1SDA060300R1 ABB T6L 800 PR221DS-I 800 A 3P Fixed Moulded-Case Circuit Breaker

1SDA060300R1 ABB T6L 800 PR221DS-I 800 A 3P Fixed Moulded-Case Circuit Breaker

ABB 1SDA060300R1 is an 800 A three-pole fixed Tmax T6L moulded-case circuit breaker with front terminals, a PR221DS-I electronic trip unit and high short-circuit performance for low-voltage power distribution.

SKU: 1SDA060300R1MPN: 1SDA060300R1
Price
List Price £6,792.16 ex VAT
Your Price (ex VAT) Save 25%
£5,094.12 25% OFF
You save £1,698.04 per unit
Manufacturer Lead Time Estimated Delivery 10 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £5,094.12
Trade pricing is personalised to your account

Manufacturer Lead Time

£5,094.12

Why Choose the ABB T6L 800 1SDA060300R1 Moulded-Case Circuit Breaker?

The ABB 1SDA060300R1 is a high-performance Tmax T6L 800 three-pole moulded-case circuit breaker (MCCB) designed for protection of demanding low-voltage industrial and commercial power distribution systems. As part of the ABB Tmax T4–T8 range, it combines an 800 A rated current with a PR221DS-I electronic trip unit and the high short-circuit performance associated with the T6L breaker platform.

The breaker incorporates an ABB PR221DS-I solid-state electronic release for current-based circuit protection. Electronic trip technology provides accurate and repeatable protection characteristics, making the T6L 800 suitable for high-current feeders and distribution circuits where dependable operation under fault conditions is essential.

The 1SDA060300R1 is supplied as a fixed, three-pole circuit breaker with front terminals. The T6L performance level provides a rated ultimate short-circuit breaking capacity of 100 kA at 415 V AC, making this breaker particularly suitable for switchboards and industrial distribution systems with high prospective short-circuit currents.

Key Advantages

  • High-performance ABB Tmax T6L 800 moulded-case circuit breaker.
  • 800 A rated current for high-current power distribution applications.
  • Electronic PR221DS-I solid-state trip unit for dependable circuit protection.
  • High 100 kA ultimate short-circuit breaking capacity at 415 V AC.
  • Three-pole configuration for three-phase electrical distribution systems.
  • Fixed execution with front terminals for straightforward switchboard integration.

Key Features

  • ABB Tmax T6L 800 circuit-breaker platform.
  • PR221DS-I electronic trip unit.
  • 800 A rated current.
  • Three-pole (3P) construction.
  • Fixed execution.
  • Front terminals for main circuit connections.
  • High-performance L breaking-capacity level.
  • Designed for industrial and commercial low-voltage distribution systems.

High-Performance Electronic Protection for Power Distribution

Electronic moulded-case circuit breakers monitor electrical current and initiate tripping when the applicable protection threshold is reached. The PR221DS-I electronic release provides dependable current-based protection while avoiding the operating variability associated with purely thermal protection elements, supporting effective protection of high-current distribution circuits.

The ABB T6L platform is engineered for installations where substantial prospective fault currents may be present. With an 800 A rating and an ultimate short-circuit breaking capacity of 100 kA at 415 V AC, the 1SDA060300R1 provides robust protection for industrial switchboards, high-current feeders and commercial power distribution equipment.

Typical Applications

  • Industrial low-voltage power distribution systems.
  • Main and sub-main feeder protection.
  • High-fault-level switchboards and distribution panels.
  • Manufacturing and industrial production facilities.
  • Commercial and infrastructure power distribution.
  • Three-phase circuits requiring high-current electronic circuit protection.

Technical Specifications

Series Tmax T4–T8
Order code 1SDA060300R1
Product type Moulded-case circuit breaker (MCCB)
Frame T6
Performance level L
Rated current (In) 800 A
Trip unit PR221DS-I electronic / solid-state release
Number of poles 3
Execution Fixed
Terminal connection Front
Rated operational voltage up to 690 V AC
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 8 kV
Rated ultimate short-circuit breaking capacity (Icu) at 415 V AC 100 kA
Product range SACE Tmax T
ABB product group 310511-T-Max T4 - T8

Frequently Asked Questions

What is the ABB 1SDA060300R1 used for?

The ABB 1SDA060300R1 is a Tmax T6L 800 three-pole moulded-case circuit breaker designed to protect high-current low-voltage distribution circuits using a PR221DS-I electronic trip unit.

What is the current rating of the ABB 1SDA060300R1?

The breaker has a rated current of 800 A and is based on the ABB Tmax T6 800 frame.

What trip unit is fitted to the ABB 1SDA060300R1?

The breaker is fitted with an ABB PR221DS-I electronic solid-state trip unit for current-based circuit protection.

What is the breaking capacity of the ABB 1SDA060300R1?

The T6L 800 performance level provides a rated ultimate short-circuit breaking capacity of 100 kA at 415 V AC.

What does 3P F F mean on the ABB T6L 800?

The designation identifies a three-pole circuit breaker in fixed execution with front terminals, designed for permanent installation in compatible low-voltage switchboards and distribution assemblies.

Trusted ABB Circuit Protection

ABB Tmax moulded-case circuit breakers provide dependable protection for demanding industrial and commercial low-voltage power distribution systems, combining robust breaker construction, electronic protection technology and high short-circuit performance.