1SDA060265R1 ABB T6L630PR222DS/P-LSIG In=630 4p F Moulded Case Circuit Breaker

1SDA060265R1 ABB T6L630PR222DS/P-LSIG In=630 4p F Moulded Case Circuit Breaker

ABB T6L630PR222DS/P-LSIG moulded case circuit breaker with 630 A rating and LSIG electronic protection for industrial low-voltage distribution systems.

SKU: 1SDA060265R1MPN: 1SDA060265R1
Price
List Price £8,375.08 ex VAT
Your Price (ex VAT) Save 25%
£6,281.31 25% OFF
You save £2,093.77 per unit
Manufacturer Lead Time Estimated Delivery 10 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £6,281.31
Trade pricing is personalised to your account

Manufacturer Lead Time

£6,281.31

Why Choose the ABB T6L630PR222DS/P-LSIG In=630 4p F Moulded Case Circuit Breaker?

The ABB T6L630PR222DS/P-LSIG In=630 4p F is an advanced moulded case circuit breaker (MCCB) designed for high-performance protection and switching in industrial low-voltage electrical distribution systems. As part of the reliable ABB Tmax T6 series, it combines electronic trip technology with robust mechanical construction for demanding power applications.

This circuit breaker is equipped with the PR222DS/P-LSIG electronic trip unit, providing comprehensive protection functions including long-time, short-time, instantaneous and ground fault protection. The advanced trip system enables accurate protection coordination and improved monitoring of electrical networks.

With a rated current of 630 A, a four-pole configuration and a fixed terminal arrangement, the T6L630PR222DS/P-LSIG is suitable for industrial distribution systems requiring enhanced protection flexibility and dependable circuit interruption performance.

Key Advantages

  • Reliable ABB Tmax T6 moulded case circuit breaker technology.
  • 630 A rated current for industrial power distribution applications.
  • PR222DS/P-LSIG electronic trip unit provides advanced protection functions.
  • Integrated long-time, short-time, instantaneous and ground fault protection.
  • Four-pole (4P) configuration suitable for systems requiring neutral protection.
  • Supports accurate protection coordination in complex electrical installations.

Key Features

  • ABB Tmax T6L series MCCB.
  • 630 A rated current.
  • PR222DS/P-LSIG electronic trip unit.
  • LSIG protection functions: long-time, short-time, instantaneous and ground fault.
  • Four-pole (4P) circuit breaker configuration.
  • Fixed front connection terminals.
  • Electronic current measurement and protection technology.
  • Designed for industrial low-voltage distribution systems.

Reliable Protection for Industrial Electrical Systems

Electronic trip units such as the ABB PR222DS/P-LSIG improve electrical system safety by continuously monitoring current conditions and responding accurately to overloads, short circuits and earth fault conditions. This helps protect cables, equipment and connected loads while supporting selective coordination.

The ABB Tmax T6 range is engineered for modern industrial installations requiring advanced protection, compact construction and flexible configuration. The combination of electronic protection and robust MCCB design makes it suitable for demanding power distribution environments.

Typical Applications

  • Industrial switchboards and distribution panels.
  • Manufacturing plant electrical networks.
  • Motor and machinery protection systems.
  • Commercial low-voltage distribution equipment.
  • Power feeder protection assemblies.
  • Industrial automation electrical infrastructure.

Technical Specifications

Series Tmax T6
ABB order code 1SDA060265R1
Product type Moulded case circuit breaker (MCCB)
Product family 310511-T-Max T4 - T8
Rated current (In) 630 A
Number of poles 4P
Trip unit PR222DS/P-LSIG electronic trip unit
Protection functions Long-time, short-time, instantaneous and ground fault protection
Connection type Fixed front terminals
Application Low-voltage industrial power distribution
Standards IEC low-voltage circuit breaker standards

Frequently Asked Questions

What is the ABB T6L630PR222DS/P-LSIG used for?

The ABB T6L630PR222DS/P-LSIG is a moulded case circuit breaker designed to protect industrial electrical systems against overloads, short circuits and ground faults.

What type of trip unit does this ABB MCCB have?

The circuit breaker uses a PR222DS/P-LSIG electronic trip unit with long-time, short-time, instantaneous and ground fault protection functions.

What is the rated current of the ABB T6L630PR222DS/P-LSIG?

The circuit breaker has a rated current of 630 A.

How many poles does this ABB circuit breaker have?

The T6L630PR222DS/P-LSIG is a four-pole (4P) moulded case circuit breaker.

What is the ABB order code for this circuit breaker?

The ABB order code is 1SDA060265R1.

Trusted by Industrial Power Engineers Worldwide

ABB Tmax moulded case circuit breakers deliver reliable protection, advanced monitoring capability and flexible configuration for modern industrial electrical distribution systems.