1sda060456r1  t5h 400ul csapr222ds/p-lsi in=400 4 pole abb mccb

1sda060456r1 t5h 400ul csapr222ds/p-lsi in=400 4 pole abb mccb

ABB 1SDA060456R1 SACE Tmax T5H 400 UL/CSA moulded case circuit breaker with PR222DS/P-LSI electronic trip unit, 400 A, 600 V AC, four-pole fixed design for industrial power distribution.

SKU: 1SDA060456R1Alt SKU: T5H 400 UL/CSA PR222DS/P-LSI 400 4p F FMPN: 1SDA060456R1
Price on application Contact us for pricing and availability.
Call 01708 343600

Why Choose the ABB 1SDA060456R1 Tmax T5H Moulded Case Circuit Breaker?

The ABB 1SDA060456R1 is a high performance SACE Tmax T5H moulded case circuit breaker (MCCB) designed to provide dependable protection for low voltage electrical distribution systems. As part of the ABB Tmax T range, it delivers reliable overload and short-circuit protection for demanding industrial and commercial installations where safety, continuity and high breaking performance are essential.

This breaker is supplied as a T5H 400 UL/CSA fixed four-pole circuit breaker with front terminals and an advanced PR222DS/P-LSI electronic trip unit. The adjustable electronic release provides long-time, short-time and instantaneous protection functions, helping engineers achieve accurate protection coordination across switchboards and power distribution systems.

With a 400 A rated current, 400 A frame size and a 600 V AC rated operational voltage, the ABB 1SDA060456R1 is suitable for industrial control panels, motor control centres, feeder protection and commercial power distribution systems requiring robust four-pole circuit protection.

Key Advantages

  • High performance ABB SACE Tmax T5H moulded case circuit breaker.
  • 400 A rated current with 400 A frame size.
  • PR222DS/P-LSI electronic trip unit with adjustable protection functions.
  • Four-pole fixed design with front terminal connections.
  • 600 V AC rated operational voltage for UL/CSA installations.
  • Reliable protection for feeders, switchboards and OEM electrical panels.

Key Features

  • ABB SACE Tmax T series.
  • T5H 400 UL/CSA moulded case circuit breaker.
  • 400 A rated current.
  • Four-pole configuration.
  • PR222DS/P-LSI electronic release.
  • Fixed circuit breaker construction.
  • Front terminal connection.
  • High short-circuit performance level.
  • Designed for low voltage AC applications.

Reliable Protection for Industrial Power Distribution

Moulded case circuit breakers such as the ABB Tmax T5H help protect electrical circuits by disconnecting the supply during overload or short-circuit fault conditions. This supports equipment protection, reduces downtime and improves safety across low voltage power distribution networks.

The PR222DS/P-LSI electronic trip unit allows engineers to configure protection settings to suit the installation, making the breaker suitable for switchboards, OEM machinery and distribution systems requiring dependable four-pole protection and operational flexibility.

Typical Applications

  • Industrial power distribution systems.
  • Main and feeder circuit protection.
  • Switchboards and distribution panels.
  • Four-pole circuit isolation applications.
  • Motor control centres.
  • OEM electrical assemblies.
  • Commercial building infrastructure.

Technical Specifications

Tick the specs you need, then view products that match.

Current 400 A
Phase Three Phase
Poles 4-pole
Device Type MCCB
Trip Unit Electronic
Manufacturer ABB
Series SACE Tmax T
Model T5H 400 UL/CSA PR222DS/P-LSI 400 4P F F
Part number 1SDA060456R1
EAN 8015644629441
Product type Moulded Case Circuit Breaker (MCCB)
Rated current 400 A
Rated uninterrupted current 400 A
Rated operational voltage 600 V AC
Rated insulation voltage 1000 V
Rated impulse withstand voltage 8 kV
Number of poles 4P
Trip unit PR222DS/P-LSI
Release type Electronic
Terminal connection type Front terminals
Mounting type Fixed
Short-circuit performance level H
Standards UL / CSA
Mechanical durability 20,000 cycles
Dimensions (H × W × D) approx. 205 × 186 × 103.5 mm
Weight approx. 6.2 kg

Frequently Asked Questions

What is the ABB 1SDA060456R1 used for?

The ABB 1SDA060456R1 protects low voltage electrical distribution systems against overloads and short circuits in industrial and commercial installations.

What is the rated current of this circuit breaker?

This moulded case circuit breaker has a 400 A rated current with a 400 A frame size.

Which trip unit is fitted?

The breaker is equipped with a PR222DS/P-LSI electronic trip unit providing adjustable long-time, short-time and instantaneous protection.

How many poles does this MCCB have?

The ABB 1SDA060456R1 is supplied as a four-pole fixed circuit breaker.

Where is this breaker typically installed?

It is commonly installed within switchboards, distribution panels, motor control centres and OEM electrical equipment.

Trusted by Electrical Engineers Worldwide

ABB SACE Tmax moulded case circuit breakers are trusted worldwide for dependable circuit protection, advanced electronic trip technology and reliable performance across demanding industrial and commercial electrical installations.