1sda060106r1  t4h 250 ul/csa tmd 30-500 4 pole abb mccb

1sda060106r1 t4h 250 ul/csa tmd 30-500 4 pole abb mccb

ABB 1SDA060106R1 SACE Tmax T4H250 UL/CSA four-pole moulded case circuit breaker with TMD thermomagnetic release and 30 to 500 A magnetic trip range for low voltage power distribution systems.

SKU: 1SDA060106R1Alt SKU: T4H 250UL/CSA TMD 30-500 4p F FMPN: 1SDA060106R1
Price on application Contact us for pricing and availability.
Call 01708 343600

Why Choose the ABB 1SDA060106R1 Moulded Case Circuit Breaker?

The ABB 1SDA060106R1 is a robust SACE Tmax T4H250 UL/CSA moulded case circuit breaker (MCCB) designed to provide dependable protection for low voltage electrical distribution systems. Built for industrial panels, commercial switchboards and OEM machinery, it delivers reliable overload and short circuit protection in demanding electrical environments.

Part of the proven ABB SACE Tmax T4H250 series, this model features a four-pole fixed configuration with front terminals and a TMD thermomagnetic trip unit. The thermal and magnetic protection functions help protect electrical circuits against sustained overloads and high fault currents, supporting safe and reliable operation.

With a 250 A frame size and a 30 to 500 A magnetic trip range, the ABB 1SDA060106R1 is suitable for three-phase plus neutral electrical systems requiring UL/CSA compliant circuit protection. Its fixed front-terminal design supports straightforward installation into control panels and low voltage distribution assemblies.

Key Advantages

  • High quality ABB SACE Tmax T4H250 moulded case circuit breaker.
  • TMD thermomagnetic trip unit for overload and short circuit protection.
  • Four-pole fixed design for three-phase plus neutral electrical systems.
  • Front terminal connections for straightforward panel installation.
  • Suitable for industrial switchboards, machinery and distribution systems.
  • UL / CSA compliant version for international and export applications.

Key Features

  • ABB SACE Tmax T4H250 series.
  • Product code: 1SDA060106R1.
  • Four-pole moulded case circuit breaker.
  • Fixed mounting configuration.
  • Front terminal connections.
  • TMD thermomagnetic release.
  • 30 to 500 A magnetic protection range.
  • UL / CSA compliant version.

Reliable Protection for Low Voltage Distribution Systems

The thermomagnetic release combines thermal overload protection with magnetic short circuit protection, making the ABB 1SDA060106R1 suitable for a wide range of electrical distribution and machinery applications. This helps protect cables, equipment and downstream circuits from damaging fault conditions.

The four-pole construction allows protection and isolation of three-phase plus neutral systems, making this MCCB a practical option for industrial switchboards, OEM control panels and commercial electrical distribution boards.

Typical Applications

  • Industrial power distribution switchboards.
  • Commercial electrical distribution panels.
  • Three-phase plus neutral electrical circuits.
  • OEM machinery and control panels.
  • Main and sub-distribution boards.
  • Manufacturing and process plant electrical systems.

Technical Specifications

Tick the specs you need, then view products that match.

Current 30 A
Phase Three Phase
Poles 4-pole
Device Type MCCB
Trip Unit Thermal-magnetic
Manufacturer ABB
Series SACE Tmax T4H250
Model 1SDA060106R1
Alternative reference T4H250 UL/CSA TMD 30-500 4p F F
Product type Moulded case circuit breaker
Frame size T4 250
Number of poles 4
Mounting type Fixed
Terminal type Front terminals
Trip unit TMD thermomagnetic release
Magnetic trip range 30 to 500 A
Rated operational voltage Up to 690 V AC
Rated insulation voltage 1000 V
Rated impulse withstand voltage 8 kV
Standards UL / CSA
Protection Overload and short circuit

Frequently Asked Questions

What is the ABB 1SDA060106R1 used for?

It is used to provide overload and short circuit protection for low voltage electrical distribution systems, switchboards and industrial control panels.

What type of trip unit is fitted?

The ABB 1SDA060106R1 is fitted with a TMD thermomagnetic trip unit for overload and short circuit protection.

How many poles does this MCCB have?

This model is a four-pole moulded case circuit breaker, suitable for three-phase plus neutral electrical systems.

What is the magnetic trip range?

The ABB 1SDA060106R1 has a 30 to 500 A magnetic trip range, depending on the protection setting and application requirements.

Is this circuit breaker suitable for UL/CSA applications?

Yes, this model is a UL / CSA version, making it suitable for compliant machinery, control panel and industrial applications.

Trusted by Electrical Professionals Worldwide

ABB SACE Tmax moulded case circuit breakers are trusted by panel builders, electrical contractors and industrial engineers worldwide for dependable protection, robust construction and long service life in demanding low voltage installations.