1SDA060849R1 ABB E3H-A 3200 PR123/P-LSIG 3200A 3-Pole Withdrawable Moving Part

1SDA060849R1 ABB E3H-A 3200 PR123/P-LSIG 3200A 3-Pole Withdrawable Moving Part

ABB 1SDA060849R1 is an E3H-A 3200 three-pole SACE Emax withdrawable circuit-breaker moving part rated at 3200 A with an R3200 PR123/P-LSIG electronic overcurrent release.

SKU: 1SDA060849R1MPN: 1SDA060849R1
Price
List Price £38,763.65 ex VAT
Your Price (ex VAT) Save 25%
£29,072.74 25% OFF
You save £9,690.91 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £29,072.74
Trade pricing is personalised to your account

Manufacturer Lead Time

£29,072.74

Why Choose the ABB 1SDA060849R1 E3H-A 3200 PR123/P-LSIG Moving Part?

The ABB 1SDA060849R1, identified as E3H-A 3200 PR123/P-LSIG In=3200A 3p W MP, is a three-pole moving part for a withdrawable SACE Emax E3H-A air circuit breaker. Designed for demanding low-voltage power-distribution systems, it combines a substantial 3200 A rated current with ABB’s advanced PR123/P electronic overcurrent release.

The fitted PR123/P-LSIG electronic trip unit uses an R3200 rating plug and provides long-time, short-time, instantaneous and ground-fault protection. This comprehensive LSIG arrangement supports selective protection against overloads, short circuits and ground faults in critical industrial and commercial distribution systems.

As a withdrawable moving part, the 1SDA060849R1 is designed to interface with a compatible SACE Emax E3 fixed part. The withdrawable architecture allows the breaker moving section to be removed for isolation, inspection, maintenance or replacement while the fixed switchboard connections remain installed.

Key Advantages

  • Genuine ABB SACE Emax E3H-A moving part for withdrawable circuit-breaker installations.
  • 3200 A rated current for high-current low-voltage distribution.
  • Advanced PR123/P-LSIG electronic overcurrent release.
  • Provides long-time, short-time, instantaneous and ground-fault protection.
  • R3200 rating plug matched to the breaker’s rated current.
  • 48,000 A Im value for the E3H-A 3200 configuration.
  • Three-pole UL configuration for compatible power-distribution systems.
  • Withdrawable construction supports efficient isolation, inspection and maintenance.
  • Fitted with 4 auxiliary contacts and circuit-breaker open/closed position indication.

Key Features

  • ABB SACE Emax series.
  • E3H-A 3200 frame.
  • 3200 A rated current (In).
  • R3200 rating plug.
  • PR123/P electronic trip unit.
  • LSIG protection functions.
  • Long-time overload protection (L).
  • Short-time short-circuit protection (S).
  • Instantaneous short-circuit protection (I).
  • Ground-fault protection (G).
  • 3-pole configuration.
  • Withdrawable moving-part (W MP) execution.
  • UL configuration.
  • 4 auxiliary contacts.
  • Circuit-breaker open/closed position indication.

Advanced LSIG Protection in Withdrawable Emax Switchgear

The ABB SACE Emax withdrawable architecture separates the removable circuit-breaker moving part from the fixed section installed in the switchboard. The 1SDA060849R1 can therefore be withdrawn from its compatible E3 fixed part for isolation, inspection, servicing or replacement without dismantling the principal fixed switchboard connections.

Its PR123/P-LSIG electronic release provides comprehensive protection: long-time protection responds to sustained overloads, short-time protection supports coordinated response to short circuits, instantaneous protection provides rapid interruption of severe faults, and ground-fault protection addresses unintended current paths to earth. Combined with the 3200 A E3H-A platform, this provides a robust and service-friendly solution for critical high-current distribution systems.

Typical Applications

  • Industrial low-voltage main distribution switchboards.
  • ABB SACE Emax E3H-A withdrawable circuit-breaker installations.
  • High-current main incoming circuit protection.
  • High-capacity feeder protection.
  • Manufacturing and process-industry switchgear.
  • Commercial and infrastructure power-distribution systems.
  • Distribution systems requiring ground-fault protection.
  • UL switchboards requiring 3200 A LSIG electronic protection.

Technical Specifications

Series SACE Emax
Model / type E3H-A 3200 PR123/P-LSIG
ABB order code 1SDA060849R1
Product group New Emax
Product type Air circuit-breaker moving part
Frame E3H-A 3200
Performance class H
Rated current (In) 3200 A
Rating plug R3200
Number of poles 3
Execution Withdrawable moving part (W MP)
Trip unit PR123/P
Protection functions LSIG
Long-time protection L
Short-time protection S
Instantaneous protection I
Ground-fault protection G
Im 48,000 A
Auxiliary contacts 4
Breaker position indication Open / closed
Product configuration UL
Product net weight 64 kg
EAN 8015644633721
HS code 85362090

Frequently Asked Questions

What is the ABB 1SDA060849R1?

The ABB 1SDA060849R1 is a 3200 A three-pole moving part for a withdrawable SACE Emax E3H-A air circuit breaker, equipped with a PR123/P-LSIG electronic overcurrent release.

What protection functions does the PR123/P-LSIG trip unit provide?

The LSIG configuration provides long-time overload, short-time short-circuit, instantaneous short-circuit and ground-fault protection.

What is the rated current of the ABB 1SDA060849R1?

The ABB 1SDA060849R1 has a rated current of 3200 A and uses an R3200 rating plug.

Is the ABB 1SDA060849R1 fixed or withdrawable?

The 1SDA060849R1 is a withdrawable moving part (W MP) designed to interface with a compatible ABB SACE Emax E3 fixed part installed in the switchboard.

Does the ABB 1SDA060849R1 include auxiliary contacts?

Yes. This configuration is fitted with 4 auxiliary contacts and provides circuit-breaker open/closed position indication.

Trusted ABB SACE Emax Circuit Protection

ABB SACE Emax withdrawable air circuit breakers combine high-current capability, advanced electronic protection and service-friendly construction, supporting dependable overload, short-circuit and ground-fault protection in demanding low-voltage power-distribution systems.