1sda059463r1  t5s 400mcp-ul csa pr221ds-i in=400 3 pole abb mccb

1sda059463r1 t5s 400mcp-ul csa pr221ds-i in=400 3 pole abb mccb

ABB 1SDA059463R1 Tmax T5S 400 A three-pole motor circuit protector with PR221DS-I electronic magnetic release, fixed front terminals and UL/CSA configuration for low voltage motor and feeder protection.

SKU: 1SDA059463R1Alt SKU: T5S400 MCP-UL/CSA PR221DS-I In=400 3p FFMPN: 1SDA059463R1
Price on application Contact us for pricing and availability.
Call 01708 343600

Why Choose the ABB 1SDA059463R1 Tmax T5S Motor Circuit Protector?

The ABB 1SDA059463R1 is a high-performance Tmax T5S motor circuit protector designed for dependable short-circuit protection in low voltage motor control and electrical distribution systems. Part of the trusted ABB SACE Tmax T series, this breaker is built for industrial switchboards, motor control centres, OEM machinery and control panel applications requiring robust protection and reliable ABB performance.

This model features a PR221DS-I electronic magnetic release, providing instantaneous protection against short-circuit faults. Its UL/CSA configuration supports installations requiring North American approval standards, while the fixed three-pole design with front terminals allows straightforward integration into switchboards, feeder panels and motor starter assemblies.

With a 400 A rated current, 400 A frame rating and 600 V AC rated operational voltage, the ABB 1SDA059463R1 is ideal for high-current motor protection and feeder applications where compact construction, dependable fault interruption and long-term reliability are essential.

Key Advantages

  • Reliable ABB Tmax T5S motor circuit protector for industrial applications.
  • 400 A rated current with a 400 A frame size.
  • PR221DS-I electronic magnetic release for instantaneous protection.
  • Three-pole fixed breaker with front terminal connections.
  • UL/CSA approved configuration for compliant installations.
  • Suitable for motor control centres, switchboards, machinery and OEM panels.

Key Features

  • ABB SACE Tmax T5S series.
  • Product code: 1SDA059463R1.
  • Rated current: 400 A.
  • Rated uninterrupted current: 400 A.
  • Three-pole fixed circuit breaker.
  • PR221DS-I electronic magnetic release.
  • 600 V AC rated operational voltage.
  • Fixed front terminal connection for switchboard installation.

Reliable Motor Circuit Protection for Industrial Systems

Motor circuit protectors such as the ABB Tmax T5S MCP provide rapid disconnection during short-circuit conditions, helping protect cables, switchgear and connected equipment. When used within a correctly designed motor starter assembly, they support safe and dependable operation in demanding industrial environments.

The PR221DS-I release provides instantaneous magnetic protection for motor control and feeder circuits. Its fixed construction and front terminal layout make the ABB 1SDA059463R1 a practical choice for panel builders, machine manufacturers and engineers working with high-current low voltage assemblies.

Typical Applications

  • Motor control centres.
  • Industrial switchboards and control panels.
  • OEM machinery and automation equipment.
  • Motor starter assemblies.
  • Feeder and sub-distribution circuit protection.
  • Installations requiring UL/CSA compliant circuit protection.

Technical Specifications

Tick the specs you need, then view products that match.

Current 400 A
Phase Three Phase
Poles 3-pole
Device Type MCCB
Trip Unit Electronic
Manufacturer ABB
Series SACE Tmax T5S
Model 1SDA059463R1
Extended product type T5S400 MCP-UL/CSA PR221DS-I In=400 3p FF
Product type Motor circuit protector / moulded case circuit breaker
Frame size T5
Rated current (In) 400 A
Rated uninterrupted current (Iu) 400 A
Number of poles 3P
Release PR221DS-I
Release type Electronic magnetic release
Rated operational voltage 600 V AC
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 8 kV
Terminal connection Fixed front terminals
Mechanical durability 20,000 cycles
Power loss 16.5 W per pole at rated operating conditions
EAN 8015644618452
Standards UL / CSA
Dimensions (H × W × D) approx. 205 × 140 × 103.5 mm
Weight approx. 5.1 kg

Frequently Asked Questions

What is the ABB 1SDA059463R1 used for?

The ABB 1SDA059463R1 is used for short-circuit protection in motor control, feeder and low voltage electrical distribution applications.

What is the rated current of this motor circuit protector?

This model has a 400 A rated current and is built on a 400 A Tmax T5 frame.

What trip unit is fitted to the ABB 1SDA059463R1?

It is fitted with a PR221DS-I electronic magnetic release, providing instantaneous protection against short-circuit faults.

How many poles does this breaker have?

The ABB 1SDA059463R1 is a three-pole fixed breaker with front terminal connections.

Is the ABB 1SDA059463R1 suitable for UL/CSA installations?

Yes, this version is designed for UL/CSA applications, making it suitable for installations where those approval standards are required.

Trusted by Electrical Professionals Worldwide

ABB Tmax motor circuit protectors and moulded case circuit breakers are widely used by panel builders, machine manufacturers and industrial engineers for reliable low voltage protection, durable construction and trusted performance in demanding installations.