1sda060226r1  t6n 630 pr221ds-ls/i in=630 3 pole abb mccb

1sda060226r1 t6n 630 pr221ds-ls/i in=630 3 pole abb mccb

ABB 1SDA060226R1 Tmax T6N three-pole moulded case circuit breaker with 630 A rated current, PR221DS-LS/I electronic release and front terminals for industrial power distribution.

SKU: 1SDA060226R1Alt SKU: T6N 630 PR221DS-LS/I In=630 3p F FMPN: 1SDA060226R1
Price
List Price £3,589.06 ex VAT
Your Price (ex VAT) Save 25%
£2,691.80 25% OFF
You save £897.27 per unit
Manufacturer Lead Time Estimated Delivery 10 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £2,691.80
Trade pricing is personalised to your account

Manufacturer Lead Time

£2,691.80

Why Choose the ABB 1SDA060226R1 Tmax T6N Moulded Case Circuit Breaker?

The ABB 1SDA060226R1 is a high-performance Tmax T6N moulded case circuit breaker (MCCB) engineered to provide reliable protection for industrial and commercial electrical distribution systems. As part of the proven ABB SACE Tmax T series, this breaker delivers advanced electronic protection against overloads and short-circuit faults while maintaining excellent reliability in demanding environments.

This three-pole fixed circuit breaker features front terminals and an advanced PR221DS-LS/I electronic trip unit, providing long-time, short-time and instantaneous protection. The electronic release offers improved protection accuracy and coordination compared with conventional thermomagnetic breakers, making it ideal for modern power distribution systems.

With a 630 A rated current, 690 V AC rated operational voltage and a rated ultimate breaking capacity of 36 kA at 415 V AC, the ABB 1SDA060226R1 is suitable for switchboards, feeder circuits, industrial control panels and OEM electrical equipment requiring dependable protection and long service life.

Key Advantages

  • High-performance ABB Tmax T6N moulded case circuit breaker.
  • 630 A rated current for industrial power distribution.
  • Three-pole fixed configuration with front terminals.
  • Advanced PR221DS-LS/I electronic release.
  • Long-time, short-time and instantaneous protection functions.
  • 690 V AC rated operational voltage.
  • Suitable for switchboards, feeder circuits and OEM electrical assemblies.

Key Features

  • ABB SACE Tmax T series.
  • T6N 630 moulded case circuit breaker.
  • 630 A rated current.
  • Three-pole fixed breaker.
  • Front terminal connection type.
  • PR221DS-LS/I solid-state electronic release.
  • High short-circuit performance level N.
  • Designed for IEC power distribution applications.

Advanced Electronic Protection for Power Distribution

The ABB PR221DS-LS/I electronic trip unit delivers accurate overload and fault protection while improving discrimination between protective devices. This helps reduce unnecessary outages and improves system reliability in industrial electrical installations.

The Tmax T6N platform is designed for demanding applications requiring dependable interruption capability, compact installation and advanced protection technology. Its robust construction makes it suitable for long-term use in industrial switchgear and power distribution equipment.

Typical Applications

  • Industrial switchboards.
  • Commercial power distribution systems.
  • Feeder circuit protection.
  • OEM electrical equipment.
  • Motor control centres.
  • Manufacturing and process plants.

Technical Specifications

Tick the specs you need, then view products that match.

Current 630 A
Phase Three Phase
Poles 3-pole
Device Type MCCB
Breaking Capacity 36 kA
Trip Unit Electronic
Manufacturer ABB
Series SACE Tmax T
Model T6N 630 PR221DS-LS/I In=630 3p F F
Product ID 1SDA060226R1
Product type Moulded Case Circuit Breaker
Rated current 630 A
Number of poles 3
Release type PR221DS-LS/I electronic release
Protection functions Long-time, short-time and instantaneous
Rated operational voltage 690 V AC
Rated insulation voltage 1000 V
Rated impulse withstand voltage 8 kV
Rated ultimate short-circuit breaking capacity 36 kA at 415 V AC
Short-circuit performance level N
Terminal connection Front terminals
Mounting type Fixed
Mechanical durability 20,000 cycles
Electrical durability 5,000 cycles
Protection rating IP20
Dimensions (H × W × D) approx. 268 × 210 × 103.5 mm
Weight approx. 9.7 kg

Frequently Asked Questions

What is the ABB 1SDA060226R1 used for?

It is used to protect industrial and commercial electrical circuits against overloads and short-circuit faults.

What is the rated current of this breaker?

The ABB 1SDA060226R1 has a rated current of 630 A.

What type of trip unit is fitted?

This breaker is equipped with a PR221DS-LS/I electronic release providing long-time, short-time and instantaneous protection.

How many poles does this circuit breaker have?

The ABB 1SDA060226R1 is supplied as a three-pole fixed circuit breaker.

Where is this breaker typically installed?

It is commonly installed in switchboards, industrial distribution panels, feeder circuits and OEM electrical equipment.

Trusted by Electrical Professionals Worldwide

ABB Tmax moulded case circuit breakers are trusted worldwide by panel builders, OEMs and electrical engineers for dependable protection, advanced electronic trip technology and long-term reliability in industrial power distribution.