1SDA059362R1 ABB E3H1000 PR122/P-LSI 1000A 3-Pole Withdrawable Air Circuit Breaker

1SDA059362R1 ABB E3H1000 PR122/P-LSI 1000A 3-Pole Withdrawable Air Circuit Breaker

ABB 1SDA059362R1 E3H1000 is a 1000 A three-pole withdrawable SACE Emax air circuit breaker moving part with a PR122/P-LSI R1000 electronic trip unit providing adjustable overload and short-circuit protection.

SKU: 1SDA059362R1MPN: 1SDA059362R1
Price
List Price £12,567.82 ex VAT
Your Price (ex VAT) Save 25%
£9,425.87 25% OFF
You save £3,141.96 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £9,425.87
Trade pricing is personalised to your account

Manufacturer Lead Time

£9,425.87

Why Choose the ABB E3H1000 PR122/P-LSI 1000A 3-Pole Withdrawable Air Circuit Breaker?

The ABB E3H1000 PR122/P-LSI, order code 1SDA059362R1, is a high-performance 1000 A three-pole withdrawable air circuit breaker moving part designed for switching and protecting demanding low-voltage power distribution systems. As part of the proven ABB SACE Emax E3H series, it combines substantial short-circuit performance with electronic overcurrent protection for industrial, commercial and infrastructure switchgear.

This Emax circuit breaker is equipped with the PR122/P-LSI R1000 electronic trip unit, providing long-time overload (L), short-time short-circuit (S) and instantaneous short-circuit (I) protection. Its adjustable protection settings help safeguard cables, busbars, transformers, switchgear and connected equipment while supporting selective and coordinated protection throughout the electrical distribution system.

With a rated uninterrupted current of 1000 A, rated operational voltage of 690 V AC and an ultimate short-circuit breaking capacity of 100 kA at 400/415 V AC, the E3H1000 is engineered for installations with demanding prospective fault currents. This model is supplied as the three-pole moving part of a withdrawable circuit breaker and includes four auxiliary contacts with circuit-breaker open/closed position indication.

Key Advantages

  • Heavy-duty 1000 A air circuit breaker moving part for demanding low-voltage distribution systems.
  • Three-pole configuration for three-phase electrical circuits.
  • PR122/P-LSI R1000 electronic trip unit provides adjustable LSI protection.
  • 100 kA ultimate short-circuit breaking capacity at 400/415 V AC.
  • 85 kA service short-circuit breaking capacity at 400/415 V AC.
  • 75 kA short-time withstand current for 1 s.
  • Withdrawable construction supports efficient inspection, servicing and breaker replacement.
  • Four auxiliary contacts with open/closed circuit-breaker position indication.
  • Part of the established ABB SACE Emax air circuit breaker platform.

Key Features

  • ABB SACE Emax E3H air circuit breaker moving part.
  • 1000 A rated current.
  • Three-pole construction.
  • PR122/P-LSI R1000 electronic overcurrent release.
  • Long-time overload protection (L).
  • Short-time short-circuit protection (S).
  • Instantaneous short-circuit protection (I).
  • Withdrawable version / moving part (W MP).
  • 690 V AC rated operational voltage.
  • 1000 V rated insulation voltage.
  • 12 kV rated impulse withstand voltage.
  • Four auxiliary contacts.
  • Circuit-breaker open/closed position indication.
  • Optional motor drive capability.

Reliable Circuit Protection for Power Distribution

Air circuit breakers such as the ABB SACE Emax E3H are designed to switch and protect high-current low-voltage distribution circuits. The PR122/P electronic trip unit monitors circuit current and initiates breaker operation when configured protection thresholds are exceeded, helping safeguard cables, busbars, transformers, switchgear and connected equipment against damaging overload and short-circuit conditions.

The PR122/P-LSI release combines adjustable long-time, short-time and instantaneous protection with the substantial short-circuit performance of the E3H frame. Combined with its withdrawable construction, the E3H1000 is particularly well suited to main and feeder protection where high fault-current capability, selective coordination and service-friendly breaker removal are important.

Typical Applications

  • Low-voltage main distribution switchboards.
  • Industrial power distribution systems.
  • Commercial building electrical distribution.
  • Manufacturing and process plant switchgear.
  • Transformer and feeder protection.
  • High-fault-level distribution systems.
  • Power distribution panels and switchgear assemblies.
  • Infrastructure and utility installations.
  • Protection of busbars and high-current distribution circuits.

Technical Specifications

Series SACE Emax
ABB order code 1SDA059362R1
EAN 8015644617233
Product group 310513-New Emax
Customs tariff number 85362090
Product type Air circuit breaker moving part
Frame / subtype E3
Short-circuit performance level H
Rated current (In) 1000 A
Rated uninterrupted current (Iu) 1000 A
Rated operational current (Ie) 1000 A
Number of poles 3
Current type AC
Rated operational voltage 690 V AC
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 12 kV
Trip unit PR122/P-LSI R1000
Release type Electronic
Protection functions L (overload), S (short-time short-circuit) and I (instantaneous short-circuit)
Overload release adjustment range 400–1000 A
Short-time short-circuit release adjustment range 600–10000 A
Instantaneous short-circuit release adjustment range 1500–15000 A
Rated ultimate short-circuit breaking capacity (Icu) 100 kA at 220–500 V AC; 85 kA at 660–690 V AC
Rated service short-circuit breaking capacity (Ics) 85 kA at 220–690 V AC
Rated short-time withstand current (Icw) 75 kA for 1 s; 65 kA for 3 s
Version Withdrawable moving part
Terminal connection type Withdrawable circuit breaker
Auxiliary contacts 4
Position indication Circuit breaker open / closed
Motor drive Optional
Integrated motor drive No
Power loss 57.6 W
Mechanical durability 20,000 operating cycles
Mechanical operating frequency 60 cycles per hour
Electrical durability 12,000 operating cycles at ≤690 V
Electrical operating frequency 20 cycles per hour
Dimensions (W × H × D) 432 × 461 × 396.5 mm
Net weight 64 kg
Standard IEC

Frequently Asked Questions

What is the ABB 1SDA059362R1 used for?

The ABB 1SDA059362R1 is a 1000 A three-pole SACE Emax air circuit breaker moving part designed for switching and protecting demanding high-current low-voltage electrical distribution circuits.

What trip unit is fitted to the ABB E3H1000 1SDA059362R1?

This circuit breaker is equipped with the ABB PR122/P-LSI R1000 electronic trip unit, providing adjustable long-time overload, short-time short-circuit and instantaneous short-circuit protection.

What is the short-circuit breaking capacity of the ABB E3H1000?

The E3H1000 provides a rated ultimate short-circuit breaking capacity of 100 kA at 400/415 V AC and a rated service short-circuit breaking capacity of 85 kA.

Is the ABB 1SDA059362R1 fixed or withdrawable?

The 1SDA059362R1 is the moving part of a three-pole withdrawable air circuit breaker, designed for use with the appropriate compatible SACE Emax fixed part.

What does LSI protection mean on the ABB E3H1000?

LSI denotes long-time overload (L), short-time short-circuit (S) and instantaneous short-circuit (I) protection, providing coordinated electronic protection against overloads and short-circuit faults.

Trusted ABB Power Distribution Technology

ABB SACE Emax air circuit breakers are engineered for dependable low-voltage power distribution, combining high short-circuit performance, adjustable electronic protection and service-friendly withdrawable construction for demanding industrial and commercial switchgear.