high-capacity industrial, commercial and infrastructure electrical distribution systems.

The 1SDA060891R1 combines the E3 frame with ABB's V-A performance class and a fixed three-pole construction. Its 3200 A current rating makes it particularly suitable for high-capacity switchboards, incoming supplies and main distribution circuits requiring robust air circuit-breaker technology and electronic protection.

Key Advantages

  • Genuine ABB SACE Emax E3V-A air circuit breaker.
  • 3200 A rated current for high-capacity low-voltage distribution systems.
  • Equipped with a PR121/P-LSIG electronic trip unit.
  • E3V-A performance class for demanding power distribution applications.
  • Three-pole fixed configuration for permanent switchboard installation.
  • LSIG functionality provides overload, short-circuit and ground-fault protection.

Key Features

  • ABB SACE Emax E3V-A series.
  • 3200 A rated current.
  • PR121/P electronic trip unit.
  • LSIG protection functions.
  • Three-pole configuration.
  • Fixed (F) circuit-breaker execution.
  • Electronic overcurrent and ground-fault protection for high-current low-voltage networks.
  • Designed for demanding industrial, commercial and infrastructure power distribution.

Comprehensive LSIG Protection for High-Current Distribution

The ABB PR121/P electronic trip unit provides comprehensive protection for low-voltage electrical networks. Its LSIG configuration combines long-time protection against sustained overloads, short-time protection for short-circuit conditions, instantaneous protection for rapid interruption of severe faults and ground-fault protection for earth-fault conditions.

Combined with the E3V-A breaker platform, the PR121/P release makes the 1SDA060891R1 suitable for high-capacity distribution systems where dependable switching and electronic fault protection are required. Its fixed execution is intended for permanent integration into a compatible switchboard, providing a robust solution for main incomers, distribution circuits and high-current feeder applications.

Typical Applications

  • High-current industrial low-voltage switchboards.
  • Main incoming circuit-breaker applications.
  • Main electrical distribution panels.
  • Manufacturing and process facilities.
  • Commercial and infrastructure power distribution.
  • High-capacity feeder protection.
  • Fixed ABB SACE Emax circuit-breaker installations.

Technical Specifications

Series SACE Emax
Order code / MPN 1SDA060891R1
Product group 310513-New Emax
Product type Air circuit breaker
Breaker type E3V-A
Frame E3
Performance class V-A
Rated current (In) 3200 A
Number of poles 3P
Execution Fixed (F)
Trip unit PR121/P
Protection functions LSIG
Long-time protection (L) Overload protection
Short-time protection (S) Short-circuit protection with time delay
Instantaneous protection (I) Instantaneous short-circuit protection
Ground-fault protection (G) Earth / ground-fault protection
Application Low-voltage power distribution and circuit protection

Frequently Asked Questions

What is the ABB 1SDA060891R1 used for?

The ABB 1SDA060891R1 is a three-pole fixed SACE Emax E3V-A air circuit breaker designed for switching and protecting high-current low-voltage electrical distribution systems.

What is the rated current of the ABB 1SDA060891R1?

The E3V-A circuit breaker has a rated current of 3200 A.

What protection functions does the PR121/P trip unit provide?

The fitted PR121/P-LSIG electronic trip unit provides long-time overload, short-time short-circuit, instantaneous short-circuit and ground-fault protection.

Is the ABB 1SDA060891R1 fixed or withdrawable?

The 1SDA060891R1 is a fixed three-pole air circuit breaker intended for permanent installation within a compatible low-voltage switchboard.

What does LSIG mean on the ABB 1SDA060891R1?

LSIG denotes long-time, short-time, instantaneous and ground-fault protection functions provided by the PR121/P electronic trip unit.

Trusted ABB Power Distribution Technology

ABB SACE Emax air circuit breakers combine high-current switching capability with electronic protection, providing dependable circuit protection for demanding industrial, commercial and infrastructure low-voltage distribution systems.