1SDA060589R1 ABB T6L 1000 Breaking Part 3-Pole Fixed Front Terminals

1SDA060589R1 ABB T6L 1000 Breaking Part 3-Pole Fixed Front Terminals

ABB 1SDA060589R1 is a 1000 A three-pole fixed SACE Tmax T6L 1000 circuit breaker breaking unit with front terminals and 100 kA ultimate short-circuit breaking capacity at 400–415 V AC.

SKU: 1SDA060589R1MPN: 1SDA060589R1
Price
List Price £8,452.76 ex VAT
Your Price (ex VAT) Save 25%
£6,339.57 25% OFF
You save £2,113.19 per unit
Manufacturer Lead Time Estimated Delivery 10 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £6,339.57
Trade pricing is personalised to your account

Manufacturer Lead Time

£6,339.57

Why Choose the ABB 1SDA060589R1 T6L 1000 Breaking Part?

The ABB 1SDA060589R1 is a high-performance circuit breaker breaking unit designed for the ABB SACE Tmax T6L 1000 moulded-case circuit-breaker system. Identified as T6L 1000 BREAKING PART 3p F F, this unit features a fixed three-pole configuration with front terminals and is intended for assembly with a compatible T6 protection trip unit.

As part of the ABB SACE Tmax T6 series, the T6L breaking part provides the main switching and interruption mechanism of the circuit breaker. It has a rated uninterrupted current of 1000 A and the T6L performance level provides a rated ultimate short-circuit breaking capacity of 100 kA at 400–415 V AC, making it suitable for demanding low-voltage distribution systems with high prospective fault currents.

The 1SDA060589R1 is supplied as a three-pole fixed breaking unit with front terminals rather than a complete circuit breaker with a protection release. This modular arrangement allows a compatible ABB T6 1000 trip unit to be selected according to the required protection functions while retaining the robust T6L breaking performance.

Key Advantages

  • Genuine ABB SACE Tmax T6L circuit breaker breaking unit.
  • 1000 A rated uninterrupted current for high-current distribution applications.
  • 100 kA ultimate breaking capacity at 400–415 V AC.
  • Three-pole fixed configuration for professional switchboard installations.
  • Front terminals provide straightforward main-circuit connections.
  • Modular design allows installation with a compatible ABB T6 1000 protection trip unit.

Key Features

  • ABB SACE Tmax T6 series.
  • T6L 1000 breaking part.
  • 1000 A rated uninterrupted current (Iu).
  • 100 kA Icu at 400–415 V AC.
  • Three-pole configuration.
  • Fixed installation.
  • Front main-circuit terminals.
  • Bolt-connected main electrical circuit.
  • 690 V AC rated operational voltage.
  • IP20 degree of protection.
  • Designed for use with a separately selected compatible protection unit.
  • ABB order code 1SDA060589R1.

High-Performance Breaking for Low-Voltage Distribution

A circuit breaker breaking unit contains the principal current-carrying, switching and interruption components required to disconnect a circuit during normal switching or fault conditions. When combined with the appropriate protection release, the assembly provides coordinated protection against electrical faults while allowing the protection characteristics to be selected for the installation.

The ABB T6L 1000 breaking unit is engineered for demanding distribution systems where high interruption performance is required. Its 1000 A current rating and 100 kA T6L breaking performance at 400–415 V AC make it particularly suitable for industrial switchboards and distribution assemblies located close to high-capacity power sources.

Typical Applications

  • Industrial low-voltage switchboards.
  • Main power distribution panels.
  • High-current feeder circuit-breaker assemblies.
  • Manufacturing and process-industry electrical systems.
  • Commercial and infrastructure power distribution.
  • ABB Tmax T6 1000 modular circuit-breaker assemblies.

Technical Specifications

Series SACE Tmax T6
Order code 1SDA060589R1
Product type Circuit breaker breaking unit
Breaker frame T6L 1000
Rated uninterrupted current (Iu) 1000 A
Rated operational voltage 690 V AC
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 8 kV
Ultimate short-circuit breaking capacity (Icu) at 400–415 V AC 100 kA
Number of poles 3
Installation Fixed
Terminal position Front
Main circuit connection Bolt connection
Protection unit Separate compatible trip unit required
Control element Toggle
Protection rating IP20
Mechanical durability 20,000 cycles
Electrical durability 4,000 cycles
Dimensions (H × W × D) approx. 215 × 210 × 103.5 mm
Net weight approx. 8.2 kg
EAN 8015644630874
Standard IEC 60947
ABB product group 310511-T-Max T4 - T8

Frequently Asked Questions

What is the ABB 1SDA060589R1 used for?

The ABB 1SDA060589R1 is the breaking unit for an ABB SACE Tmax T6L 1000 circuit breaker, providing the main switching and fault-current interruption mechanism for a compatible modular circuit-breaker assembly.

What is the rated current of the ABB 1SDA060589R1?

The T6L 1000 breaking unit has a rated uninterrupted current of 1000 A.

What is the breaking capacity of the T6L 1000?

The T6L performance level provides a rated ultimate short-circuit breaking capacity of 100 kA at 400–415 V AC.

Does the ABB 1SDA060589R1 include a protection trip unit?

No. The 1SDA060589R1 is a breaking part intended to be combined with a separately selected compatible ABB T6 1000 protection trip unit to form the required circuit-breaker configuration.

What configuration does the ABB 1SDA060589R1 use?

The unit has a three-pole fixed configuration with front terminals for installation in compatible low-voltage switchboards and distribution assemblies.