1SDA059402R1 ABB E3S1000 PR122/P-LSI 1000A 3-Pole Withdrawable Air Circuit Breaker

1SDA059402R1 ABB E3S1000 PR122/P-LSI 1000A 3-Pole Withdrawable Air Circuit Breaker

ABB 1SDA059402R1 E3S1000 is a 1000 A three-pole withdrawable SACE Emax air circuit breaker moving part with a PR122/P-LSI R1000 electronic trip unit providing adjustable overload and short-circuit protection.

SKU: 1SDA059402R1MPN: 1SDA059402R1
Price
List Price £11,523.44 ex VAT
Your Price (ex VAT) Save 25%
£8,642.58 25% OFF
You save £2,880.86 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £8,642.58
Trade pricing is personalised to your account

Manufacturer Lead Time

£8,642.58

Why Choose the ABB E3S1000 PR122/P-LSI 1000A 3-Pole Withdrawable Air Circuit Breaker?

The ABB E3S1000 PR122/P-LSI, order code 1SDA059402R1, is a high-performance 1000 A three-pole withdrawable air circuit breaker moving part designed for switching and protecting demanding low-voltage power distribution systems. As part of the proven ABB SACE Emax E3S series, it combines high-current switching capability with advanced electronic overcurrent protection for industrial, commercial and infrastructure switchgear.

This Emax circuit breaker is equipped with the PR122/P-LSI R1000 electronic trip unit, providing long-time overload (L), short-time short-circuit (S) and instantaneous short-circuit (I) protection. Its adjustable electronic protection functions help safeguard cables, busbars, transformers, switchgear and connected equipment while supporting selective and coordinated protection throughout the electrical distribution system.

With a rated uninterrupted current of 1000 A, rated operational voltage of 690 V AC and rated ultimate and service short-circuit breaking capacities of 75 kA throughout the specified AC voltage range, the E3S1000 is engineered for demanding distribution duties. This model is supplied as the three-pole moving part of a withdrawable circuit breaker, allowing the breaker to be removed from its compatible fixed part for inspection, maintenance or replacement.

Key Advantages

  • Heavy-duty 1000 A air circuit breaker moving part for low-voltage power distribution.
  • Three-pole configuration for three-phase electrical systems.
  • PR122/P-LSI R1000 electronic trip unit provides adjustable LSI protection.
  • 75 kA rated ultimate short-circuit breaking capacity at 400/415 V AC.
  • 75 kA rated service short-circuit breaking capacity at 400/415 V AC.
  • 75 kA short-time withstand current for 1 s.
  • Withdrawable moving-part construction supports efficient servicing and breaker replacement.
  • High 1000 V insulation voltage and 12 kV impulse withstand voltage.
  • Part of the established ABB SACE Emax air circuit breaker platform.

Key Features

  • ABB SACE Emax E3S air circuit breaker moving part.
  • 1000 A rated current.
  • Three-pole construction.
  • PR122/P-LSI R1000 electronic overcurrent release.
  • Long-time overload protection (L).
  • Short-time short-circuit protection (S).
  • Instantaneous short-circuit protection (I).
  • Withdrawable version / moving part (W MP).
  • 690 V AC rated operational voltage.
  • 1000 V rated insulation voltage.
  • 12 kV rated impulse withstand voltage.
  • 75 kA Icu and Ics at 400/415 V AC.
  • 75 kA Icw for 1 s and 65 kA for 3 s.
  • Four auxiliary contacts with circuit-breaker open/closed position indication.

Reliable Circuit Protection for Power Distribution

Air circuit breakers such as the ABB SACE Emax E3S are designed to switch and protect high-current low-voltage distribution circuits. The PR122/P electronic trip unit monitors circuit current and initiates breaker operation when configured protection thresholds are exceeded, helping safeguard cables, busbars, transformers, switchgear and connected equipment against damaging overload and short-circuit conditions.

The PR122/P-LSI release combines adjustable long-time, short-time and instantaneous protection with the substantial short-circuit capability of the E3S frame. Combined with its three-pole withdrawable construction, the E3S1000 is particularly well suited to main and feeder protection where coordinated electronic protection, high fault-current performance and service-friendly breaker removal are required.

Typical Applications

  • Low-voltage main distribution switchboards.
  • Industrial power distribution systems.
  • Commercial building electrical distribution.
  • Manufacturing and process plant switchgear.
  • Transformer and feeder protection.
  • High-fault-current distribution systems.
  • Power distribution panels and switchgear assemblies.
  • Infrastructure and utility installations.
  • Protection of busbars and high-current distribution circuits.

Technical Specifications

Series SACE Emax
ABB order code 1SDA059402R1
EAN 8015644617639
Product group 310513-New Emax
Customs tariff number 85362090
Product type Air circuit breaker moving part
Frame / subtype E3
Short-circuit performance level S
Rated current (In) 1000 A
Rated uninterrupted current (Iu) 1000 A
Rated operational current (Ie) 1000 A
Number of poles 3
Current type AC
Rated operational voltage 690 V AC
Rated voltage (Ur) 690 V
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 12 kV
Trip unit PR122/P-LSI R1000
Release type Electronic
Protection functions L (long-time overload), S (short-time short-circuit) and I (instantaneous short-circuit)
Overload release adjustment range 400–1000 A
Short-time short-circuit release adjustment range 600–10000 A
Instantaneous short-circuit release adjustment range 1500–15000 A
Rated ultimate short-circuit breaking capacity (Icu) 75 kA at 220–690 V AC
Rated service short-circuit breaking capacity (Ics) 75 kA at 220–690 V AC
Rated short-time withstand current (Icw) 75 kA for 1 s; 65 kA for 3 s
Version Withdrawable moving part
Terminal connection type Withdrawable circuit breaker
Auxiliary contacts 4
Position indication Circuit breaker open / closed
Power loss 57.6 W
Mechanical durability 20,000 operating cycles
Mechanical operating frequency 60 cycles per hour
Electrical durability 12,000 operating cycles at ≤440 V; 12,000 operating cycles at 500–690 V
Electrical operating frequency 20 cycles per hour
Dimensions (W × H × D) 432 × 461 × 396.5 mm
Net weight 64 kg
Standard IEC

Frequently Asked Questions

What is the ABB 1SDA059402R1 used for?

The ABB 1SDA059402R1 is a 1000 A three-pole SACE Emax air circuit breaker moving part designed for switching and protecting demanding high-current low-voltage electrical distribution circuits.

What trip unit is fitted to the ABB E3S1000 1SDA059402R1?

This circuit breaker is equipped with the ABB PR122/P-LSI R1000 electronic trip unit, providing adjustable long-time overload, short-time short-circuit and instantaneous short-circuit protection.

What is the short-circuit breaking capacity of the ABB E3S1000?

The E3S1000 1SDA059402R1 provides rated ultimate and service short-circuit breaking capacities of 75 kA throughout the specified 220–690 V AC range.

Is the ABB 1SDA059402R1 fixed or withdrawable?

The 1SDA059402R1 is the moving part of a three-pole withdrawable air circuit breaker, designed for use with the appropriate compatible ABB SACE Emax fixed part.

What does LSI protection mean on the ABB E3S1000?

LSI denotes long-time overload (L), short-time short-circuit (S) and instantaneous short-circuit (I) protection, providing coordinated electronic protection against overloads and short-circuit faults.

Trusted ABB Power Distribution Technology

ABB SACE Emax air circuit breakers are engineered for dependable low-voltage power distribution, combining high short-circuit performance, adjustable electronic protection and service-friendly withdrawable construction for demanding industrial and commercial switchgear.